Please read this user's manual carefully to ensure proper use, installation and maintenance
Ithomis Str. 6, Chalandri, GR-15231, Athens - Greece
Τel: +302106715510 / +302117007269/ +302117007270
Fax: +302106542877
Website:
www.ecofer.com.gr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fairland INVERX VERTICAL and is the answer not in the manual?

Questions and answers

Summary of Contents for ECOFER Fairland INVERX VERTICAL

  • Page 1 INSTALLATION & USER MANUAL INVERX ERTICAL POOL HEAT PUMPS Please read this user’s manual carefully to ensure proper use, installation and maintenance Ithomis Str. 6, Chalandri, GR-15231, Athens - Greece Τel: +302106715510 / +302117007269/ +302117007270 Fax: +302106542877 Website: www.ecofer.com.gr...
  • Page 3: Table Of Contents

    CONTENTS 1. General information: ..........................- 3 - 1.1. Contents: ..............................- 3 - 1.2. Operating conditions and range: ......................- 3 - 1.3. Advantages of different modes: ......................- 3 - 2. Operations ..............................- 6 - 2.1. Notice before using ..........................- 6 - 2.2.
  • Page 4 Installation and user manual Warning: a. Please read the following tips before installation, use and maintenance. b. Installation, removal and maintenance must be carried out by Professional personional in accordance with the instructions. Gas leakage test must be done before and after installation. 1.
  • Page 5 Installation and user manual d. Installation must be stopped if any gas leakage, and the unit must be returned to professional maintenance center. 3. Transportation & Storage a. Sealing is not allowed during transportation b. Transporting goods at a constant speed is needed to avoid sudden acceleration or sudden braking, so as to reduce the collision of goods.
  • Page 6: General Information

    Installation and user manual 1. General information: 1.1. Contents: After unpacking, please check if you have all the following components. NOTICE: Please do not install wrong direction of the water union. 1.2. Operating conditions and range: ITEMS RANGE Operating range Air temp -15℃~43℃...
  • Page 7 Installation and user manual MODE ADVANTAGES Turbo mode Heating capacity: 120% Fast heating Heating capacity:100%~20% Smart mode Intelligent optimization according to ambient temperature and water temperature Energy efficiently saving Silence mode Heating capacity: 60%~20% Use at night Kind reminder: This heat pump has Power-off memory function. When the power is recovered, the heat pump will restart automatically.
  • Page 8 Installation and user manual 5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid fire. 6. If any abnormal circumstances occurred, e.g.: abnormal noises, smells, smokes and leakage of electricity, switch off the main power immediately and contact your local dealer. Don’t try to repair the heat pump by yourselves.
  • Page 9: Operations

    Installation and user manual 9. Please note that following codes are not failure. Codes No water flow Anti-Freezing Reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal 2. Operations 2.1. Notice before using ① For longer service life, please ensure water pump is on before heat pump is on, and water pump is off after heat pump is off.
  • Page 10 Installation and user manual SYMBOL DESIGNATION FUNCTION 1. Power On/Off ON/OFF 2. Wifi setting 1. Press it for 3 seconds to unlock/lock screen Lock/Unlock 2. After screen is unlocked, press it to select mode. Mode Selection Auto (12~40℃) Heating (18~40℃) Cooling (12~30℃) Speed Select Turbo/Smart/Silence mode Up / Down...
  • Page 11 Installation and user manual Heating Heating capacity percentage Wifi connection Water inlet Water outlet 1.Power On: Press for 3 seconds to light up screen, then press to power on heat pump. 2.Adjust Set Temperature: When screen is unlocked, press to display or adjust the set temperature.
  • Page 12: Daily Maintenance And Winterizing

    Installation and user manual b. Compulsory Defrosting: When heat pump is heating, press together for 5 seconds to start compulsory defrosting, and will be flashing. After defrosting, will stop flashing. (Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more than 10 minutes.) 6.Temperature display conversion between ℃...
  • Page 13: Technical Specification

    Installation and user manual 3. Technical specification Model IXCR26V IXCR36V IXCR46V IXCR56V IXCR66V IXCR80V IXCR80VT IXCR110VT Advised pool volume (m 20~40 25~50 30~60 40~75 50~100 65~120 65~120 90~160 ο ο Working air temp (℃) C ~ +43 Performance Condition: Air 28°C, Water 26°C, Humidity 80% Heating capacity (kW) in SMART 12,0 15,4...
  • Page 14: Transportation

    Installation and user manual 4. Transportation 4.1. When storing or moving the heat pump, the heat pump should be at the upright position. 4.2. When moving the heat pump, do not lift the water union since the titanium heat exchanger inside the heat pump will be damaged.
  • Page 15: Installation Instruction

    Installation and user manual 5.2. Installation instruction 5.2.1. Location and size To avoid air recirculation, the heat pump should be installed in a place with good ventilation or should reserve sufficient space for installation and maintenance. Please refer to the schema below: * MINIMUM DISTANCE Filter...
  • Page 16 Installation and user manual UNIT=MM IXR26V 75.5 IXR36V 75.5 IXR46V 75.5 IXR56V 75.5 IXR66V 75.5 IXR80V 75.5 IXR80VT 75.5 IXR110VT 75.5 ※ Above data is subject to modification without notice. 5.2.2. Heat pump installation. ➢ The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid;...
  • Page 17 Installation and user manual ➢ Wiring must be connected by a professional technician according to the circuit diagram. ➢ Set breaker or fuse according to the local code (leakage operating current ≤ 30mA). ➢ The layout of power cable and signal cable should be orderly and not affecting each other. 1.
  • Page 18: Trial After Installation

    Installation and user manual > NOTE: The above data is adapted to power cord ≤ 10m .If power cord is 10m, wire diameter must be increased. The signal cable can be extended to 50m at most. 5.3. Trial after installation Please check all the wirings carefully before turning on the heat pump.
  • Page 19: Trouble Shooting For Common Faults

    Installation and user manual 5.4.2 Winterizing In winter season when you don’t swim, please cut off power supply and drain water out of the heat pump. When using the heat pump under 2℃, make sure there is always water flow. Unscrew the water union of inlet pipe to let the water Important: flow out.
  • Page 20: Failure Code

    Installation and user manual 7. Failure code DISPLAY NOT FAILURE DESCRIPTION No water protection Power supply excesses operation range Excessive temp difference between inlet and outlet water(Insufficient water flow protection) Ambient temperature too high or too low protection Anti-freezing reminder DISPLAY FAILURE DESCRIPTION High pressure protection...
  • Page 21: Appendix 1: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 1: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) - 18 -...
  • Page 22: Appendix 2: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 2: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) - 19 -...
  • Page 23: Appendix 3: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 3: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) - 20 -...
  • Page 24 Installation and user manual Parallel connection with filtration clock Note: The installer should connect A parallel with B (as above picture). To start the water pump, condition A or B is connected. To stop the water pump, both A and B should be disconnected.
  • Page 25: Wifi Setting

    Installation and user manual 8. Wifi setting 1) APP Download Android mobile please download from iphone please download from 2) Account registration a) Registration by Cell phone number/Email - 22 -...
  • Page 26 Installation and user manual b) Cell phone number registration 3) Create family Please set family name and choose the room of device - 23 -...
  • Page 27 Installation and user manual APP Binding Please make sure your cell phone has connected the Wifi a) Wifi connection: Press for 3 seconds after screen unlock, will be flashing to enter Wifi binding program. b) Click "Add device", follow indication to finish binding. display on the screen once Wifi connection success.
  • Page 28 Installation and user manual 5) Operation More share devices Indicate the status of Heating Heating capacity percentage Select ℃/℉ The current swimming pool water temperature The setting temperature Timer Select Turbo/Smart/ Silence Mode On/Off - 25 -...
  • Page 29 Installation and user manual 6) Share devices to your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below: - 26 -...
  • Page 30 Installation and user manual Then your family members can log in as below: Notice: 1. The weather forecast is just for reference. 6. APP is subject to updating without notice. - 27 -...
  • Page 31 Installation and user manual Ithomis Str. 6, Chalandri, GR-15231 Athens - Greece Τel: +30210 6715510 / +30211 7007269/ +30211 7007270 Fax: +302106542877 Website: www.ecofer.com.gr - 28 -...

Table of Contents