SENSY DISP-FP Series Manual

Large digit process indicator / controller

Advertisement

Quick Links

LARGE DIGIT PROCESS INDICATOR / CONTROLLER
DISP-FP4x (4 digits)
1. WARNINGS .........................................................................................................................................................................................2
2. INTRODUCTION .................................................................................................................................................................................3
3. GENERAL DESCRIPTION ..................................................................................................................................................................4
4. CONNECTIONS ..................................................................................................................................................................................5
4.1. Power Board ................................................................................................................................................................................5
4.2. Signal ..........................................................................................................................................................................................6
4.3. Remote ........................................................................................................................................................................................6
5. DISPLAY BRIGHTNESS .....................................................................................................................................................................7
6. METER CALIBRATION .......................................................................................................................................................................7
6.1. Direct Calibration .........................................................................................................................................................................8
6.1.1. Full Scale Setting ................................................................................................................................................................8
6.1.2. Zero Setting .........................................................................................................................................................................9
6.2. Theoretical Calibration ..............................................................................................................................................................10
6.2.1. Decimal Point & Full Scale ................................................................................................................................................10
6.2.2. Low end calibration ...........................................................................................................................................................11
7. SIGNAL FILTERING / AVERAGING .................................................................................................................................................12
8. LAST DIGIT ROUNDING UP BY 1, 2, 5, 10, 20 OR 50 ....................................................................................................................12
9. ERROR CODES AND FAULT FINDING ...........................................................................................................................................13
10. WASTE ELECTRICAL ELECTRONIC EQUIPMENT (WEEE) ........................................................................................................14
11. EQUIPMENT SPECIFICATIONS ....................................................................................................................................................15
12. DIAGRAM OF THE SETUP MENUS ...............................................................................................................................................16
12.1. Parameters ..............................................................................................................................................................................16
12.2. Meter calibration modes ..........................................................................................................................................................16
12.3. DIRECT calibration - Full scale setting / Zero setting .............................................................................................................16
12.4. THEORETICAL - Full scale setting / Zero setting ..................................................................................................................17
12.5. Moving the decimal .................................................................................................................................................................17
12.6. Tare .........................................................................................................................................................................................17
13. CERTIFICATE OF CE CONFORMITY ............................................................................................................................................18
MA-DISP-FP4x & 6x_EN
DISP-FPXX
Page 1 on 18
DISP-FP6x (6 digits)
Rev: 08/02/2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DISP-FP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SENSY DISP-FP Series

  • Page 1: Table Of Contents

    DISP-FPXX LARGE DIGIT PROCESS INDICATOR / CONTROLLER DISP-FP4x (4 digits) DISP-FP6x (6 digits) 1. WARNINGS ......................................2 2. INTRODUCTION ....................................3 3. GENERAL DESCRIPTION ..................................4 4. CONNECTIONS ....................................5 4.1. Power Board ....................................5 4.2. Signal ......................................6 4.3. Remote ......................................6 5. DISPLAY BRIGHTNESS ..................................7 6.
  • Page 2: Warnings

    1. WARNINGS Please carefully read this manual and all warnings. Install the display ONLY when you are sure that you‟ve covered all aspects. Where the product is intended for “UL” installations, removal or addition of option boards is not permitted. Check that the model number and supply voltage suit your application before you install the display.
  • Page 3: Introduction

    2. INTRODUCTION Please contact us if you need help, if you have a complaint, or if you have suggestions to help us improve our products or services. If you contact us about a product you already have, please tell us the full model number and serial number, so that we can give you accurate and fast help.
  • Page 4: General Description

    3. GENERAL DESCRIPTION The main function of this series is to give a clear numeric readout of the variable being monitored. Various digit heights are available, to suit the maximum viewing distance required in each installation. For every 10 metres of viewing distance required, use 1” (2,54cm) of digit height. Various optional output modules are also available to give alarm relay outputs, analogue output or digital communications, or any combination of these options.
  • Page 5: Connections

    4. CONNECTIONS Warning: Disconnect all power before removing the rear of the display There is a wide range of possible locations for the input board, output board and power supply board/s. Their locations depend on the height of digits, number of digits, brightness of digits and any installed options. Because the permutation of possible locations is large, we will not describe the location of boards within the display, but simply identify the connectors and their functions on each board.
  • Page 6: Signal

    4.2. Signal There are only two wires for the signal: The Signal – is the terminal number 2. The Signal mA+ is the terminal number 3. You can connect the shielding of the signal cable to the terminal number 7 (Common of the Logic Inputs) The fourth is the Signal V+.
  • Page 7: Display Brightness

    5. DISPLAY BRIGHTNESS You can adjust the display brightness at any time, provided the display is locked. DISP-FP4x (4 digits) DISP-FP6x (6 digits) 6. METER CALIBRATION You can choose from two main calibration methods. 1. Direct Calibration – calibration that needs a load that the display will measure. This is the preferred calibration method, because it allows you to calibrate the system as a whole.
  • Page 8: Direct Calibration

    DISP-FP4x (4 digits) DISP-FP6x (6 digits) 6.1. Direct Calibration If you have not done so before, please select Direct Calibration mode from the Meter Calibration Mode at the page 7. First we recommend you set the FULL SCALE calibration. 6.1.1. Full Scale Setting Setting the high point of the calibration: DISP-FP4x (4 digits) DISP-FP6x (6 digits)
  • Page 9: Zero Setting

    6.1.2. Zero Setting Setting the „ZERO‟ point of the calibration. DISP-FP4x (4 digits) DISP-FP6x (6 digits) MA-DISP-FP4x & 6x_EN Page 9 on 18 Rev: 08/02/2012...
  • Page 10: Theoretical Calibration

    6.2. Theoretical Calibration If you have not done so before, please select Direct Calibration mode from the Meter Calibration Mode at the page 7. First we recommend you set the FULL SCALE calibration. 6.2.1. Decimal Point & Full Scale Setting the high point of the calibration DISP-FP4x (4 digits) DISP-FP6x (6 digits) MA-DISP-FP4x &...
  • Page 11: Low End Calibration

    6.2.2. Low end calibration Setting the „ZERO‟ point of the calibration DISP-FP4x (4 digits) DISP-FP6x (6 digits) MA-DISP-FP4x & 6x_EN Page 11 on 18 Rev: 08/02/2012...
  • Page 12: Signal Filtering / Averaging

    7. SIGNAL FILTERING / AVERAGING You can adjust the filtering time constant to reduce the effect of noise or instability on your input signal. A larger FIL value will give a more stable display, but the response to signal changes will be slower. DISP-FP4x (4 digits) DISP-FP6x (6 digits) 8.
  • Page 13: Error Codes And Fault Finding

    9. ERROR CODES AND FAULT FINDING 1. Under Range. The meter is being asked to display a value which is more negative than its limit of -199999 2. Over Range. The meter is being asked to display a value which is higher than its limit of 999999 These fault codes could be displayed because the signal is too negative, too positive, or because there is a wiring error, or because the display‟s scaling has been adjusted to give excessive sensitivity, or because there...
  • Page 14: Waste Electrical Electronic Equipment (Weee)

    10. WASTE ELECTRICAL ELECTRONIC EQUIPMENT (WEEE) In Europe, this equipment must be disposed of in accordance with European Parliamentary Directive 2002/96/EC This directive encourages recycling and the reduction of waste materials in the environment. This means it must be sent to an approved recycling plant if you want to dispose of it. It must not be thrown away with general rubbish.
  • Page 15: Equipment Specifications

    11. EQUIPMENT SPECIFICATIONS Case Material Heavy duty welded uPVC Connectors Internal detachable Screw Terminal connectors accessed via compression glands Environmental Storage Temperature range: -20 to +70C, non condensing Operating temperature range: 0 to 50°C. Power 100-240VAC, 45 to 60Hz or 11-30VDC optional Burden 40VA maximum Sealing...
  • Page 16: Diagram Of The Setup Menus

    12. DIAGRAM OF THE SETUP MENUS 12.1. Parameters 12.2. Meter calibration modes 12.3. DIRECT calibration – Full scale setting / Zero setting MA-DISP-FP4x & 6x_EN Page 16 on 18 Rev: 08/02/2012...
  • Page 17: Theoretical - Full Scale Setting / Zero Setting

    12.4. THEORETICAL – Full scale setting / Zero setting 12.5. Moving the decimal Only in an editable field (INP1, DSP1,…) 12.6. Tare Here‟s another way to tare. Just be sure that the lockout switch is ON. MA-DISP-FP4x & 6x_EN Page 17 on 18 Rev: 08/02/2012...
  • Page 18: Certificate Of Ce Conformity

    CERTIFICATE OF CE CONFORMITY 13. CERTIFICATE OF CE CONFORMITY We, SENSORS AND SYNERGY S. A., declare that the product called DISP-FPxx is manufactured by our ISO 9001 qualified supplier in conformance with the essential requirements of the CE-marking directive 93/68/EEC and carries the CE mark accordingly.

This manual is also suitable for:

Disp-fp4Disp-fp6

Table of Contents