Download Print this page

ZIGBEE YALE-852-Ultra Introduction

Pir motion sensor camera

Advertisement

Quick Links

YALE-852-Ultra PIR Motion Sensor Camera
Introduction
YALE-852-ULTRA is a ZigBee passive infrared (PIR) motion sensor camera. It is capable of sending
wireless signals and captured images (picture quality of up to 640 x 480 pixels) to the coordinator in the
ZigBee network upon movement detection.
The PIR Camera is designed to give a typical detection range of 12 meters when mounted at 2 meters
above ground. It consists of a two-part design made up by a cover and a base. The cover contains all
the electronics, optics and camera, and the base provides a means of fixing. The base has knockouts to
allow mounting on either a flat surface or in a corner. The PIR Camera also has tamper protections
switch which will be activated upon any attempt of unauthorized cover opening.
The PIR Camera utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless
communication protocol that is reliable and has low power consumption and high transmission efficiency.
Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a
network and coordinated for data exchange and signal transmission
The PIR Camera serves as an end device in the ZigBee network. It can be included in the ZigBee
network to transmit signal upon activation, but cannot permit any other ZigBee device to join the
network through the PIR.
Parts Identification
1. Blue LED/Function Button
LED Indication:
The Blue LED lights up in the following conditions:
- The Blue LED flash once every 20 minutes
The PIR Camera has lost connection to its current ZigBee
network.
- The Blue LED lights up for 30 seconds:
The PIR Camera is warming up when fault(s) exists in the PIR
Camera.
- The Blue LED flashes twice quickly:
The PIR Camera has successfully joined a ZigBee network
after factory reset.
- The Blue LED lights up for 2 seconds under normal operation:
The PIR Camera has detected a movement when fault(s)
exists in the PIR Camera.
- The Blue LED flashes rapidly
PIR Camera is transmitting pictures to the coordinator of the
ZigBee network when fault(s) exists in the PIR Camera.
- The Blue LED and Flash LED flash once
PIR Camera has been reset.
Function Button Usage:
- Press the button once to send a supervision signal.
- To reset the PIR Camera:
Press and hold the button for 10 seconds. Release the button
when both the Flash LED and the Blue LED flash once
2. IR Sensor
The sensor is intended to detect moving objects.
3. Flash LED
The Flash LED delivers sufficient light for image capture under low
lighting condition.
Both the Flash LED and the Blue LED will flash once when the
Function Button is pressed for 10 seconds to indicate the PIR
Camera has been reset.
1

Advertisement

loading

Summary of Contents for ZIGBEE YALE-852-Ultra

  • Page 1 The PIR Camera serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal upon activation, but cannot permit any other ZigBee device to join the network through the PIR.
  • Page 2: Tamper Switch

    The PIR Camera features Low Battery Detection function. When the battery voltage is low, the PIR Camera will transmit Low Battery signal to the coordinator in ZigBee network. If movement is detected under Low Battery condition, the Blue LED will light up for 2 seconds.
  • Page 3 ⚫ ⚫ If the PIR Camera did not successfully join a ZigBee network upon power up, or if you want to remove the PIR Camera from the current network and join a new network, you need to use the Factory Reset function to clear the PIR Camera for its stored setting and information first before it can join another network.
  • Page 4: Installation

    If PIR Camera installation location is away from your system control panel and requires ZigBee routers to improve signal strength. DO NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down during AC power failure and the PIR Camera connected to the router will lose connection with ZigBee network.
  • Page 5 Appendix (For developers only) ⚫ ⚫ Device ID: _852_DEVICEID: 0x404 (proprietary) Endpoint: 0x01 Server Side Client Side Mandatory Basic (0x0000) None IAS Zone(0x0500) Optional _852_Cluster(0x0503) (proprietary) None ⚫ ⚫ Mandatory Identifier Name Type Range Access Default / Optional Unsigned Read 0x00 –0xff 0x0000 ZCLVersion...