POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2
24V WIRING.
Fig. 9. Typical wiring diagram for humidifier using H1008 Automatic Humidity Control.
For PC8900/W8900 Wiring Connections:
Connect only the two yellow wires to the W8900 (red wire
connections are not used). See the typical wiring diagram in
Fig. 10.

Plumbing Saddle Valve

Hot or cold water, either hard or softened, can be used in the
humidifier.
1. Use the self-piercing saddle valve included to tap into
the water supply line at an appropriate location.
CAUTION
Equipment Hazard.
Improper installation can cause equipment
damage.
Do not use any line connected to an air conditioner.
MECHANICAL
HUMIDISTAT
2
SAIL
SWITCH
1
POWER SUPPLY. PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION
AS REQUIRED.
2
24V WIRING.
Fig. 8. Typical wiring diagram of sail switch with humidifier.
DEHUM
DEHUM
HUM
HUM
HOT
COM
24VAC
BLACK
AUTOMATIC HUMIDITY CONTROL
BLACK
1
SOLENOID
3
HEAT ONLY APPLICATIOIN SHOWN. SIMILAR WIRING
REQUIRED IN HEAT AND COOL SYSTEM WITH ONE
OR TWO TRANSFORMERS.
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER
120 VAC
1
HUMIDIFIER
YELLOW WIRES
M12685
OUT
OUT
G
CG
CW
W
FROST FACTOR
SETPOINT DIAL
PC8900
1
2
3
4
HE365
HUMIDIFIER
120
3
VAC
2
1
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
OPTIMAL CONTROL ACHIEVED WHEN USING OUTDOOR AIR SENSOR.
RED WIRES ARE NOT USED IN THIS APPLICATION.
3
Fig. 10. Typical wiring diagram for humidifier using
PC8900/W8900.
5
ROOM THERMOSTAT
G
W
R
3
FAN
RELAY
FURNACE
TRANSFORMER
HEAT
RELAY
L1
(HOT)
L2
1
M12820B
W8900B
2
OPTIONAL
OUTDOOR
AIR SENSOR
M14816
68-0243