One (1) year from the date of installation by the original purchaser (“Warranty”). If such a defect is determined by Chore-Time to exist within the applicable period, Chore-Time will, at its option, (a) repair the Product or Component Part free of charge, F.O.B. the factory of manufacture or (b) replace the Product or Component Part free of charge, F.O.B.
Pneumatic Drinking System (PDS) Control About This Manual About This Manual The intent of this manual is to help you in two ways. One is to follow step-by-step in the order of assembly of your product. The other way is for easy reference if you have questions in a particular area.
Product Configurations The Chore-Tronics 3 Auto Adjust PDS™ Control (Part No. 56039-X) is available in 4, 8, 16, and 32 Station. The 12-40 PDS Controls (Part No.54373-X) are available up to 40 Stations in station increments of 4 (ie.
System Layout System Layout Multiple House Layout Air can be run from a central location to supply multiple houses. Air lines can consist of Chore-Time tubing (Part number 45895-500), which will supply a sufficient air supply, or PVC plumbing. Control...
System Layout Pneumatic Drinking System (PDS) Control Layer System Layout One Water Line Per Tier, One Regulator Per Tier nector Tee Regulator o. 45894) ubing 895) Figure 3.One Line/One Regulator Two Water Lines per Tier, Two Regulators Per Tier Connector Tee (Part No.
Pneumatic Drinking System (PDS) Control System Layout ® ™ Two Lines Per Tier, One Regulator Per Tier (Versa Plus and Vike Systems) Regulator Tubing art No. 45895) 1/4" PDS Connector Te (Part No. 45894) ® Figure 5.Versa Plus and Vike...
Pressure Sensor location (for 56039-X PDS Systems) ™ ™ There should be one Pressure Sensor installed per PDS Control. The Pressure Sensor should be installed close to a Stand Tube, preferably no more than one Nipple Pipe away. This will help ensure an accurate reading.
Figure 8.Chore-Tronics 3 PDS Mounting 4 and 8 Station (52430-X) PDS™ Control Mounting Locate the control in a convenient location where it can easily be seen and adjusted. Fasten the control to the wall through the four holes in the corners with #10 Flat Head Wood Screws. (Not Supplied) 31"...
• One (1) PDS™ Control - 2 gallon minimum recommended air supply tank. • Two (2) - four (4) PDS™ Controls - 5 gallon minimum recommended air supply tank. • Five (5) - six (6) PDS™ Controls - 10 gallon minimum recommended air supply tank.
Plus and Vike Systems with two pipes per tier Chore-Time recommends two regulators per station of the PDS control split between two cage rows as shown in Figure 5. to prevent overfill of the drain when flushing. Each Station may be used to supply air to two regulators. Controlling (55837) more than 2 regulators per station may overdraw water supply.
All electrical connections and wiring runs must be made according to local building codes. Note: No backup battery needed! All timer settings are stored indefinitely in memory. Note: Do Not move Relay Switches to "Manual" or "Auto" for the PDS Regulator Increase/Decrease until you have checked all the PDS Settings and finished the Startup section on page 20.
Installation Pneumatic Drinking System (PDS) Control Pressure Sensor Wiring The Pressure Sensor can be connected to any one of the Analog Inputs on the CT3 I/O Board. Jumper in the "I" position AI11 AI10 Black Figure 17.Pressure Sensor Wiring MW2467B...
24VAC Coil Relay (not supplied), from the relay run the two wires to the Chore-Tronics control, (See Figure 18.) Chore-Time has a 3 pole (only one pole is needed), 24 Volt relay available. (Part No. 56577-24) Figure 18. Rain Bird/Chore-Tronics Wiring Internal Wiring Figure 19.
Control. Number 1 on the first RainBird Module will be connected to the number 1 on the PDS Control. This will be repeated until all the module terminals are connected to the PDS Terminals. ® Note: "Valve" in the RainBird Manual is the "Solenoid Connection"...
® 24VAC Coil Relay (not supplied), from the relay run the two wires to the Chore-Tronics Control, (See Figure 21.). Chore-Time has a 3 pole (only one pole is needed), 24 Volt relay available. (Part No. 56577-24) ® ® Figure 21.RainBird...
Step 2: Water Column Gauge Calibration (52430-X, & 54373-X PDS Control Models) •Using the PDS Control Adjustment Knob (See Figure 11. on page 12), bring the line to 14" water col- umn as measured at regulator stand tube. •Pop off plastic cover and turn calibration screw till arrow points to 14" (See Figure 22.). Re-attach Cover.
101.3 Liters Liters of water in one meter of 3/4" (1.90 cm) Chore-Time water pipe=.422 Estimated flush times above are to completely exchange the water in the pipe. The water line length must include the length of the supply line from the water source to completely exchange the water. The flush time to stimulate bird drinking may be less, depending on the frequency of flushes.
1.In periods of hot weather flushing will provide cool, fresh water. 2.As birds mature, additional flushing can stimulate the birds to drink more water. Flushing 4 and 8 Station (52430-X) PDS™ Refer to the Rain Bird Timer manual for specific programing details.
When birds go out it is a good idea to turn the Rain Bird Control to the off position ® and turn the adjustment knob on the PDS Control to the minimum setting. Each program can have up to eight daily start times. As long as there are start times entered for stations in a particular program that program will run.
Chore-Tronics® 3 (56039-X) PDS™ Setup Screens & Operation Pneumatic Drinking System (PDS) Control ™ Chore-Tronics 3 (56039-X) PDS Setup Screens & Operation ® Attention! Refer to the Chore-Tronics 3 Manual MT2398 to learn about how to navigate screens of the Chore- Tronics 3 Control.
Pneumatic Drinking System (PDS) Control Chore-Tronics® 3 (56039-X) PDS™ Setup Screens & Operation Flushing 1.Number of Stations 2.Enter the time of Flush 3.Run Time per Station Regulator Set Point Edit the Regulator Set Point. The increase or Decrease Relay will turn on and off until the setting is reached.
Maintenance Pneumatic Drinking System (PDS) Control Maintenance •Keep the control box lid closed. The control is not capable of operating in a dusty environment. The loading regulator vents into the control box. When the control box is closed, the positive internal air pressure keeps dust out.
TroubleShooting Problem Correction 1. Water Off. No water in Stand Tube. 2. Defective or plugged Regulator. 3. Regulator plumbed backwards. 4. Stand Tube Cap plugged (not venting). 1. Stand Tube Cap plugged (not venting). Water Column does not change. 2. Air line to Regulator pinched. Regulator seat worn or foreign object in seat area.
Page 33
52430-4 52430-8 Item Description Part No Part No 120V Timer Control 52412-1 52412-2 Hinge 49482 49482 Water Column Gauge 44029 44029 Air Pressure Gauge 56095 56095 Control Plate 52411 52411 Control Decal 2529-939 2529-939 1/8" Female Pipe Adapter 48586 48586 Control Box (14 x 16) 52455 52455...
Page 35
® 4 Station Module 54372-4 8 Station Module 54372-8 12 Station Module 54372-12 Air Station Plug 55837 *These components are individually boxed. Contact your nearby Chore-Time distributor or representative for additional Rain Bird Control parts and ® information. 23 *...
Part Numbers Pneumatic Drinking System (PDS) Control Miscellaneous Parts Item Description Part No 1/8" PDS Tee Connector 45894 1/8" Coupling 45893 1/4" PDS Tubing 45895-500 24 Volt Relay 56577-24 MW2467B...
Page 37
Pneumatic Drinking System (PDS) Control Part Numbers This page left blank intentionally..MW2467B...
Page 38
Description of Change Various Combined PDS Manuals. Various Updates. 32501 Contact your nearby Chore-Time distributor or representative for additional parts and information. CTB Inc. P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A. Phone (574) 658-4101 • Fax (877) 730-8825...
Need help?
Do you have a question about the PDS and is the answer not in the manual?
Questions and answers