SSV DISTRIBUTION PUMP
SYSTEM
OPERATION & MAINTENANCE MANUAL
Manufactured With Pride
In The USA
www.ameriwater.com • 800-535-5585
AmeriWater • 3345 Stop 8 Rd. • Dayton, OH 45414
P/N 98-0096
REV A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSV and is the answer not in the manual?

Questions and answers

Summary of Contents for AmeriWater SSV

  • Page 1 SSV DISTRIBUTION PUMP SYSTEM OPERATION & MAINTENANCE MANUAL Manufactured With Pride In The USA www.ameriwater.com • 800-535-5585 AmeriWater • 3345 Stop 8 Rd. • Dayton, OH 45414 P/N 98-0096 REV A...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1.0 INTRODUCTION ..............1 2.0 THEORY OF OPERATION ............. 1 3.0 INSTALLATION ..............2 4.0 START-UP ................2 5.0 DAILY MONITORING ............. 3 6.0 ADJUSTING THE TIMER ............4 7.0 SPARE PARTS LIST .............. 5 8.0 PUMP CURVES ..............6 9.0 SYSTEM DRAWINGS.............
  • Page 3: Introduction

    The distribution pumps are available as a single pump or a dual pump. All distribution pumps are available in 220V single phase, 208V 3 phase, 230V 3 phase and 460V 3 phase. The distribution pumps use an SSV pump and have a capability of running at rated volume up to 75 PSI.
  • Page 4: Installation

    5. Locate the pump control on a wall as close to the pump system as possible. When installing a distribution pump along with an AmeriWater Central Water System, refer to the Plumbing and Instrumentation Diagram (P&ID) for the best location and where connections are made.
  • Page 5: Daily Monitoring

    6 & 7. DAILY MONITORING AmeriWater recommends that the distribution pump assembly be checked at least once per day to ensure that the pump is building pressure. To do this, read the pressure on the first gage after the booster pump while water is flowing.
  • Page 6: Adjusting The Timer

    ADJUSTING THE TIMER With the power off and the system properly locked out, open the control panel. In the middle of the box, you will see the OMRON timer as shown below. To adjust the timer, simply insert a small screwdriver into the screw on the lower right hand face of the timer. Rotating this will toggle between the time interval modes, which are displayed on the face of the timer.
  • Page 7: Spare Parts List

    SPARE PARTS LIST Description Part Number Pump, 2HP, Single Phase, 30 GPM 80-SV01 Pump, 2HP, Three Phase, 30 GPM 80-SV02 Pump, 3HP, Single Phase, 60GPM 80-SV03 Pump, 3HP, Three Phase, 60GPM 80-SV04 Check Valve, Ball Spring Loaded 041-0033 Stainless Steel Pressure Gauge 0-100psi 43530710 Contactor, AB, 9 AMP, 3 Pole, 120V Coil 61670245...
  • Page 8: Pump Curves

    10.0 PUMP CURVES 98-0096A...
  • Page 9 98-0096A...
  • Page 10: System Drawings

    SYSTEM DRAWINGS Single Distribution Single Phase Controller 98-0096A...
  • Page 11 Single Distribution Single Phase Controller Schematic 98-0096A...
  • Page 12 Single Distribution Three Phase Controller 98-0096A...
  • Page 13 Single Distribution Three Phase Controller Schematic 98-0096A...
  • Page 14 Dual Distribution Controller 98-0096A...
  • Page 15 Dual Distribution 220 Volt Single Phase Controller Schematic Dual Distribution 208 Volt Three Phase Controller Schematic 98-0096A...
  • Page 16 98-0096A...
  • Page 17 Dual Distribution 230/460 Volt 3 Phase Controller Schematic 98-0096A...
  • Page 18 Single Distribution Pump Assembly 98-0096A...
  • Page 19 Dual Distribution Pump Assembly 98-0096A...
  • Page 20: Troubleshooting Guide

    10.0 TROUBLESHOOTING GUIDE PROBLEM: DISTRIBUTION PUMP WILL NOT BUILD PRESSURE Is the feed valve Open the feed open? valve. Is the pump Adjust the throttle discharge throttle valve until the valve adjusted pump builds properly? pressure. Open the valve at each station, one valve at a time until water begins to escape.
  • Page 21 (PVC). The AmeriWater system you have purchased may contain PVC or stainless steel parts. While warnings are only required in the State of California, AmeriWater has initiated the use of Prop 65 labeling for all products to ensure compliance with California regulations. Please note that the above warning does not necessarily mean that the product that you have purchased is unsafe.