Scotsman NM950 Manual page 18

Table of Contents

Advertisement

NM950
MAINTENANCE: Air Cooled
///////////////////////////WARNING/////////////////////////////
Disconnect electrical power before
beginning.
//////////////////////////////////////////////////////////////////////////
5. Clean the air cooled condenser.
The air flow on this model is from front to
back, so the inside of the machine will have to
be available to clean the air cooled
condenser. Use a vacuum cleaner or coil
cleaner if needed. Do NOT use a wire brush.
A. Disconnect electrical power, and remove
the filter. The filter may be cleaned or replaced.
Step 1: Remove
top panel.
Step 3. Pull fan motor assembly off of locating
pins and out of the unit.
B. Clean the condenser: the condenser may
appear to be clean on the surface, but it can
still be clogged internally. Check with a flash
light from the front to see if light can be seen
though the condenser fins.
Step 2. Remove two screws and
unplug the fan motor assembly.
March, 1989
Page 18
Reverse to reassemble.