Manual of the hytherograph
1
Continuous development of our products causes sometimes need to make changes that are not described in this
manual
LAB-EL Elektronika Laboratoryjna Sp.J.
Herbaciana 9, 05-816 Reguły
tel: (022) 7536130, fax: (022) 7536135
email:
info@label.pl
internet site:
LB–570P
1
Version
1.2 April 2015
from the firmware version 2r4
LOGGER program from version 2.1.12
http://www.label.pl/

Advertisement

Table of Contents
loading

Summary of Contents for LAB-EL LB–570P

  • Page 1 LAB-EL Elektronika Laboratoryjna Sp.J. Herbaciana 9, 05-816 Reguły tel: (022) 7536130, fax: (022) 7536135 email: info@label.pl internet site: http://www.label.pl/ Manual of the hytherograph LB–570P Version 1.2 April 2015 from the firmware version 2r4 LOGGER program from version 2.1.12 Continuous development of our products causes sometimes need to make changes that are not described in this...
  • Page 2: Table Of Contents

    2.8.3 Signalization of the registration ..............24 Setting the time of automatic switching off ..........25 2.10 Displaying an additional information............26 2.10.1 Signaling of the errors ................26 COOPERATION WITH THE COMPUTER - DESCRIPTION OF LOGGER PROGRAM ...................... 27 LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 3 Presentation of measurements in the form of a report......37 3.3.3.4 Entering the measurements to file ............39 3.3.3.5 An overview of the file with the registered data ......... 39 TECHNICAL SPECIFICATIONS.............. 40 Measurement specifications ................ 40 Technical parameters.................. 41 External dimensions ..................42 LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 4: Description Of The Hytherograph

    • temperature of the dew point (T • temperature difference T1 - T2, • temperature difference T1 - T • 2 temperature maximum (max T2), • 2 temperature minimum (min T2), • time (hours, minutes). LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 5 (dust protection) Table 1 Sensors covers - pollution filters Meter LB-570P is characterized by a modern construction based on efficient and energy saving microprocessor controller. On the basis of the knowledge of LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 6: Operating Of The Hytherograph

    • A - cover of the sensors, • B - multifunction socket for connecting : interface USB (LB-376A), battery chargers. • C – keyboard, D - LCD screen, • • E - probe socket LB-571. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 7 User's manual for hytherograph LB-570P LB-579 - Stand for the Contact probe LB-571- LB-568A holder on the hytherograph wall LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 8 • probe LB-571 - on request, USB interface LB-376A - on request, • LOGGER program – on request, • LB-579 - stand for the hytherograph – on request, • handle LB-568A - on request, • LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 9: Description Of The Display

    • menu - Means that the menu mode is turned on, alarm • o continuous display indicates that the alarm function is active, o fast blinking means exceeding any of the alarm thresholds. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 10: Description Of The Keyboard

    2 seconds the button is used to to reset the value maxT2, minT2; above the key is located description of this feature - reset (2sec) , • menu - enter the menu mode, LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 11: Hytheograph Switching On And Off

    5 minutes from last pressing of any button on the keyboard. The autmatic switching off time can be set in the range 0 ... 30 minutes. Zero-setting for the automatic switching off time means that this function is LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 12: Sleep Mode

    • Put the hytherograph on a stable basis (for example on a table), press the F and the menu buttons and hold them. • Plug the charger into the socket B marked on Figure 1 - message would display on the screen: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 13: Charging The Battery

    The following states are possible for this indicator: • Charger plugged in: o slow blinking – the batteries are charged, o continuous display - battery charging completed. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 14: Battery Saving

    (sensor) has reached, in addition to the humidity, the temperature of the air to be measured as well. It should be noted that in existing in a particular room the absolute amount of moisture in the air (expressed for example by dew point LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 15 47%. Dependencies between different parameters, which are describing the climate, can be traced back by using the "HUMIDITY CALCULATOR LAB-EL" (KALKULATOR WILGOTNOŚCI LAB-EL) program. The thermal inertia, which occurs between the structure of the sensor housing and air probe in the probe head, is preventing against the alignment of the humidity sensor temperature with the ambient temperature.
  • Page 16: Air Temperature Measurement

    ), maxT2, minT2 and time On lower screen it shows: • the current humidity (H), • current temperature T2 (probe LB-571) - the probe should be connected to the port labeled E in Figure 1, LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 17: Resetting The Values Of Maxt2, Mint2

    2.4.4 Stop the measurement results The results of the measurements can be stopped at any time by pressing stop button. Stop the measurement result is signaled on both lines of the display message: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 18: Setting The Temperature Measurement Resolution

    • OK - enter the selected menu item or approval of an adjustable parameter in menu, • ESC - exit from the menu (or go up one level in the menu). Approval of changes to the parameter in menu is indicated by double beep. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 19: Menu Tree

    An alarm occurrence is signaled in the following manner: with the alarm message , • indicator flashes • on the upper display the temperature is shown, alternating with the message: when the lower alarm of the temperature T1 is exceeded, LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 20: Setting The Alarms

    - on display the following message will be shown: menu alarm ∆ ∆ ∆ ∆ T T2-T maxT2 minT2 CZAS • Confirm with OK button your entry to alarms setting - on the display the following message will be shown: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 21 • Press OK - the message 1.2 starts flashing and the lower display shows the value of the lower temperature alarm threshold T1 - with buttons ↓ ↑ you can set the required threshold (holding the ↓ ↑ button enables the acceleration of threshold setting) LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 22: Registration Of Measurements

    • Enter the menu mode - press menu button . • Settings of alarms are grouped in the menu number 2. - select with the ↓ ↑ buttons this number - on display the following message will be shown: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 23 2.4 – nAdP – switching on / off of the overwriting measurements o 2.5 – bEEP – switching on / off of the sound signal for measurements recording • After selecting for example the option 2.2 on the display there will be shown LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 24: Signalization Of The Registration

    If the registration is enabled, when you turn off the meter, it does not turn off completely - the meter goes into sleep mode. For more information about this mode, refer to Sleep Mode chapter. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 25: Setting The Time Of Automatic Switching Off

    , • Confirm the entered value of the automatic switching off time by clicking OK button - message 3.1 stops blinking, • Press ESC twice to exit the menu mode. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 26: Displaying An Additional Information

    F button time in display mode). Measurements memory error is displayed in the measuring loop only when the registration is active. Errors are displayed in the following manner: menu alarm ∆ ∆ ∆ ∆ T T2-T maxT2 minT2 CZAS The meaning of the errors is as follows: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 27: Cooperation With The Computer - Description Of Logger Program

    KEYS directory. If you purchase a new device just manually copy the attached file with the key for that directory. • Connect LB-570P to computer using converter LB-376A (see chapter description of the USB converter LB-376A), the red led in the converter should light up. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 28 User's manual for hytherograph LB-570P • Run the LOGGER program , from the menu Konfiguracja (Configuration) select Konfiguracja urządzeń (configuration of devices) • the following window will appear: • choose the button dodaj (add) -the window will appear below: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 29 User's manual for hytherograph LB-570P • Select the device LAB-EL LB-570 type and select Port szeregowy (Serial Port ) for Windows 98 and select USB option for Windows XP system (Windows 2000, Windows 7); press OK in the device configuration window, you should...
  • Page 30: Description Of The Usb Lb-376A Converter

    Device menu. 3.2 Description of the USB LB-376A converter The appearance of a LB-376A converter is presented on the Figure 3. Figure 3 Converter USB LB-376A LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 31: Charging The Battery Using The Converter Lb-376A

    (before that you may try to restart your computer). The driver is located in the directory USB of the LOGGER program (for example C:\Program Files\LAB-EL LOGGER\USB). To do this, use the Windows Device Manager to find improperly installed the USB device and update the driver by indicating the USB directory of the LOGGER program, as the location from which you wish to download a new driver.
  • Page 32: Authorization Keys

    LOGGER program (on request) . The key is related to the type of device and its serial number. The keys are stored in the directory: KEYS of the LOGGER program (for example C:\Program Files\LAB-EL LOGGER\KEYS). If the user does not have an authorization key for his/her...
  • Page 33: Changes In The Hytherograph Settings

    • Rozdzielczość temperatury (resolution of the temperature) - setting the temperature resolution 0.1° C or 0.01 °C, • Ustawienia wyłączania (Setting of the switching off) - setting the time of automatic switching off • Resetting the value of the min-max-med. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 34: Reading Of The Measurements

    Pamięć Rejestracji (Zbiór Danych) (Memory Register (data set)) will appear. 3.3.3.1 Presentation of the measurements on the chart In the memory registration window, select button , the chart configuration window will appear: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 35 By double clicking the mouse, you should select these variables that will be drawn on the chart and then select PokaŜ (Show). When you select the "LB-570 T1", "T2"-570 LB and "LB-570RH" window will appear with a chart, for example: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 36: Presentation Of Measurements In The Form Of A Histogram

    Choose in the registration memory window for example the temperature of the "LB-570 T1" and then press the button . The histogram setting window will appear: Select the appropriate settings and then press the OK button. The window with the histogram will appear, for example: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 37: Presentation Of Measurements In The Form Of A Report

    User's manual for hytherograph LB-570P 3.3.3.3 Presentation of measurements in the form of a report In the memory registration window, select button , the report configuration window will appear: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 38 By double clicking of the mouse, you should select these variables that will be drawn on the chart and then select PokaŜ (Show). For example, if you select all of the data series the window with report will appear for example: LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 39: Entering The Measurements To File

    • Point to the file on the disk with saved measurements. • A window will open with the registration memory that was saved in the file. • Data can be review as it has been described in the previous chapters. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 40: Technical Specifications

    10...40 % (for temperatures up to +85 °C) Measurement uncertainty (10 %...90 %) ± 2.0% ± 1 digit at last Measurement uncertainty (beyond the ± 4.0 % ± 1 digit at last range 10 %...90 %) Resolution of measurement 0.1 % LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 41: Technical Parameters

    *) - Going beyond the recommended continuous operating conditions (for example, when installing the device in an open area) requires the application of additional safeguards for an electronic part of the device before outdropping water inside the device. LAB-EL Elektronika Laboratoryjna (electronics lab)
  • Page 42: External Dimensions

    **) -When a resolution is set to 0.01 °C, the lowest registration interval is 2 seconds. TIGHTNESS OF THE CASING LB-570P IP30 LB-376A IP30 4.3 External dimensions EXTERNAL DIMENTIONS LB-570P 200 x 46 x 27 mm LB-376A 56 x 31 x 24 mm LB-571-TM diameter 25mm , length 105mm LAB-EL Elektronika Laboratoryjna (electronics lab)

Table of Contents