Saia-Burgess Controls Ltd. Content Content Document-History ................... 0-3 Trademarks ..................... 0-3 Quickstart Introduction ..................... 1-1 Use of the PCD7.D230, D231 and D232 terminals as remote displays for ..PCS1 ....................... 1-2 1.2.1 Configuration with one terminal as remote display ........1-2 1.2.2 Configuration with one terminal as second display for PCS1 .......
Page 3
Use of the function “Play as” of PCD7.D230 with the HMI-Editor ....5-5 Creation of user dialogue with the HMI-Editor ..........5-6 Maintenance Care ........................ 6-1 Appendix Icons ....................... 7-1 Code maps ...................... 7-2 Address of the Saia-Burgess company ............7-4 Manual PCD7.D23x│Document 26/795; Edition E7│15.04.2005...
Saia-Burgess Controls Ltd. Quickstart Introduction Quickstart Introduction This manual covers the technical aspects of the PCD7.D23x graphic terminals. The aim of the Quickstart chapter is to talk about the essentials regarding the use and installation aspects of PCD7.D23x components. We are talking about: ●...
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for PCS1 Use of the PCD7.D230, D231 and D232 terminals as remote displays for PCS1 1.2.1 Configuration with one terminal as remote display Valid for: PCS1.C822, C823, C882, C883 (without integrated display) A - Basic equipment with RS 232 interface ����...
Page 7
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for PCS1 B - Extra PCD7.F110 interface for RS 422 ���� ��� ���� �� ����� ● RS 422: use the port 1 of the terminal block X4 PCD7.D23x setup (recommended): (see also chapter 3)
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for PCS1 1.2.2 Configuration with one terminal as second display for PCS1 Valid for: PCS1.C820, C821, C880, C881 (with integrated display) A - Extra PCD7.F120 interface for RS 232 D230 only The integrated display is connected physically on the port 2.
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for PCS1 1.2.3 Configuration with two or more PCD7.D230, D231 and D232 terminals as remote displays for PCS1 (mixing not possible) Valid for: PCS1.C822, C823, C882, C883 (without integrated display) A - Basic equipment with RS 232 interface + Extra PCD7.F120 interface for RS Configuration with 2 PCD7.D230 terminals (or 2 D231 or 2 D232)
Page 10
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for PCS1 B - Extra PCD7.F110 interface for RS 485 Configuration with 3 PCD7.D230 or 3 D231 or 3 D232 ● Use the port 1 of the terminal block X4 PCD7.D23x setup (recommended):...
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for the whole PCD range Use of the PCD7.D230, D231 or D232 as remote displays for the PCD range 1.3.1 Configuration for one terminal A - with RS 232 ���� �� ���� �� ����...
Page 12
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for the whole PCD range B - with RS 422 ���� �� ���� �� ���� ● Use one port RS 422 PCD7.D23x setup (recommended): (see also chapter 3) Baudrate: 9600 or 19200 bps...
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for the whole PCD range 1.3.2 Configuration for several terminals (mixing is not possible) A - with several RS 232 ports (with or without RTS/CTS) ������������� ���� � ��������� �� � ���� �� � ����...
Page 14
Saia-Burgess Controls Ltd. Quickstart Use of the PCD7.D23x terminals for the whole PCD range B - with one RS 485 port Up to 31 PCD7.D230 or D231 or D232 terminals can be connected to one RS 485 port. PCD7.D23x setup (recommended):...
Saia-Burgess Controls Ltd. Quickstart Special confi guration with several PCD7.D23x terminals Special configuration with several terminals with RS 422 Free Terminal Protocol (Multi Drop) (mixing is not possible) Available for PCS1 without display and all the range of PCD. This mode allows the connection of several terminals on one RS 422 port. In this case, only one terminal is active (sender and receiver) and the other are passive (Read only).
Saia-Burgess Controls Ltd. Quickstart Power supply/Communication connector/Dimensions Power supply Connection type Connector J2 pin no. 24 VDC 24 VDC +30% /-20% 19 VAC ±15% full-wave rectified PGND Power consumption: 200 mA on 24 VDC Power supply via plug-in spring connector for wires of max 1,5 mm...
Saia-Burgess Controls Ltd. Hardware-System Overview Function Hardware-System Overview Function The new range of PCD7.D230, D231 and D232 terminals are remote graphic displays for the Saia PCS1 and the whole Saia PCD range. ® ® They have been developed for building automation and industrial applications. In combination with the HMI-Editor, an add-on tool of the PG5 programming package, they provide a simple way of implementing menu-driven user interface.
Saia-Burgess Controls Ltd. Hardware-System Overview Technical data Customising A polyester foil with the type and the Saia-Burgess logo covers the whole front side. Upon request: ● Special labelling is available on request ● Special design (own logo) can be realized and placed on the front-panel.
Saia-Burgess Controls Ltd. Hardware-System Overview Block diagram Operating temperature 0...50°C Storage temperature -25...+70°C Permissible humidity 5...95% r. H. w/o condensation (DIN 40 040 class F) Protection system (front) IP 54 IP 65 IP 65 2.2.1 Block diagram Communi- cation Display graphic...
Saia-Burgess Controls Ltd. Hardware-System Overview Standard interface connection cables Standard interface connection cables 2.3.1 PCD7.K423: for interface RS 232 (with handshake RTS/CTS) Recommended Connection between terminal PCD7.D23x and CPUs of the series PCD1, PCD2, PCD3, PCS1 or PCD4. Free cable ends (with sleeves) in 2.5 m lengths.
Saia-Burgess Controls Ltd. Hardware-System Overview Standard interface connection cables 2.3.3 PCD7.K413: for interface RS 232 Recommended Connection between terminal PCD7.D23x and PGU socket of all PCDs. Free cable ends (with sleeves) in 2.5 m lengths. Terminal PCD7.D23x “PGU” at PCD1, PCD2, PCD3,...
Saia-Burgess Controls Ltd. Hardware-System Overview Standard interface connection cables 2.3.5 PCD7.K456: for interface RS 485 Connection between terminal PCD7.D23x and CPUs of the series PCD1, PCD2, PCD3, PCS1 or PCD4. Free cable ends (with sleeves) in 5 m lengths. Terminal PCD7.D23x “PGU”...
Saia-Burgess Controls Ltd. Hardware-System Overview User created interface connection cables 2.4.3 Connection in RS 422 Multi Drop (example with PCD7.F110 module) PCD7.D23x PCD7.D23x PCD1/2, PCS1 Address 01 Address 01 Display Control Full Control 9-pole 9-pole Module D-type connector D-type connector PCD7.F110...
Saia-Burgess Controls Ltd. Communication Serial mode Communication mode setting Serial mode – Baudrate and Controls The selected PCD communication mode and PCD7.D23x communication settings in the setup menu must match. The PCD communication mode (MC0/1/2/4/5) is selected in the HMI using the HMI set-up screen: ●...
Saia-Burgess Controls Ltd. Communication Serial mode 3.1.2 Special modes (available with D23x, FW 25) RS 232/RS 422 with XON/XOFF (R) reduced Baudrate Type Handshake Control Graphic support (HMI) 4800 bps with XON/XOFF (R) RS 422 with Free Terminal Protocol (Multi-Drop)
Saia-Burgess Controls Ltd. Software Basic commands Software The terminal interface can be in different operation modes: ● Direct mode: The direct mode is the default full duplex mode with key code directly sent if the buttons on the PCD7.D231 or PCD7.D232 are pushed or the rotary wheel as- sembly on the PCD7.D230 is used.
Page 28
Saia-Burgess Controls Ltd. Software Basic commands Compatibility PCD7. D1x0 D1x0 D202 D232 D231 D230 dec. hex. Meaning stand. Fkeys Autorepeat Autorepeat Long turn off Repeat off finished finished plus + (plus) shift-dot , (comma) shift-plus - (minus) . (point) A, F1 code...
Saia-Burgess Controls Ltd. Software Basic commands Compatibility PCD7. D1x0 D1x0 D202 D232 D231 D230 dec. hex. Meaning stand. Fkeys Enter Key Down arrow / Push dial starts at power-up Enter key at at power-up only power-up only only - no...
Page 30
Saia-Burgess Controls Ltd. Software Basic commands Display Definition Further information Response Direct mode 0xb5 Run time error Supervisory signal: Optional indication for special indication: test cases HW Error (No normal operating case) 0xb6 Start up error indi- Supervisory signal: Display missing or defect at cation: startup.
Page 31
Saia-Burgess Controls Ltd. Software All commands All commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x add bar size percen- fill data tage scroll bar size percen- fill data tage show bar (fix)
Page 32
Saia-Burgess Controls Ltd. Software All commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x show symbol symbol symbol line cursor home Default Default Default echo off fault Default Default Default auto lf on...
Page 33
Saia-Burgess Controls Ltd. Software All commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x contrast medium default default default contrast medium +1 contrast medium +2 contrast medium +3 contrast medium +4 contrast medium +5...
Page 34
Saia-Burgess Controls Ltd. Software All commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x set codemap 437 default autorepeat off autorepeat on default default with current setting autorepeat on/off indi- cation only on cursor...
Page 35
Saia-Burgess Controls Ltd. Software All commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x Symbol line 2 mode on 27 FTP move cursor <EOT> absolute Auto repeat off FTP Switch cursor <EOT>...
Page 37
Saia-Burgess Controls Ltd. Software Advanced commands Advanced Commands The terminals switch in the serial data/setup mode with the data/setup mode command (ESC S). In this mode handshake is used with code 0x16 0x30 (DLE-0) as OK indication. Key detection is not active.
Page 39
Saia-Burgess Controls Ltd. Software Advanced commands PCD7. Parameters Compatibility D232 D231 D230 Commands dec. hex. 1 cds. D100 D1x0 D202 D250 D79x cursor permanent key filter off key filter on default default set screen replay full ) 27 set screen replay...
Page 40
Saia-Burgess Controls Ltd. Software Advanced commands This mini browser function is also used in the setup menu and can be verified there for its working. ) The upper page character code can direct to the default or alternative code page or a combined use of them using redirection tables. The selection of the direct of redirect access goes over the serial commands for code map selection.
Saia-Burgess Controls Ltd. Software Free Terminal Protocol Mode Free Terminal Protocol Mode To be able to use the RS485 as half duplex interface, the PCD7.D23x have to be used in a “Free Terminal Protocol” Mode (PCD7.D79x compatible). In this serial command mode: by default no responses will be sent.
Page 42
Saia-Burgess Controls Ltd. Software Free Terminal Protocol Mode mand. In inactive state also all key entries are lost. In active state the terminal will react on all commands. Key entries are queued and can be requested using the Free Terminal Protocol poll command.
Page 43
Saia-Burgess Controls Ltd. Software Free Terminal Protocol Mode Free Terminal Protocol Mode compatibilty aspect The Free Terminal Protocol Mode is compatible with the command set of the SBC PCD7.D79x series, the so called protocol free terminals series, with some exceptions: ●...
Page 44
Saia-Burgess Controls Ltd. Software Free Terminal Protocol Mode vanced commands only. For advanced command programming and use other than with the HMI contact SBC for the programming details. With the 20 ms default setting the timing is: Before start of transmission: ●...
Saia-Burgess Controls Ltd. Software Return codes in FTP mode Return codes in FTP mode PCD7. D232 D231 D230 dec. hex. FTP Code Meaning up arrow up arrow right arrow right arrow Turn right right down arrow down arrow down left arrow...
Page 46
Saia-Burgess Controls Ltd. Software Return codes in FTP mode PCD7. D232 D231 D230 dec. hex. FTP Code Meaning shift shift shift func- tion - no code sent Enter Key Down / Enter Push Key starts at power-up at power-up setup...
Saia-Burgess Controls Ltd. Software Compatibility Compatibility between PCD7.D202, D160/170 commands and PCD7.D232, D231 commands 4.6.1 PCD7.D202, D160/170 (and D250) commands no longer used with the PCD7.D232/D231 terminals These commands are mainly test commands as “display test“, “hardware test”, “dem- onstration display”, “LED test”… which are not basic commands.
Saia-Burgess Controls Ltd. Handling Setup menu Handling Setup Menu How to enter into the “Setup menu”? ● D230: Press the single knob at the display of the version indication to power-up ● D231 and D232: Press any key (excepted Shift key) at the display of the ver- sion indication to power-up ●...
Page 49
Saia-Burgess Controls Ltd. Handling Setup menu “Status Info” allows to show the hardware and firmware version* and check RAM and EEPROM. *If a problem occures and in order to help you better , the “Technical Customer Service” needs to know the hardware- and firmware-version of the terminal as well as other information on the label sticks on the backside of the housing.
Page 50
Saia-Burgess Controls Ltd. Handling Setup menu Set the baudrate according to the communications mode (see also chapter 4) to match baudrate of the PCD or PCS. (The baudrate is also set in the HMI-Editor.) PCD7.D230: Select the line by turning the single knob to the left or right. Press the single knob to select the baudrate and press the single knob once again to save the baudrate.
Page 51
Saia-Burgess Controls Ltd. Handling Setup menu Back to default PCD7.D230: By pressing the sinle knob, all parameters are restored. PCD7.D231 and D232: By pressing the “Enter” key, all parameters are restored. (Default parameters: set contrast: middle / set baudrate: 9600 / serial mode RS 232 RTS/CTS) “Enabled or disabled setup access”...
Saia-Burgess Controls Ltd. Handling Use of the function “Play as” Use of the function “Play as” of PCD7.D230 with the HMI-Editor The single-knob control is not active with the “Play as” function, it is replaced by keys. To turn up (clockwise), click on the upward arrow button To turn down (anticlockwise), click on the downward arrow button To simulate a short push (enter).
Saia-Burgess Controls Ltd. Handling Creation of user dialogue with the HMI-Editor Creation of user dialogue with the HMI-Editor The HMI-Editor The HMI-Editor has a tree structure, similar to that of Windows-Explorer. The root- menu (standby and login) is the first menu window displayed on the terminal, and may contain text, the date, time of day and PCD variables.
Page 54
Saia-Burgess Controls Ltd. Handling Creation of user dialogue with the HMI-Editor New functionalities with HMI-Editor V1.2 1 System texts A list of system texts has been implemented. The list is in the Object Attribute tab. The HMI compiler will cut or extend the text to the correct length.
Saia-Burgess Controls Ltd. Maintenance Care Maintenance Care These display terminals have been designed for maintenance-free continuous operation. Clean the front of the display terminal if necessary. Use a damp, lint-free cloth for cleaning. Do not use a dry cloth, cleaning agents or chemical substances.
This sign accompanies instructions that must always be followed. Explanations beside this sign are valid only for the SAIA-Burgess PCD Classic serie. Explanations beside this sign are valid only for the SAIA-Burgess PCD xx7 serie. Manual PCD7.D23x│Document 26/795; Edition E7│15.04.2005...
Saia-Burgess Controls Ltd. Appendix Code maps Code maps The terminal support a basic ANSII code map (code 0x20 to 0x7e) and a default and alternative code map for upper page code 0x80 to 0xff. ANSII code map Position 0 / 8...
Page 58
Saia-Burgess Controls Ltd. Appendix Code maps This character set contains the characters available in the code maps Windows 1250 and Windows 1252 (Mapping is different). Pixel map inversion: At negative entry setting (ESC@N1) at all 6 x8 pixel are inverted before entry.