Electrical Adjustment Instructions - Symphonic FUNAI SYLVANIA Emerson SC309C Service Manual

Hide thumbs Also See for FUNAI SYLVANIA Emerson SC309C:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Win-
dow, Red Color, Dot Pattern, Gray Scale, Mono-
scope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (FL8A, FL8N), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
How to make service remote control
unit:
1. Prepare normal remote control unit. (Part No.
N0107UD) Remove 3 screws from the back lid.
(Fig. 1-1)
2. Added J1 (Jumper Wire) to the remote control
CBA. (Fig. 1-2)
SCREW
Remote control unit (Bottom)
Remote control CBA
How to Set up the Service mode:
Service Mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press " WAKE-UP/SLEEP " button on the service
remote control unit.
1a. DC 117V (+B) Adjustment
(AC Power)
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.
Test point
TP601
(+B)
TP602
(GND)
Tape
---
Note: TP601(+B), TP602(GND), VR601 --- Main CBA
1. Connect the unit to AC Power Outlet.
2. Connect DC Volt Meter to TP601(+B) and
TP602(GND).
3. Adjust VR601 so that the voltage of TP601(+B)
becomes +117±0.5V DC.
Fig. 1-1
Fig. 1-2
1-7-1
Adj. Point
Mode
VR601
M. EQ.
DC Voltmeter
+117±0.5V DC
Plastic Tip Driver
Input
---
-----
Spec.
T4300EA