Grass Valley hereby grants permission and license to owners of IPG-4901 to use their product manuals for their own internal business use. Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose unless specifically authorized in writing by Grass Valley.
Page 3
来源于公司外部,我们无法保证它的完整和准确。所有这些特性可能在未获通知的情况下更改。 Technical explanations: This statement is based on the information provided by our suppliers of components and collected through Grass Valley’s environmental management system. Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy as it is based on data received from sources outside our company. All specifications are subject to change without notice.
Page 4
EN 61000-4-2 Electrostatic discharge immunity • EN 61000-4-3 Radiated electromagnetic field immunity – RF • EN 61000-4-4 EFT immunity • EN 61000-4-5 Surge immunity • EN 61000-4-6 Conducted immunity • EN 61000-4-8 EMP immunity • EN 61000-4-11 Voltage-dips, short-interruption and voltage variation immunity IPG-4901...
4.2.2 Gateway Config window ...................... 11 4.2.3 Gateway – IN tab ......................... 17 4.2.4 How to set up the timing on the IPG-4901 ................19 4.2.5 Gateway – System tab ......................20 Network panel ........................... 21 4.3.1 Network panel – Settings tab ....................21 4.3.2...
Page 6
GUIDE TO INSTALLATION AND OPERATION ANNEX 2 – Firmware upgrade ....................41 IPG-4901...
Alignment capability provides a clean switching of any of the sources from the IPG-4901. The IPG-4901 I/O module may be combined in the same chassis with other GV Node or GV Matrix modules to create an even more versatile distributed edge-routing node.
GUIDE TO INSTALLATION AND OPERATION • Compatible with GV Node and GV Matrix platforms. • Configured and controlled by Grass Valley’s GV Convergent SDN platform, or by the proven iControl system. • Uses Universal Reference Signal from the frame controller. 1.3 Functional Block Diagrams Figure 1-1 IPG-4901 Functional Block Diagram –...
The local control panel on the GV Node can be used to move through a menu of status reports and parameter settings (see section • Grass Valley’s iControl system can be used to access the card’s operating parameters from a remote computer, using a convenient graphical user interface (GUI) (see section IPG-4901 | 3...
Once the rear connector panel is in place, install the IPG-4901 card as follows: 1. Open the front door of the GV Node frame. 2. Slide the IPG-4901 card into the slot (swivel handle at the top) and push gently on the handle to seat the connectors.
The GV Node’s local control panel is fastened to the front of the controller card, and accessed through an aperture in the frame door. To access the menu for this IPG-4901, touch the virtual button corresponding to the card (identified by card type and slot number) in the home screen.
GUIDE TO INSTALLATION AND OPERATION 3.1 Status Monitoring The status of the IPG-4901 is reported by the outline of the card’s access button in the home page. The outline’s color indicates error status: To determine the type of error that causes the error status, select the card and scroll down the status items in the menu.
4.1 The iControl graphic interface window The basic window structure for the IPG-4901 is shown in figure 5.1. The window identification line gives the card type (IPG-4901) and the slot number where the card is installed in its Densité frame.
Page 14
At least one SDI input from fabric is in error. Reference mismatch. Video/TRS error. (red) Icon #4 – Reference Status Reference present, supported and locked. (green) Reference missing. Unsupported format or format mismatch. (red) Not locked. No reference. (gray) 8 | IPG-4901...
Page 15
Operation mode: process – normal processing of the input signal. (green) Operation mode: Enabled, but no signal to process. (yellow) Operation mode: TEST – color bar and audio test tones enabled on at least one gateway. (yellow) IPG-4901 | 9...
The Gateway panel provides resources for configuring and managing the gateways on the IPG-4901. Figure 4-2 Gateway panel – upper portion The Gateway Status icons at the top of the panel show the current status of all eighteen gateways on the IPG-4901: •...
See page 34 for instructions. 4.2.2 Gateway Config window This window shows the current configuration and status of all gateways on the card, and provides controls to modify their settings. Figure 4-3 Gateway Config table IPG-4901 | 11...
Page 18
There are nine OUT gateways that connect the fabric output to the rear-panel IP stream outputs: • There are nine IN gateways that connect the rear-panel IP streams to the GV Node fabric inputs: Fabric-to-IP Gateway (OUT) Gateways 1 - 9 IP-to-fabric gateway (IN) Gateways 10 - 18 12 | IPG-4901...
Page 19
When receiving unicast streams, IGMPv3 • protocol is not used. When this field is set to 0.0.0.0, IGMPv3 • protocol will request multicast streams for all sources. IPG-4901 | 13...
Page 20
GUIDE TO INSTALLATION AND OPERATION Stream Formats You may independently enable or disable the two streaming types supported by the IPG-4901, using the EN checkboxes for each gateway: • SMPTE 2022-6 Video with embedded audio • AES-67 Multichannel AES audio NOTE –...
Page 21
When you have entered new values into the table that do not trigger immediate changes (you can change multiple parameters on different gateways), the changed values are highlighted, and the Apply and Cancel buttons at the top of the table are active. IPG-4901 | 15...
Page 22
Incoming SDI Video does not match gateway format. SDI from fabric scan rate error. Grey Gateway is disabled. OUT from fabric to Green SDI input present and valid. IP Stream No SDI from fabric. SDI from fabric not valid. Grey Gateway disabled. 16 | IPG-4901...
This is the default mode. Group Sync (TR-04) Video and audio are synced together. Both streams must have valid RTP timestamps inserted for correct alignment according to TR-04. Only the Video Config controls are active; the AES-67 controls are disabled. IPG-4901 | 17...
Page 24
Present and valid Value “N/A” Redundancy Value Value Aggregation ETH1 Value “N/A” ETH2 “N/A” Value Not present or not valid “N/A” “N/A” An In Range indicator shows status by color. See the Configuration section below for details. 18 | IPG-4901...
This applied link offset value is displayed in the Status area of the panel, beside the AES-67 link Latency status. Video and audio are automatically aligned. 4.2.4 How to set up the timing on the IPG-4901 AES-67 Timing You can use the values presented in the ETH1 and ETH2 Link Latency displays, in conjunction with the following information, to calculate the minimum value for the Link Offset.
Note that the IN RANGE status must be GREEN for audio to be inserted in the SDI output. 4.2.5 Gateway – System tab Figure 4-6 Gateway - System 20 | IPG-4901...
4.3 Network panel 4.3.1 Network panel – Settings tab Network Configuration Enter the IP Address, Mask and Gateway for the two ethernet ports (ETH1 and ETH2) on the IPG-4901 into the data boxes. • After any change, you must click Apply to confirm the new values, or Cancel to leave the existing values unchanged.
Each port has a separate MAC Address address, factory-set and non- configurable. It also reports the status of SFP modules installed in the IPG-4901 rear panel. Status Details Presence Green – Supported SFP module Figure 4-8 Network panel – Status tab detected Grey –...
The reference may be available in 50 Hz and/or 59.94 Hz – a green icon indicates the presence of each format. 4.4.2 Reference Panel – PTP tab IPG-4901 extracts PTP (Precision Time Protocol) data for streaming (RTP Timestamp) and AES-67 reception. The card still needs the GV Node’s URS reference.
Page 30
Status Present & locked Not present Not locked Master ID: Reports the address of the master clock to which this IPG-4901 is synchronized. Step: Reports whether the timing is being controlled through a 1-step or 2-step process. 24 | IPG-4901...
4.4.3 PTP Failover In general, the PTP arriving on ETH1 port is used by the IPG-4901. If the PTP on ETH1 is lost, the card will enter Flywheel mode, and then switch over to the PTP from ETH2 once the Announce Receipt Timeout has been reached.
A confirmation box will pop up to allow you to proceed or cancel the load. Click Save to store the current parameter settings and values from the IPG-4901 into the selected User Preset. The existing contents of the preset will be overwritten. A confirmation box will pop up to allow you to proceed or cancel the save.
Figure 4-14 Profile Copy for Card Copy profile from This line shows this IPG-4901 card, and identifies it by App server, Densité frame and slot number, card type and firmware version. The Profile column has a pulldown that allows you to select which profiles you will work with, and gives these choices: •...
Page 34
• If the file was not saved for some reason, the Transfer Status box will indicate Failed against a red background. Restore profile from disk… Click this button to open an Open dialog box within which you can locate and select a valid IPG-4901 profile file. • Click Open to read the contents of the file and to reconfigure this IPG-4901’s profiles according to its...
N/A on a yellow background 4.7 Alarm Config Panel This panel allows the alarm reporting of the IPG-4901 to be configured. The panel opens in a new window when the button is clicked, and can be resized if needed.
Page 36
Log Events iControl maintains a log of alarm events associated with the card. The log is useful for troubleshooting and identifying event sequences. Click in the checkbox to enable logging of alarm events for each individual alarm. 30 | IPG-4901...
Page 37
All checkbox • Note that when you copy a profile for this card (see page 27), the alarm configuration is copied along with all the other settings. Figure 4-19 Copy to Other Cards window IPG-4901 | 31...
Cancel closes the window without applying any changes, and leaves the previous settings intact. 4.8 Info Panel 4.8.1 Info Panel – Info tab When the IPG-4901 is included in an iControl environment, certain information about the card should be available to the iControl system. The user can enter labels and comments that will make this card easy to identify in a complex setup.
Page 39
• Remote System Administration – opens the Joining Locators window, which lists remote lookup services to which this IPG-4901 is registered Add: Force the iControl service for this IPG-4901 to register itself on a user-specified Jini lookup service, using the following syntax in the data box: jini://<ip_address>...
Figure 4-25 Info Panel - Technical Support tab 5 GV Node Manager Because IPG-4901 is a card dedicated to GV Node, it appears in the GV Node Manager, and some aspects of its operation can be controlled from there. See the GV Node User Manual for a full explanation of the GV Node Manager’s features and functionality.
Page 41
GUIDE TO INSTALLATION AND OPERATION For the IPG-4901: Each IPG-4901 IN and OUT presents a pulldown in the GV Node Manager window. The pulldown sets the status of the associated gateway. • The setting of this pulldown determines whether 2022-6 and AES67 streams can be enabled in the...
ST 2022-7 seamless protection Performance: Up to 9 Gb of streaming per direction Electrical Power: 30 W maximum * 3G level A signaling currently supported. 3G level B signaling will be supported at a later date with a firmware update 36 | IPG-4901...
GUIDE TO INSTALLATION AND OPERATION 7 Contact Us Grass Valley Technical Support For technical assistance, contact our international support center, at 1-800-547-8949 (US and Canada) or +1 530 478 4148. To obtain a local phone number for the support center nearest you, please consult the Contact Us section of Grass Valley’s website (www.grassvalley.com).
HARDWARE HARDWARE OK HARDWARE FAILURE FAN OK FAN FAILURE TEMPERATURE TEMPERATURE OK TEMPERATURE FAILURE CARD PRESET LOAD <name> Loads the user preset selected. <name> is the preset name SAVE <name> Save the user preset in the preset 38 | IPG-4901...
Page 45
SOURCE AUTO AUTO EXTERNAL NO REF DOMAIN 0 to 127 INTERVAL 0.125s, 0.25s, 0.5s, 1s, 2s 0.125s For AES-67 profiles: 4s, 8s, 16s RECEIPT 2 to 10 TIMEOUT TEST PATTERN FORMAT 1080p 1080i 1080i 720p FORCE ALL IPG-4901 | 39...
Page 46
134 xxxx FPGA Version of the FPGA BUILD: xxx FACTORY DEFAULT WITHOUT APPLY If selected, everything but network NETWORK configuration is restored to factory INCLUDE APPLY If selected, everything is factory NETWORK defaulted. 40 | IPG-4901...
Page 47
GUIDE TO INSTALLATION AND OPERATION ANNEX 2 – Firmware upgrade Upgrade both firmware and IControl service using the Densité Upgrade Manager (DUM). Please consult the iControl User’s Guide for information about the iControl Densité Upgrade Manager. IPG-4901 | 41...