Malfunction Management Unit Firmware Version 02.00.05 Operations Manual NEMA TS 2 Amendment 4-2012 Malfunction Management Unit 16 Configuration Types of Flashing Yellow Arrows This manual contains technical information for the MMU2-1600GE series Malfunction Management Unit pn 889-3819-00 Revision: April 2020...
Page 4
THE FOLLOWING PRODUCT WAS DESIGNED, INSPECTED, TESTED AND MANUFACTURED IN THE USA BY EBERLE DESIGN, INC. IN PHOENIX, ARIZONA. INFORMATION CONTAINED HEREIN IS PROPRIETARY TECHNICAL INFORMATION OF EBERLE DESIGN, INC. PUBLICATION, REPRODUCTION OR USE IN WHOLE OR PART IS NOT PERMITTED EXCEPT UNDER TERMS AGREED UPON IN WRITING. ALL REGISTERED TRADEMARKS OF EBERLE DESIGN INC.
MMU2-1600GE Series Operations Manual Table of Contents Section 1 General Description ..................1 Section 2 General Characteristics ................... 3 2.1 Inputs 3 2.1.1 AC Line ......................3 2.1.2 AC Neutral ....................3 2.1.3 Earth Ground ....................3 2.1.4 Field Terminals (Reds, Yellows, Greens, and Walks) ........3 2.1.5 Red Enable ....................
Page 7
2.5.11 Controller Voltage Monitor ................14 2.5.12 Local Flash ....................15 2.5.13 External Watchdog Monitoring ..............15 2.5.14 Programming Card Absent Monitoring ............16 2.6 Testing Modifiers ....................16 2.6.1 Flashing Don’t Walk Monitoring ..............16 2.6.2 PPLT5 Monitoring ..................16 2.6.3 Flashing Yellow Arrow Monitoring (FYA) ............16 2.6.4 LED Thresholds ...................17 2.6.5 Per Channel Red Enable................18 2.6.6 Modified CVM Latch ..................18...
Page 8
4.6.3.1 View Logs ...................43 4.6.3.2 Clear Logs ..................44 4.6.3.3 Clear All Logs ..................44 4.6.3.4 AC Logging Events Thresholds ............44 4.6.4 Date & Time Menu ..................45 4.6.4.1 View / Set Date and Time ..............45 4.6.4.2 View / Set Daylight Saving Time Ahead ..........45 4.6.4.3 View / Set Daylight Saving Time Back ..........45 4.6.4.4 View Up Time ..................45 4.6.5 Real Time Monitor Status Menu ..............45...
Likewise, the monitor receives information from the Controller Unit corresponding to Controller Unit output commands to the 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 1 of 51...
Page 11
Model MMU2-1600GE (Reno Canada) For applications calling for a NEMA TS 2-2003 compliant Malfunction Management Unit with integral graphics display and Canadian Fast Flash monitoring and optional Ethernet network connector. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 2 of 51...
89V at the Red Enable input. This function is considered not enabled when the input voltage is less than 70V at the Red Enable input. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 3 of 51...
Status bit (bit 79) in the Type 129 Frame to 1. At all other times, the Local Flash Status bit of the Type 129 Frame is set to 0. Typical Connection: Police Panel flash switch and/or inside cabinet flash switch 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 4 of 51...
Programming cards supplied by Reno A&E have an integral serial EEPROM which can store the other settings for the monitor which are not programmed using soldered jumpers. See Section 3.5 for programming card connector pin assignments. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 5 of 51...
Time Clock setting differs from the Controller Time setting by more than two (2) seconds, The Real Time Clock will be synchronized to the Controller clock. In the event that the Real Time Clock setting differs 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 7 of 51...
Test Preformed: While a channel has a Green, Walk, or Yellow display active, the channel is tested to see if a non-permissive channel has a Green, Walk, or Yellow display active at the same time. If concurrently active 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 8 of 51...
Power loss or power interruption will not reset this fault. The Reset log will record the resetting of this fault. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 9 of 51...
Load Switch Flash bit (bit 112) of the Type 0 Frame: All dual indication testing will be disabled when this bit is set to one. Feature Interactions: Field Check: Enabling dual indication monitoring will also enable field check monitoring. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 10 of 51...
2.7 seconds. When each Green turns off a 2.7 second timer is started. A Yellow must start within 1 second of the Green turning off. If the Red turns on before the Yellow, a short Yellow fault will be generated to show that 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 11 of 51...
INDICATION OFF, no MYCD jumper, and is not selected as a pedestrian channel then the unused indication (Green or Yellow) of the FYA channel is ignored for Short Clearance. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 12 of 51...
Port 1 Disable: Port 1 failures will be ignored when this input is below 8V Type Select: Port 1 failures will be ignored when this input is in the Type 12 mode (Unterminated or above Feature Interactions: None 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 13 of 51...
When the CVM input is detected as improper for more than 175 milliseconds, the monitor generates a fault. A CVM failure during the programmed Minimum Flash time or during a monitor Power Failure shall not cause a fault. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 14 of 51...
Power loss or power interruption will not reset this fault. The Reset log will record the resetting of this fault. Modifying Inputs: None 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 15 of 51...
Configuration: The Wizard configures 16 types of FYA left turn configurations. To manually set up FYA in the CONFIG SETTINGS MENU select the PERM LEFT (FYA) and FYA OPTIONS. PERM LEFT (FYA) 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 16 of 51...
Red Fail: Normal red fail testing senses Greens, Yellows, and Walks as ON when their voltage is above 25V and OFF when below 15V . Reds are ON when their voltage is above 70V and OFF when below 50V 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 17 of 51...
Configuration: The setting of 24V-2 to 12VDC determines if this feature is active. A low on the +24V Monitor Inhibit input inhibits the operation of the +12 Volt Monitor. The testing default for this feature is set to no. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 18 of 51...
2.7.1 TIME CHANGE LOG The Time Change Log records the 50 most recent time changes. Data recorded: Original Date / Time Stamp, New Date / Time Stamp, and Up Time Accumulator. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 19 of 51...
DSP Diagnostic 4000h The DSP is indicating that it has a diagnostic error. Error During the Boot 8000h The fault identified above was found during the boot process. Process 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 21 of 51...
False ......> +16 VDC : Meets and/or exceeds NEMA TS 2-2003 specifications. The monitor can be manually reset by depressing ESET the RESET pushbutton on the front panel. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 22 of 51...
Cabinet Interlock A Cabinet Interlock B Cabinet Interlock B Channel 14 Yellow Channel 6 Walk Channel 16 Green Channel 4 Walk Spare 2 Spare 2 Type Select Type Select 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 24 of 51...
Page 34
No Connection Not Used (Terminated) RX Data - No Connection Port 1 Disable (0 VDC = Disable) RX Clock - Earth Ground TX Data - Reserved TX Clock - 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 25 of 51...
Jumper Open Open Jumper Jumper Open Jumper Open Jumper Open Jumper Jumper Jumper Jumper Open Open Jumper Jumper Open Jumper Jumper Jumper Jumper Open Jumper Jumper Jumper Jumper 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 26 of 51...
ID Info Ethernet Settings Status DC Inputs Ethernet Port Stats DC Processor Com Stats Log View Config Pending Diag Stats SDLC Speed Stats Logging Thresholds Config Fault Location PC Factory 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 28 of 51...
HELP or ESCAPE pushbuttons to exit the help system. When a fault is displayed at the Run Time display, pressing the HELP pushbutton will display information about this type of fault and how to troubleshoot it. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 29 of 51...
To navigate to the selected menu item, press the ENTER pushbutton. A grayed out menu item is not accessible. The item will be skipped when navigating within the menu screen. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 30 of 51...
GATEWAY IP – The Gateway IP address can be user configured from 0.0.0.0 to 255.255.255.255. The factory default setting is 0.0.0.0. This field is to support future features and currently is not used. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 31 of 51...
NOTE: The monitor will provide an audible confirmation of restoration of a previous configuration by sounding the buzzer (five chirps). 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 32 of 51...
Page 42
Minimum Flash time used and that the jumpered value cannot be less than five seconds. If the jumpered value is less than five seconds, it will be displayed as five seconds as this will be the value used. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 33 of 51...
Page 43
CO-CHAN INCLUDES YEL – When this feature is enabled the monitor will include the yellow of the child channels as well as the green (and the Walk if in Type 12 mode). The factory default for this feature is NO. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 34 of 51...
Page 44
EASY FYA PROGRAMMING –– If NO is selected then permissive jumpers are required between the FYA channel and the associated protected channel. If YES is selected then the permissive jumpers are required between 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 35 of 51...
Page 45
See Section 2.6.9 for more information. ECONOLITE FRAMES – When this feature is enabled the monitor will respond to special SDLC frames requested by Econolite controllers. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 36 of 51...
Page 46
Bit 81 of the Type 129 Response Frame will be set to 1 to indicate a flash rate failure. If YES is selected and a FYA is on for more than 700 milliseconds the FYA will be treated as a solid yellow arrow indication. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 37 of 51...
Page 47
MMU2 channels available. The Red and Yellow or the Green of the Protected Left Turn has to be rewired. 11RY 15RY 2 5G 2 5G 13RY 2 11G 2 15G 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 38 of 51...
Page 48
Peds in the FYA Configuration Type G and H. This leaves 4 MMU2 channels available. There is also less cabinet rewiring, because the protected phase remains in 1, 3, 5, 7. 3RYG 7RYG 3RYG 7RYG 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 39 of 51...
Page 49
13,14,15,16 as FYAs. The MMU2 all 16 channels to monitor the 8 phases and 4 Peds. There is less cabinet rewiring, because the protected phase remains in 1, 3, 5, 7. 3RYG 7RYG 3RYG 7RYG 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 40 of 51...
Page 50
Press HELP at each warning to receive additional information on each warning. The wizard will not tell you which permissive jumpers to install 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 41 of 51...
Clear individual logs. CLEAR ALL LOGS Clear all logs. LOGGING THRESHOLDS View and/or edit the AC Logging Threshold settings of high voltage alarm, low voltage alarm, and power interrupt duration. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 42 of 51...
Use the up (▲) or down (▼) pushbutton to scroll through the list of features that are different. Press the ENTER pushbutton or the ESCAPE pushbutton to exit. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 43 of 51...
NOTE: When the Clear All Logs function is used, the monitor will provide an audible confirmation by sounding the buzzer (five chirps). 4.6.3.4 AC LOGGING EVENTS THRESHOLDS See Section 4.6.2.2.1 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 44 of 51...
NOT AVAILABLE IN TYPE 12 will be displayed. Press the ENTER pushbutton or the ESCAPE pushbutton to exit. NOTE: A more condensed version of this information is available by pressing ESCAPE at the Run Time display. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 45 of 51...
(BOOT1), secondary bootloader (BOOT2), main monitor code (MAIN), AC signal processor (DSP), and DC signal processor (DC). This display is view only. Press the ESCAPE pushbutton to exit. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 46 of 51...
The indicator for a field input will be on if the RMS voltage over the last 33 milliseconds (two cycles of AC power) is above the threshold for that type of input. (See Section 3.2 for the voltage levels for each type of input.) 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 47 of 51...
Any monitoring function that is disabled for any reason will display a Function Disabled indication. 4.7.5 FUNCTION DISABLED INDICATION When a function has been disabled, the associated indicator will turn on for 50 milliseconds once every two seconds. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 48 of 51...
RESET pushbutton or Save Changes is confirmed in fault monitoring configuration on the front panel, the pending changes will be lost and the original settings will be used on power up. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 49 of 51...
This ensures that the user cannot inadvertently upgrade a monitor with the incorrect firmware and that the firmware file has not been tampered with. 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 50 of 51...
Page 60
ID Info Ethernet Settings Status DC Inputs Ethernet Port Stats DC Processor Com Stats Log View Config Pending Diag Stats SDLC Speed Stats Logging Thresholds Config Fault Location PC Factory 889-3819-00 MMU2-1600GE series Operations Manual Rev Apr 2020 Page 51 of 51...