Advertisement

Quick Links

Trademarks
®
Autel
, MaxiSys
®
MaxiCheck
are trademarks of Autel Intelligent Technology Corp., Ltd.,
registered in China, the United States and other countries. All other marks
are trademarks or registered trademarks of their respective holders.
Copyright Information
No part of this manual may be reproduced, stored in a retrieval system or
transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise without the prior written permission of
Autel.
Disclaimer of Warranties and Limitation of Liabilities
All information, specifications and illustrations in this manual are based on
the latest information available at the time of printing.
Autel reserves the right to make changes at any time without notice. While
information of this manual has been carefully checked for accuracy, no
guarantee is given for the completeness and correctness of the contents,
including but not limited to the product specifications, functions, and
illustrations.
Autel will not be liable for any direct, special, incidental, indirect damages or
any economic consequential damages (including the loss of profits).
IMPORTANT
Before operating or maintaining this unit, read this manual carefully, paying
extra attention to the safety warnings and precautions.
For Services and Support
pro.autel.com
www.autel.com
1-855-288-3587/1-855-AUTELUS (North America)
0086-755-86147779 (China)
Support@autel.com
For technical assistance in all other markets, contact your local selling agent.
®
®
, MaxiDAS
, MaxiScan
®
®
, MaxiTPMS
i
®
, MaxiRecorder
, and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MaxiIRT IR100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Autel MaxiIRT IR100

  • Page 1 All information, specifications and illustrations in this manual are based on the latest information available at the time of printing. Autel reserves the right to make changes at any time without notice. While information of this manual has been carefully checked for accuracy, no...
  • Page 2: Considerations

     Do NOT use the product if its enclosure is damaged. Contact our local distributors or agents of Autel under such condition.  Stop using the product immediately if it is found with smoke, spark,...
  • Page 3 In case of such condition, the product power supply should be powered off at once. After the smoke and peculiar smell disappears, contact our local distributors or agents.  Do NOT remodel the adapter or the power cable. Otherwise, such remodeling may cause short circuit or fire. ...
  • Page 4  Do NOT dip the product into water or avoid being caught by water. If the enclosure is caught by water or other liquid, dry it immediately. If water or other liquid enters the inside of the instrument, power off the product at once.
  • Page 5  Long-time storage and regular charging. The product should be placed at a cool and dry environ ment if it not been used for a long time. If the product installed with battery is stored for a long time, charging should be made regularly. Otherwise, the battery will run out and its service life will be shortened.
  • Page 6: Table Of Contents

    CONTENTS ....................AFETY NFORMATION ....................... ONSIDER ATIONS ........................ARNING USING THIS MANUAL ..................1 ......................1 ONVENTIONS GENERAL INTRODUCTION ................2 ........................2 VERVIEW ........................3 LEANING ....................3 AIN TE NANC E ............. 4 HARGING THE ATTERY AND ESCRIPTION PRODUCT DESCRIPTION ................
  • Page 7: Using This Manual

    Using this Manual This manual contains device usage instructions. Some illustrations shown in this manual may contain modules and optional equipment that are not included in your system. Conventions The following conventions are used. Bold Text Bold text is used to highlight selectable items such as buttons and menu options.
  • Page 8: General Introduction

    General Introduction For a long time, infrared thermal imaging detection technology has become an important means to ensure industrial safety in developed countries. It is widely used in many fields including electric power, metallurgy, petro - chemistry, machinery, coal, traffic, fire control and national defense, etc. It can perform real-time detection at high voltage, high current and high speed to find potential problems and prevent malfunction.
  • Page 9: Cleaning

    Compact yet rugged, the product is easy to operate and has strong function. It is the ideal selection for electric power, electronic manufacturing, industrial inspection and other fields. The measurement accuracy and usability of the infrared thermal camera are improved with the functions below. ...
  • Page 10: Charging The Battery And Description

    Wipe the lens surface by making circular motion and discard the cloth. Repeat the above steps with new cloth dipped with cleaner if necessary. Charging the Battery and Description Use USB cable to charge:  The product has built-in chargeable 26650 lithium batteries. ...
  • Page 11: Product Description

    Product Description Function Description Figure 3-1 Function Description – Front Display Screen Menu Key/On/Off Key Navigation Key: Left...
  • Page 12 Navigation Key: Up Selection Key/Enter Key Navigation Key: Right Navigation Key: Down Handheld Figure 3-2 Function Description - Back Micro USB (open the cap for use) 10. Visible Light Camera...
  • Page 13: Display Description

    11. Infrared Imaging Sensor 12. Image Capture Key 13. Battery Display Description Figure 3-3 Screen Display  Color code: used to mark the color corresponding to the relative temperature from low to high in the field of version.  The central point temperature cursor: used to indicate the central position in the screen area.
  • Page 14: Technical Specifications

    Technical Specifications Table 3-1 Specifications Item Description Display screen 3.5-inch full-view TFT display Infrared image resolution 320×240 Visible image resolution 300,000 pixel LCD resolution 640×480 Field angle 56° ×42° Thermal sensitivity 0.07° C Frame rate of thermal images Focus mode Fixed Wavelength coverage 8-14um...
  • Page 15 Item Description Product size 256mm×97.2mm×128.9mm Product weight 588g Working temperature 0° C to 45° C Storage temperature -20° C to 60° C Relative humidity 85%RH...
  • Page 16: Getting Started

    Getting Started Initial Operation Power On and Off Press and hold the " / MENU" key for more than 3 seconds to turn the infrared thermal camera on or off. LCD Screen Display After turning on the product, the screen shows the thermal imaging status. NOTE Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures .
  • Page 17 Hiding Highest/Lowest Temperature Column at the Screen Bottom Under the operation after normal start up, press the " " key and the screen bottom will display highest/lowest temperature column. Press the " " key to hide it. Image Export The saved images can be viewed on or exported to a computer after the product is connected to the computer by a Micro USB cable.
  • Page 18: Menu Operation

    Menu Operation Press the " /MENU" key and the menu bar appears. Options "Image overlapping", "Image", "Color palette", "Emissivity" and "Setting" are available at the menu. Image Overlapping Image Overlapping Description Image overlapping enables the product to capture the visual image of every infrared image and align them to accurately display temperature distribution in the target area.
  • Page 19: Image

    press the " ", " ", " ", or " " key to switch, select "Yes", then press the "SELECT/ENTER" key. The image overlapping parameters can be reset, as shown in Figure 5-1. Figure 5-1 Resetting Image Overlapping Image View Image Press the "...
  • Page 20: Color Palette

    Press the " " key to enter image list. Press the " " or " " key to select the image, then press the "SELECT/ENTER" key to view image. Press the " " or " " key to view the precious or the next image. Press the "SELECT/ENTER"...
  • Page 21 Figure 5-3 Color Palettes Application of Color Palette Figure 5-4 Setting Color Palettes Press the " /MENU" key to enter the main menu and select " " (color palette) option and press the " " key to enter the color palette list. Press the "...
  • Page 22: Emissivity

    Emissivity Emissivity Description The emissivity of the infrared thermal camera can be adjusted from 0.01 to 1.00 with the default value of 0.95. Many common objects and materials (such as timber, water, skin and textile fabric) can reflect the heat energy effectively, so it is easy to obtain relatively correct measurement value.
  • Page 23 Figure 5-5 Setting Emissivity Press the " /MENU" key to enter the main menu. Then select the " " (emissivity) option and press the " " key to enter the emissivity list. Press the " " or " " key to select the emissivity. Then press the "SELECT/ENTER"...
  • Page 24: Settings

    Settings Press the " /MENU" key and select the " " (setting) option in the main menu. Press the " " key to enter the "Settings" submenu.
  • Page 25 Figure 5-6 Settings Auto Shutdown Setting After entering the "Settings" submenu, select " Auto shutdown", you can press the " " key in the navigation key to enter the auto shutdown setting. Three modes are available, no auto shutdown, auto shutdown in 5 minutes, and auto shutdown in 20 minutes.
  • Page 26 Language Setting After selecting " " (language), press the " " key to enter the language option. Four languages are available: English, Chinese, Italian, and German. Unit Setting After selecting " " (unit), press the " " key to enter the temperature unit option.
  • Page 27 Figure 5-7 Setting Time  Press the " " or " " key to select year, Month, Day, Hour, Minute, or Second.  Press the "SELECT/ENTER" key to enter the editing state.  Press the " " or " " key to select the figure to be changed. Press the "...
  • Page 28 Figure 5-8 Cursor Setting  Press the " " or " " key to select "Off" or "On" to disable or enable the cursor. Then press the "SELECT/ENTER" key to determine the selection.  After the setting is completed, press the " "...
  • Page 29 Figure 5-9 Wi-Fi Setting  Press the " " or " " key to select "Off" or "On". Then press the "SELECT/ENTER" key to determine the selection.  After the setting is completed, press the " " key to return. Press the " /MENU"...
  • Page 30 NOTE If the mobile device is not successfully connected to the product, refresh the webpage on the mobile device. Click the camera icon on the mobile device and the image is saved on the product as shown in Figure 5-10. Figure 5-10 Saving Images Through a Mobile Device Click "Images"...
  • Page 31: Troubleshooting

    Troubleshooting If you encounter any problem when using the infrared thermal camera, refer to Table 6-1 to fix the problem . If the problems are not solved, cut off the power supply and contact the manufacturer. Table 6-1 Troubleshooting Failure phenomenon Cause Solution The battery is not...
  • Page 32: Warranty

    Warranty Limited One Year Warranty Autel Intelligent Technology Corp., Ltd. (the Company) warrants to the original retail purchaser of this device, that should this product or any part thereof during normal consumer usage and conditions, be proven defective in material or workmanship that results in product failure within one (1) year period from the date of purchase, such defect(s) will be repaired, or replaced (with new or rebuilt parts) with Proof of Purchase, at the Compan y’s option,...

Table of Contents