Monogram ZIF361NPRII Installation Instructions Manual
Monogram ZIF361NPRII Installation Instructions Manual

Monogram ZIF361NPRII Installation Instructions Manual

Freezers refrigerators
Hide thumbs Also See for ZIF361NPRII:
Table of Contents

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
18", 24", 30" and 36" Built-In Column Freezers
24", 30" and 36" Built-In Column Refrigerators
Pour obtenir une version française de ce manuel, visitez notre
site web sur monogram.com.
Para consultar una version en español de este manual de instrucciones,
visite nuestro sitio de internet monogram.com.
MONOGRAM.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZIF361NPRII and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Monogram ZIF361NPRII

  • Page 1 18”, 24”, 30” and 36” Built-In Column Freezers 24”, 30” and 36” Built-In Column Refrigerators Pour obtenir une version française de ce manuel, visitez notre site web sur monogram.com. Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet monogram.com. MONOGRAM.COM...
  • Page 2: Safety

    Note to Installer • – Be sure to leave these failure due to improper installation is not covered under instructions with the Consumer. the Monogram Warranty. See the Owner’s Manual for Note to Consumer • – Keep these instructions with warranty information.
  • Page 3 Conservez ces instructions à et plomberie. La responsabilité d’une installation adéquate l’usage de l’inspecteur local. Observez tous les codes et relève de l’installateur. La garantie Monogram ne couvre décrets en vigueur. pas les défectuosités du produit causées par une installation Note à...
  • Page 4 Garantía de • Nota para el Consumidor – Guarde estas Monogram no cubrirá las mismas. Para obtener información instrucciones con su Manual del Propietario para referencia sobre la garantía, consulte el Manual del Propietario.
  • Page 5: Table Of Contents

    Pour le service des Pièces et accessoires Monogram, visitez monogram.com ou 800.444.1845. Pour le service des Pièces et accessoires Monogram au Canada, visitez monogram.ca ou 800.661.1616. Para acceder al servicio local de Monogram en su área, visite monogram.com o 800.444.1845.
  • Page 6: Design Guide

    Design Guide DIMENSIONS AND CLEARANCES Dimensions in parentheses are in centimeters. Overall Dimensions TOP VIEWS DOOR OPEN 90 DOOR OPEN 115 DIMENSIONS BASED ON HANDLE HEIGHT OF 2-9/16” (6.5) FRONT VIEW SIDE VIEW Dimensions 18” Models 24” Models 30” Models 36”...
  • Page 7: Accessories/Kits

    Design Guide situations. Three installation situations will be explained along with door reversal instructions and two options for door panel installation. Reversing the Door Swing (all installation types) Making a refrigerator LH swing and freezer RH swing. MUST be done BEFORE the unit is removed from the ship- ping skid.
  • Page 8: Reversing The Door Swing

    Reversing the Door Swing This step can be done for all installation types. 31-1000600 Rev. 0...
  • Page 9: Step 1 Remove Upper Enclosure

    Installation Instructions - Reversing the Door Swing STEP 1 REMOVE UPPER WARNING Follow all steps when reversing the door ENCLOSURE swing. Failure to follow these instructions, leaving off parts, Compartment Door or overtightening screws, can lead to the door falling off and Open the front cover of Filter result in injury and property damage.
  • Page 10: Step 2 Remove Door

    Installation Instructions - Reversing the Door Swing STEP 2 REMOVE DOOR Remove the 2 T30 Torx screws securing the top hinge to the case. Open the door to the open position. Place the door on a protected work surface (to prevent Have a second person support the open door.
  • Page 11: Step 3 Move Control Assembly

    Installation Instructions - Reversing the Door Swing STEP 3 MOVE CONTROL ASSEMBLY STEP 3 MOVE CONTROL ASSEMBLY Remove upper hinge brackets by removing the T-30 (Cont.) Torx screws. Snap glass assembly back onto the control housing T-30 Torx screws assembly, ensuring plastic pins snap into holes on the side of the housing.
  • Page 12: Step 5 Reinstall Hinge Brackets

    Installation Instructions - Reversing the Door Swing STEP 4 MOVE LIGHT SWITCH STEP 5 REINSTALL HINGE HOUSING (Cont.) BRACKETS Move the mounting bracket to the other side of the Move top hinge bracket to bottom and bottom bracket unit by removing two Philips screws and using them to top.
  • Page 13: Step 7 Reinstall The Front Access Cover

    Installation Instructions - Reversing the Door Swing STEP 6 REINSTALL THE STEP 8 REMOVE HINGES Bottom ENCLOSURE (Cont.) Hinge Cover WARNING Door Hinge Pinch Point Hazard Door hinges are under tension and should be left in the open position throughout the reversal process. Closing the hinge can lead to a finger pinch point hazard.
  • Page 14: Step 10. Reinstall The Door

    Installation Instructions - Reversing the Door Swing STEP 9 REMOVE HINGES FROM STEP 11 REINSTALL THE DOOR DOOR WARNING Move the hinge assembly to Follow all steps when reversing the opposite end of the door the door swing. Failure to follow these instructions, - top hinge to the bottom and leaving off parts, or overtightening screws, can bottom hinge to the top.
  • Page 15: Instructions For Dual Integrated Installation

    Instructions for Dual Integrated Installation New construction installation with 25” deep openings 31-1000600 Rev. 0...
  • Page 16: The Installation Space

    Design Guide - Dual Integrated Installation DUAL INTEGRATED INSTALLATION SPACE Dimensions in parentheses are in centimeters. 25" (63.5) Enclosure Width (See Chart) 6" (15.2) Finished Return 84" (213.4) ELECTRIC WATER 2 1/2" (6.4) ENCLOSURE WIDTH 53 1/2 4 1/8 3 1/2 7 1/2 135.9 10.5...
  • Page 17: Tools, Hardware, Materials

    Design Guide - Dual Integrated Installation DUAL INTEGRATED INSTALLATION SPACE Water And Electrical Locations Additional Specifications Electrical and water supply must be located as shown. • A separate 115 volt 60Hz., 15 or 20 amp power supply is recommended for each product. An individual The Cutout Depth Must Be 25”...
  • Page 18: Grounding The Unit

    Installation Instructions - Dual Integrated Installation KIT ZKUN PARTS SUPPLIED: FLOORING Adhesive Heater For proper installation, this product must be placed on a level surface of hard material that is at the same Transformer height as the rest of the flooring. This surface should Front Mullion be strong enough to support a fully loaded refrigerator Trim Bracket...
  • Page 19: Step 2 Install Water Line

    Installation Instructions - Dual Integrated Installation STEP 1 REMOVE PACKAGING STEP 2 INSTALL WATER LINE Remove front access cover from unit by removing two 1/4” hex head screws. (Some models have access cover in a WARNING ELECTRIC SHOCK HAZARD box on the left side of the cabinet.) Place the cover and screws to the side for future installation.
  • Page 20: Step 3 Preparing Unit For Installation

    Installation Instructions - Dual Integrated Installation STEP 3 PREPARING UNIT FOR STEP 3 PREPARING UNIT FOR INSTALLATION INSTALLATION Unpack the heater Unification Kit (ZKUN) and make Install the transformer into the case top assembly: sure all of the components on the list are included. 1.
  • Page 21: Step 4 Install Anti-Tip Bracket

    Installation Instructions - Dual Integrated Installation STEP 4 INSTALL ANTI-TIP BRACKET STEP 4 INSTALL ANTI-TIP BRACKET (Cont.) WARNING Measure and mark from the RH side of the opening Tip Over Hazard. per the table above depending on the size of the RH These appliances are top heavy, especially with any unit you are installing.
  • Page 22: Step 5 Joining Dual Installed Units

    Installation Instructions - Dual Integrated Installation STEP 5 JOINING DUAL INSTALLED UNITS BOTTOM BACK UNIFICATION TOP UNIFICATION Loosen the two bottom screws of rear access covers of Loosen the front two screws on top of the unit and both units and remove the top screws. remove the two middle screws.
  • Page 23: Step 6 Connecting Water Supply

    Installation Instructions - Dual Integrated Installation STEP 6 CONNECTING WATER STEP 6 CONNECTING WATER SUPPLY SUPPLY Remove strain relief screw to allow for enough slack to make a proper water connection. (Screw must be WARNING ELECTRIC SHOCK HAZARD replaced in the next step.) Attach tubing clamp using existing hole only.
  • Page 24: Step 7 Inserting/Securing Into Cabinet Surround

    Installation Instructions - Dual Integrated Installation STEP 7 INSERTING/SECURING STEP 7 INSERTING/SECURING INTO CABINET SURROUND INTO CABINET SURROUND WARNING Electrical Shock Hazard. WARNING Tip Over Hazard. To reduce the risk of electrical shock, be careful during the These appliances are top heavy, especially with remaining installation steps not to touch wiring or electrical any doors open, and must be secured to prevent components inside the compressor compartment while the...
  • Page 25: Step 8 Level Unit

    Installation Instructions - Dual Integrated Installation STEP 7 INSERTING/SECURING STEP 8 LEVEL UNIT INTO CABINET SURROUND (Cont.) All models have 4-point leveling. The front is supported Replace the waterline strain relief screw. by leveling legs; the rear is supported by adjustable wheels.
  • Page 26: Step 9 Final External Unit Preparation

    Installation Instructions - Dual Integrated Installation STEP 9 FINAL EXTERNAL UNIT STEP 9 FINAL EXTERNAL UNIT PREPARATION (Cont.) PREPARATION FOR FLUSH INSTALLATION: Make sure front surface 1/4” Hex Screws of the door is 7/8” behind front face of surrounding cabinets BEFORE securing brackets to the surrounding Compartment Door cabinetry.
  • Page 27: Step 10 Toe Kick Installation

    Installation Instructions - Dual Integrated Installation STEP 9 FINAL EXTERNAL UNIT STEP 11 INTERNAL UNIT PREPARATION (Cont.) PREPARATION Install front mullion and access cover trims between Remove all tape, cardboard, and foam from each unit the 2 units. Open the doors and the flexible dart in (foam shipping supports may be located behind the the area between units.
  • Page 28: Step 12 Start Icemaker

    Installation Instructions - Dual Integrated Installation STEP 12 START ICEMAKER STEP 12 START ICEMAKER (freezer models) (freezer models) When the freezer has been connected to the water supply, set the power switch to ON. CAUTION To minimize the risk of personal Throw away the first full bucket of ice to allow the water injury, avoid contact with the moving parts of the line to clear.
  • Page 29: Step 13 Install Autofill Pitcher Assembly

    Installation Instructions - Dual Integrated Installation STEP 13 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of the Conceal wires and tubing inside the wall compartment refrigerator’s interior. Remove T20 Torx screw holding and place the AutoFill wall assembly onto the forward the cover in place towards the rear of the cover.
  • Page 30: Instructions For Retro-Fit Installation

    Instructions for Retro-Fit Installation Existing construction installation with 24” deep openings that are 35-1/2”, 36”, 41-1/2”, 47-1/2” or 71-1/2” wide 31-1000600 Rev. 0...
  • Page 31: The Installation Space

    Design Guide - Dual Retro-Fit Installation DUAL RETRO-FIT INSTALLATION SPACE Dimensions in parentheses are in centimeters. 24" (61.0) Enclosure Width 6" Electric Location (15.2) 6" Finished (15.2) Return 5" (12.7) *83 1/2" min. *84 1/2" max. 75" (212.1 – 214.6) (190.5) *Trim will overlap additional 5/8"...
  • Page 32: Tools, Hardware, Materials

    Installation Instructions - Dual Retro-Fit Installation REFRIGERATOR/FREEZER LOCATION GROUNDING THE UNIT Do not install the refrigerator/freezer where the temperature WARNING will go below 55°F (13°C). It will not run often enough to Electrical Shock maintain proper temperatures. Hazard. Failure to follow these instructions can result Do not install the refrigerator/freezer where temperatures in death, fire, or electrical shock.
  • Page 33: Step 1 Remove Packaging

    Installation Instructions - Dual Retro-Fit Installation KIT ZKUN PARTS SUPPLIED: STEP 1 REMOVE PACKAGING Adhesive Heater Remove hardware kit from top drawer. If installation requires a 90° door opening, the hinge Transformer limiter pin must be installed in the top hinge BEFORE Front Mullion the unit is removed from the...
  • Page 34: Step 2 Install Water Line

    Installation Instructions - Dual Retro-Fit Installation STEP 2 INSTALL WATER LINE STEP 2 INSTALL WATER LINE (Cont.) WARNING Connect to potable water supply NOTE: Saddle type shut-off valves are included in only. A cold water supply is required for automatic many water supply kits.
  • Page 35: Step 3 Preparing Unit For Installation

    Installation Instructions - Dual Retro-Fit Installation STEP 3 PREPARING UNIT FOR STEP 3 PREPARING UNIT FOR INSTALLATION INSTALLATION Unpack the heater Unification Kit (ZKUN) and make WARNING sure all of the components on the list are included. Electrical Shock NOTE: Ensure the heater connector cord is toward the Hazard.
  • Page 36: Step 4 Install Anti-Tip Bracket

    Installation Instructions - Dual Retro-Fit Installation STEP 4 INSTALL ANTI-TIP BRACKET Measure and mark from the RH side of the opening per the table above depending on the size of the RH unit WARNING you are installing. Tip Over Hazard. These appliances are top heavy, especially with any doors open, and must be secured to prevent tipping forward which could result in death or seri-...
  • Page 37: Step 5 Joining Dual Installed Units

    Installation Instructions - Dual Retro-Fit Installation STEP 5 JOINING DUAL INSTALLED UNITS BOTTOM BACK UNIFICATION TOP UNIFICATION Loosen the two bottom screws of rear access covers of both units and remove the top screws. screws. Hang the unification bracket to the bottom screws and reassemble the screws at the top reassemble the rear screws.
  • Page 38 Installation Instructions - Dual Retro-Fit Installation STEP 5 JOINING DUAL INSTALLED UNITS (Cont.) Replace rear access cover. Make sure the power CHANGE POWER CORD cord and ground wire are properly routed through the Longer power cords are required for retro fit installation. access cover cut-out.
  • Page 39: Step 6 Connecting Water Supply

    Installation Instructions - Dual Retro-Fit Installation STEP 5 JOINING DUAL INSTALLED STEP 6 CONNECTING WATER UNITS (Cont.) SUPPLY CASE TRIM INSTALLATION WARNING Connect to potable water supply Fit the top trim and side trim rails together by sliding only. A cold water supply is required for automatic the exposed edges of the corner trim into the right icemaker operation.
  • Page 40: Step 7 Inserting/Securing Into Cabinet Surround

    Installation Instructions - Dual Retro-Fit Installation STEP 6 CONNECTING WATER STEP 7 INSERTING/SECURING INTO SUPPLY CABINET SURROUND Plug both units to the outlet in the wall. Locate and bring the tubing to the front of the cabinet. Turn the water on to flush debris from the line. Run about a quart of water through the tubing into a WARNING Electrical Shock Hazard.
  • Page 41 Installation Instructions - Dual Retro-Fit Installation STEP 7 INSERTING/SECURING INTO STEP 7 INSERTING/SECURING INTO CABINET SURROUND CABINET SURROUND Slowly walk both units into opening making sure not Replace the waterline strain relief screw. to touch the cabinetry on the sides and top to prevent Strain Relief damage.
  • Page 42: Step 8 Level Unit

    Installation Instructions - Dual Retro-Fit Installation STEP 9 FINAL EXTERNAL UNIT STEP 8 LEVEL UNIT PREPARATION (Cont.) All models have 4-point leveling. The front is supported by leveling legs; the rear is supported by adjustable Make sure lights are on inside the unit. If they are not wheels.
  • Page 43 Installation Instructions - Dual Retro-Fit Installation STEP 9 FINAL EXTERNAL UNIT PREPARATION (Cont.) For proper case placement after leveling, the back side Put the access cover back onto the unit and secure with of the top and side retro trims should be flush with the two 1/4”...
  • Page 44: Step 10 Toe Kick Installation

    Installation Instructions - Dual Retro-Fit Installation STEP 12 START ICEMAKER STEP 10 TOE KICK INSTALLATION (freezer models) Insert Toe Kick into the slot in the Front Access Cover by rotating it toward you. A newly-installed freezer may take 12–24 hours to Push the bottom begin making ice.
  • Page 45: Step 13 Install Autofill Pitcher Assembly

    Installation Instructions - Dual Retro-Fit Installation STEP 13 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of the Conceal wires and tubing inside the wall compartment refrigerator’s interior. Remove T20 Torx screw holding and place the AutoFill assembly onto the forward end the cover in place towards the rear of the cover.
  • Page 46: Instructions For Single Integrated Installation

    Instructions for Single Integrated Installation New construction installation with 25” deep openings 31-1000600 Rev. 0...
  • Page 47: The Installation Space

    Design Guide - Single Integrated Installation SINGLE INTEGRATED INSTALLATION SPACE Dimensions in parentheses are in centimeters. 25" (63.5) Enclosure Width (See Chart) 6" (15.2) Finished Return 84" (213.4) ELECTRIC WATER 2 1/2" (6.4) Water And Electrical Locations Electrical and water supply must be located as shown. PRODUCT ENCLOSURE WIDTH...
  • Page 48: Tools, Hardware, Materials

    Installation Instructions - Single Integrated Installation REFRIGERATOR/FREEZER LOCATION GROUNDING THE UNIT Do not install the refrigerator/freezer where the tem- perature will go below 55°F (13°C). It will not run WARNING often enough to maintain proper temperatures. Electrical Shock Do not install the refrigerator/freezer where Hazard.
  • Page 49: Step 1 Remove Packaging

    Installation Instructions - Single Integrated Installation HARDWARE SUPPLIED (per unit) STEP 1 REMOVE PACKAGING • Water Filter Bypass Plug (if equipped) • Air filter (if equipped) WARNING Tip Over Hazard. • Anti-Tip bracket (qty 2 for 36”) These appliances are top heavy, especially with any •...
  • Page 50: Step 2 Install Water Line

    Installation Instructions - Single Integrated Installation STEP 1 REMOVE PACKAGING (Cont.) Remove front access cover from unit by removing 3/8” Drive two 1/4” hex head screws (some models have access Screws cover in a box on the left side of the cabinet). Place the cover and screws to the side for future installation.
  • Page 51: Step 3 Preparing Unit For Installation

    Installation Instructions - Single Integrated Installation STEP 3 PREPARING UNIT FOR STEP 4 INSTALL ANTI-TIP BRACKET Measure and mark from the right side of the opening INSTALLATION per the table depending on the size of the unit you Place the unit in front of the installation opening in a are installing.
  • Page 52: Step 5. Connecting Water Supply

    Installation Instructions - Single Integrated Installation STEP 5 CONNECT WATER SUPPLY STEP 5 CONNECT WATER SUPPLY WARNING Connect to potable water supply only. A cold water supply is required for automatic icemaker operation. The water pressure must be between 40 and 120 psi (275-827 kilopascals). Refrigerator/ House Freezer...
  • Page 53: Step 6 Inserting/Securing Into Cabinet Surround

    Installation Instructions - Single Integrated Installation STEP 6 INSERTING/SECURING STEP 6 INSERTING/SECURING INTO CABINET SURROUND INTO CABINET SURROUND Plug unit into the outlet in the wall. Slowly walk the unit into opening making sure not to touch the cabinetry on the sides and top to prevent damage.
  • Page 54: Step 7 Level Unit

    Installation Instructions - Single Integrated Installation STEP 7 LEVEL UNIT STEP 6 INSERTING/SECURING INTO CABINET SURROUND NOTICE: The rear leveling wheels and front leveling legs are limited to a maximum height adjustment of 1”. As you walk the unit back into the opening, you should pull the string tight to make sure the power If the installation requires more than 84”...
  • Page 55: Step 9 Toe Kick Installation

    Installation Instructions - Single Integrated Installation STEP 8 FINAL EXTERNAL UNIT STEP 8 FINAL EXTERNAL UNIT PREPARATION (Cont.) PREPARATION (Cont.) Make sure lights are on inside the unit. If they are not Put the access cover back onto the unit and secure on, check to make sure the master switch is on by with two 1/4”...
  • Page 56: Step 11. Start Icemaker

    Installation Instructions - Single Integrated Installation STEP 11 START ICEMAKER (freezer models) If the freezer is operated before the water connection is made to the icemaker, set the power switch to OFF. Top CAUTION To minimize the risk of personal wire basket must be removed to access the icemaker injury, avoid contact with the moving parts of the power switch.
  • Page 57: Step 12 Install Autofill Pitcher Assembly

    Installation Instructions - Single Integrated Installation STEP 12 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of Conceal wires and tubing inside the wall compartment the refrigerator’s interior. Remove the one T20 Torx and place the AutoFill assembly onto the forward end screw holding the cover in place towards the rear of of the mount until flush with the interior wall of the...
  • Page 58: Stainless Steel Door Panel Installation

    Stainless Steel Door Panel Installation This step can be done for all installation types. 31-1000600 Rev. 0...
  • Page 59: Step 1 Install Stainless Panel

    Installation Instructions - Stainless Door Panel Stainless Steel Door Panel Kits are available with either STEP 1 INSTALL STAINLESS PANEL Euro handles or Pro handles. Remove bottom hinge cover and retain the 4 T30 ZK1SN189NLH LH 18” Stainless Steel Door Panel Torx screws for later installation.
  • Page 60 Installation Instructions - Stainless Door Panel STEP 2 ADJUST STAINLESS PANEL (Cont.) Follow the next steps for set screw installation. If the panels do not lay flat, they can be adjusted. Start by adjusting the top corners and then moving For flush mounting, inspect the gap between the panel to the bottom corners.
  • Page 61: Step 3. If Doors Reversed Complete Steps

    Installation Instructions - Stainless Door Panel STEP 3 IF DOORS WERE REVERSED COMPLETE THE FOLLOWING STEPS Top cover assembly shipped in box on side of product. Remove screws and nuts to remove rectangular cover. Retain parts to build new top assembly. Mount rectangular cover to bottom cover (removed during door reversal) utilizing the screws and nuts that were removed from top assembly.
  • Page 62: Step 4. Install Door Trims

    Installation Instructions - Stainless Door Panel STEP 5 INSTALL DOOR TRIMS There are 2 door trims to install. One for the handle Without touching the exposed tape to the side of side and one for the hinge side. The long trim is for the the door, align the top of the trim with the top of the handle side and the shorter trim is for the hinge side.
  • Page 63: Custom Overlay Door Panel Installation

    Custom Overlay Door Panel Installation This step can be done for all installation types. 31-1000600 Rev. 0...
  • Page 64: Custom Handle Design Guide

    Design Guide - Custom Overlay Door Panel CUSTOM HANDLE DESIGN GUIDE Custom handles must be used for flush installation. For Minimum distance from 1-1/2” custom handle installation, counter-bore holes in rear of panel side edge to decorative panels must ensure 1/2” (1.27cm) material handle center should thickness remains for handle support.
  • Page 65: Step 1 Overlay Panel Prep

    Installation Instructions - Custom Overlay Door Panel STEP 1 OVERLAY PANEL PREP Verify overall panel dimensions match supplied Install center mounting brackets with 2 #6 Phillips head recommendations based on model and inspect for any screws. initial damage. Install the top center mounting bracket and secure with Lay the template on the BACK of the panel, making 2 #6 Philips screw.
  • Page 66: Step 2 Install Overlay Panel

    Installation Instructions - Custom Overlay Door Panel STEP 3 ADJUST OVERLAY PANEL STEP 2 INSTALL OVERLAY PANEL (Cont.) Remove bottom hinge cover and retain the 4 T30 Torx screws for later installation. Follow the next steps for set screw installation. For flush mounting, inspect the gap between the panel and cabinetry at the handle side.
  • Page 67: Step 3. Adjust Overlay Panel

    Installation Instructions - Custom Overlay Door Panel STEP 3 ADJUST OVERLAY PANEL (Cont.) After the panel has been adjusted to the desired position, secure the panel by first driving and tightening Center the vertical screws at the bottom of the door brackets Mounting Bracket and then drive and tighten the remaining horizontal...
  • Page 68: Step 4. Install Hinge Covers

    Installation Instructions - Custom Overlay Door Panel STEP 5 INSTALL HINGE COVERS STEP 6 INSTALL DOOR TRIMS Replace the top and bottom hinge covers using There are 2 door trims to install. One for the handle 4-T30 screws per cover. side and one for the hinge side.
  • Page 69 Installation Instructions - Custom Overlay Door Panel STEP 6 INSTALL DOOR TRIMS (cont.) Without touching the exposed tape to the side of the 1. Gently pull the top of the outer trim away from the door, align the top of the trim door panel in order to expose the tape backer.
  • Page 70 Notes 31-1000600 Rev. 0...
  • Page 71 Notes 31-1000600 Rev. 0...
  • Page 72 NOTE: While performing installations described in this book, safety glasses or goggles should be worn. NOTE: Product improvement is a continuing endeavor at Monogram. Therefore, materials, appearance and specifications are subject to change without notice. 31-100600 Rev. 0 07-21 GEA...

Table of Contents