To get above 50 psi, momentarily push 1. INTRODUCTION the "INC" button (the buttons override the The Electro Governor is an automatic automatic mode whenever they are control system that constantly measures pushed). The Governor will now advance the pump pressure (using the transducer), to the desired pressure.
Page 3
If chain is used as the interconnection, increase and decrease switches to check be careful it is not the type of chain that the travel and stops. In the MANUAL and can loop on itself, and make sure it cannot in the AUTO mode, when the "INC"...
draft, etc. Adjustment Procedure Step B. The Governor is reacting slowly There are two adjustments on the (on increase). Turn Potentiometer "Fast control box. In the factory they are set Increase" in small steps clockwise until approximately at the half-way points. the response is satisfactory.
speed remains at that RPM. MANUAL position, by pushing the appropriate buttons. If the fuse is blown, the increase and decrease buttons will still operate. If the increase and decrease buttons are pushed 4. Trouble-Shooting simultaneously, the decrease button will control the system.
5. SPECIFICATIONS CONTROL 7 sec. maximum Response : Idle to full throttle Pressure Recovery : On open/close values 3 sec. typical Pressure dial range : 0-300 PSI Minimum discharge pressure control point : 50 PSI ( out of water, engine is returned to idle ) ELECTRICAL Power 12 VDC or 24 VDC optional...