1. Introduction............................................................................................ 1
2. Specifications.......................................................................................... 1
3. Symbol Definition and Button Location............................................................... 2
4. Operation Instructions................................................................................... 3
4.1 Power-Up..........................................................................................................3
4.2 Connection the Temperature Probe................................................................... 3
4.3 Selecting the Temperature Scale............................................................. 3
4.4 READ Operation.................................................................................. 3
4.5 Back light Operation............................................................................. 3
4.6 Relative Operation................................................................................. 3
4.7 Memory Operation.................................................................................. 3
4.8 MAX/MIN Operation................................................................................ 3
4.9 Auto Power Off.................................................................................... 4
4.10 Low Battery Condition.................................................. ....................... 4
5. Temperature Measurement................................................. ....................... 4
6. Setting the Time.......................................................................................... 5
7. Clearing Memory..................................................................................... 5
8. Temperature Meter Calibration Setup ......................................................... 6
9. Power Preparation.................................................................................... 7
10. Maintenance ......................................................................................... 7
11. Temperature Probe.................................................................................. 8
CONTENTS
PAGE

Advertisement

Table of Contents
loading

Summary of Contents for Precision RTD

  • Page 1: Table Of Contents

    CONTENTS TITLE PAGE 1. Introduction………………………………………………………………….……………. 1 2. Specifications……………………………………………………………………………... 1 3. Symbol Definition and Button Location………............2 4. Operation Instructions……………………….…………………........3 4.1 Power-Up……………...................3 4.2 Connection the Temperature Probe………............3 4.3 Selecting the Temperature Scale……………..…………………………………….. 3 4.4 READ Operation…………………………………………………………………..….. 3 4.5 Back light Operation………………………………………………………………….. 3 4.6 Relative Operation……………………………………………………………....
  • Page 2: Introduction

    RTD THERMOMETER 1. INSTRUCTION This instrument is a digital thermometer for use with platinum-type temperature sensor. Temperature indication follows IEC751 temperature table for PT-type sensor. 2. SPECIFICATIONS Numerical Display: 5 digital liquid crystal displays Measurement Range: -100°C ~ 400°C; -148°F ~ 752°F Resolution: 0.01°C;...
  • Page 3: Symbol Definition And Button Location

    RTD THERMOMETER 3. SYMBOL DEFINITION & BUTTON LOCATION : The Battery is not sufficient for proper operation. : The Minimum value is now being displayed MAX : The Maximum value is now being displayed : This indicates Auto Power Off is enabled.
  • Page 4: Operation Instructions

    RTD THERMOMETER 4. OPERATION INSTRUCTIONS 4.1 Power-Up Press the “ ” key to turn ON the thermometer and Press and hold “ ” buttons for 3 seconds to OFF. 4.2 Connection the Temperature Probe For measurement, plug the temperature probe into the input connectors.
  • Page 5: Auto Power Off

    RTD THERMOMETER Press button again, MAX and MIN will blink together. This means that all these data is updated in the memory and the reading is the present temperature. One may press to circulate the display mode among these options.
  • Page 6: Setting The Time

    RTD THERMOMETER 6. SETTING THE TIME Press and hold button and then power on the meter to enter setup mode. Press button to enter Time setting mode. The right two digits blink. ▲ or ▼ button until the display shows the correct year, and then press Press button to select.
  • Page 7: Temperature Meter Calibration Setup

    RTD THERMOMETER 8. TEMPERATURE METER CALIBRATION SETUP Below table diagram shows each button function when user enter into calibration mode. Note: Turn the Power “OFF” before attempting following SETUP. Setup mode is cancelled during below procedure if “POWER” button is pressed.
  • Page 8: Power Preparation

    RTD THERMOMETER button to confirm revert back to “Default factory setting value” Press Press button to confirm selection. Note: To abort during the process, press button to exit calibration mode. 9. POWER PREPARATION 9.1 Battery Loading Remove the battery cover on the back and insert one 9V battery.
  • Page 9: 11. Temperature Probe

    RTD THERMOMETER 11. Temperature Probe 11.1 Piercing type temperature probe. 11.2 Piercing type temperature probe Specification: Sensor Type Platinum resistance thermometer sensor Pt 100(4 wires) IEC751, class A 0.15C0.002t Accuracy (t: measurement temperature) Measurement Range -100 to 400C Approx. 5.0mm(0.2”)

Table of Contents