Advertisement

Quick Links

1. Introduction
Brief introduction
1.1.
T90-DTU (900SL22) is a data transceiver with military-grade LoRa modulation technology. With multiple transmission modes, it
works in the (920-925MHz) frequency band. The transceiver provides transparent RS232/RS485 interface and supports 8~. 28V
voltage input. LoRa direct-sequence spread spectrum technology will bring longer communication distances, and has the advantages of
concentrated power density and strong anti-interference ability. It features a software FEC forward error correction algorithm, which
has high coding efficiency and strong error correction capability. In the case of sudden interference, it can proactively correct the
interfered data packets, greatly improving reliability and transmission distance. In the absence of FEC, such packets can only be
discarded. It has data encryption. The data transmitted by the transceiver over the air is random, and the data interception is
meaningless through strict encryption and decryption algorithms. Packet length setting is available to support different real-time and
data packets.
As a communication medium, wireless data transceiver has the same scope as optical fiber, microwave and bright line: it
provides real-time and reliable data transmission of monitoring signals in private networks under certain special conditions, with low
cost, installation and maintenance. It is convenient, has strong diffraction ability, flexible networking structure and long coverage. It is
suitable for occasions with many points and scattered, complex geographical environment, etc. It can be connected with PLC, RTU,
rain gauge, liquid level meter and other data terminals.
Features
1.2.
All core components are imported, featuring the most advanced functions, the smallest volume and the best price.
Using military-grade LoRa modulation technology, with data encryption, the packet length is available for configuration.
Large single package, single package is up to 240 bytes, adapt to Modbus.
Simple and efficient power supply design, support power adapter or crimping mode, support 8~28V power supply.
Transmit power is up to 1W, multi-level adjustable, with all technical indicators meeting European industrial standards.
Support LBT function, the transceiver automatically waits to send data according to the current ambient noise intensity. The
communication success rate of the module in harsh environments is greatly improved.
★ Remotely configure or read wireless module parameters by sending command packets wirelessly.
★ Multi-level relay networking can be realized , which effectively extends communication distance for ultra-long-distance
communication.
★ With temperature compensation circuit, the frequency stability is better than ± 1.5PPM.
★ Operating temperature range: -40 ° C ~ +85 ° C, to adapt to a variety of harsh working environment.
★ All-aluminum alloy casing, compact size, easy installation and good heat dissipation; perfect shielding design, with good
electromagnetic compatibility and strong anti-interference ability.
★Multiple protection functions such as power reverse connection protection, over-current protection, and antenna surge protection
greatly increase the reliability of the device.
★ Powerful software functions, all parameters can be programmed: such as power, frequency, air data rate, address ID, etc.
T90-DTU_User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T90-DTU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TIE T90-DTU

  • Page 1 Brief introduction 1.1. T90-DTU (900SL22) is a data transceiver with military-grade LoRa modulation technology. With multiple transmission modes, it works in the (920-925MHz) frequency band. The transceiver provides transparent RS232/RS485 interface and supports 8~. 28V voltage input. LoRa direct-sequence spread spectrum technology will bring longer communication distances, and has the advantages of concentrated power density and strong anti-interference ability.
  • Page 2: Parts Description

    T90-DTU User Manual ★ Ultra-low power consumption, the standby current is only 10mA (lower than power consumption in power-saving mode and sleep mode), and the transmitting current is ≤0.1A. ★ with built-in watchdog and precise time layout, once an exception occurs, the transceiver will automatically restart, and continue to work according to the previous parameters.
  • Page 3 T90-DTU User Manual 2.2. Dimensions 单位:mm...
  • Page 4: Interface Definition

    8 ~ 28V DC power supply, t is recommended to use 12V or 24V DC power supply for T90-DTU. 3.2. RS232 The T90-DTU can be connected to the device via RS-232 using the standard DB-9 interface. 3.3. RS485 ② T90-DTU can be connected to the 485_A terminal and 485_B terminal from with the RS-485 A terminal and B terminal of other device respectively.
  • Page 5: Technical Specification

    T90-DTU User Manual ★ Note: The transceiver will be in poor communication when connected to multiple devices , it is recommended to be connected to a single device, please try to use parallel 120Ω resistor between 485_A terminal and 485_B.
  • Page 6: Transmitting Power

    T90-DTU User Manual 4.3. Frequency and channel numbers Default Frequency Frequency Range Channel Interval Model No. Channel numbers 81,half duplex T90-DTU 920M 920~925MHz ★ Note: In the same area when multiple data transceivers are communicating one to one at the same time , it is recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
  • Page 7: Function Description

    T90-DTU User Manual 4.7. TX and RX FIFO and sub-packing method Sub-packing method Model No. Buffer Can be sub-packed to 32/64/128/240 byte each time via T90-DTU 1000 bytes command ★ Note:1. When the receiving data is more than a single packet capacity, the beyond part will be automatically assigned to the second transmission until it is completed;...
  • Page 8: Broadcast Transmission

    T90-DTU User Manual Broadcast Transmission 5.2. Broadcast Address 5.3.  For example: Set the address of module A as 0xFFFF and channel as 0x04;  When module A is the transmitter (same mode, transparent transmission), all modules under channel 0x04 will receive the data, the purpose of broadcast is realized.
  • Page 9 T90-DTU User Manual the configuration software on computer. Mode 3 Sleep Mode DTU is in sleep mode. Note: WOR(mode 1) and sleep mode(mode 3) are for low power consumption. If users do not require low power, then it is OK to use mode 0 and mode2 only.
  • Page 10 T90-DTU User Manual Receiving Wireless receiving is off. Configuration Users can visit register to configure the working status. 6.4. Sleep mode(mode 3) M0 = OFF,M1 = OFF,device works in Mode 3 Transmitting Wireless transmission is unavailable. Receiving Wireless receiving is unavailable.
  • Page 11 T90-DTU User Manual Example 1:Set channel as 0x09 command start address length parameter Transmit:C2 Return:C1 Example 2:set module address(0x1234), network address (0x00), UART (9600 8N1), air data rate (1.2K) Transmit:C2 00 04 12 34 00 61 Return:C1 00 04 12 34 00 61 Command:CF CF + general command...
  • Page 12 T90-DTU User Manual 7,6: sub-packing setting  When the data is smaller than the sub packet 00:240byte (Default) length, the serial output of the receiving end is 01:128byte an uninterrupted continuous output. 10:64byte When the data is larger than the sub packet 11:32byte...
  • Page 13 T90-DTU User Manual Users must transmit the first byte within ----------------------------------------------- 1000ms. -------------------------------------- 2,1,0,WOR time  000:500ms Only valid in Mode 1. 001:1000ms  Time T= (1+WOR)*500ms,Max 9000ms, 010:1500ms Min 500ms 011:2000ms(Default)  The longer the WOR monitoring interval 100:2500ms period, the lower the average power 101:3000ms...
  • Page 14: Application Field

    As shown in the figure: the data sent by node 1, the nodes 2, 4 can receive the data sent by node 2, 4, and node 1 can also receive 9. Application field The data transceiver of TIE SMART SOLUTIONS CO,. LTD. is applied for all kinds of point to point, one point to multiple points wireless data transmission system, such as smart home, Internet of things transformation,...
  • Page 15: Operation Notes

    T90-DTU User Manual 10. Operation notes 1. The device may not be operated in the vicinity of some flammable places (such as coal mines) or explosive dangerous objects (such as detonators for detonators). 2. Appropriate DC stabilized power supply should be selected, which requires strong anti-high frequency interference, small ripple, and sufficient load capacity;...
  • Page 16 T90-DTU User Manual FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.