SETTING FOR MEASUREMENTS ....................14 Disposal (Directive 2002/96/CE (WEEE)) – When you wish to break up the unit, detach the electrical, electronic, plastic and iron parts. – Proceed to the separated disposal foreseen by the regulations in force. DG83 D CZ sincro...
- 3 - 1.0 FOREWORD The strobotester DG83 D was conceived by SINCRO for checking stroboscopic advance and diagnostic checks on conventional and Gdi petrol engines RPM and advance measurements can be switched on the display by a key in the handgrip, they are independent from the number of cylinders and can be carried out on distributor ignition systems, DIS and coil per plug systems.
Dwell in degrees in points systems, are displayed on display 3 (chap. 4,5,6). See par. ATTENTION on page 7 for checking the wear of each cam. Select the number of sparks per revolution, really existing (Table 1) to • have correct readings. DG83 D CZ sincro...
STROBOSCOPIC IGNITION ADVANCE AND DWELL MEASUREMENT The coil primary cables’ bundle must have 3 wires: + 15, coil negative and return to ground of secondary. TL220 cable + 15 Black TDCmarks aligner Flash key Fig. 5 DG83 D CZ sincro...
Page 7
Should the initial advance correspond to the value stated by the • Manufacturer, and should the engine have cranking problems, check that the distribution belt has not jumped a cog. • Should you use a separate battery, connect the negative pole to the engine ground. DG83 D CZ sincro...
TL 220 cable to the terminal of the AD18 adapter and the inductive clamp to the spark cable of one of the cylinders 5-6. CHECKING CHARGING TIME OF DIS IGNITION COILS OR DWELL Key D + 15 Black AD17 TL 220 cable 12 V Fig. 8 DG83 D CZ sincro...
Page 9
OPEL Calibra V6 Kat and others Cyl. Cyl. (–) Prim. A (–) Prim. A (–) Prim. A (–) Prim. B Sec.1 Sec.1 (–) Prim. B Sec.2 Sec.2 (–) Prim. B (–) Prim. C Sec.3 Fig. 9 DG83 D CZ sincro...
In timed injection systems (ex. IAW Marelli) the check can be carried out by connecting the TL220 cable in sequence to each injector. Fig. 10 INJECTION TIME MEASUREMENT AD16 adapter (optional) Key D TL 220 cable Black Fig. 11 DG83 D CZ sincro...
If peak voltage goes below the values foreseen by the manufacturer (about 1 V at 800 RPM) with the engine at 80°C, replace the sensor. Problems at next cranking at a low temperatures could otherwise occur. DG83 D CZ sincro...
Page 12
14.0 Volts. If voltage does not increase, check the voltage peak V regulator and the alternator. VOLTAGE DROP AT CRANKING AND BATTERY CHARGING VOLTAGE Fig. 16 Black TL220 Cable 12 V Fig. 17 DG83 D CZ sincro...
At engine speeds between 4500 ÷ 6000 RPM, use the stroboscope for frequency 3 ÷ 5 minutes with 1 minute interval to avoid overheating. C ) Triple frequency STROBOSCOPIC RPM MEASUREMENT Fig. 19 Black 12 V Fig. 20 DG83 D CZ sincro...
RPM reading has to be made when the white reference line traced (fig. 25A) is still. Fig. 23 NOTE Follow detailed instructions for each measurement given in the relevant chapters. Reference line DG83-D – KEYS FUNCTION Setting the stroboscopic Reference to increase RPM counter to decrease...