Page 1
Dometic Corporation. Every precaution has been taken in the preparation of this manual to insure its accuracy. However, Dometic Corporation assumes no responsibility for errors and omission. Neither is any liability assumed for damages resulting from the use of this product and information contained...
NOTICE The largest unit that the CR330 should be used with is a 16,000 BTU air conditioner at 4.0 GPM (15.1 LPM). Use the CR330 only on a single pump to a single air conditioning unit installation. Do not use the CR330 on single pump to multiple unit installation.
Venturi effect, a separate condensate pump is not required. A water filter/strainer, a reducer and a check valve are also provided and must be installed with the CR330. The filter prevents debris from entering the CR330 and obstructing the water flow. The check valve allows the condensate to flow in only one direction.
Cut a 7 ft (210 cm) piece of the 1/4" tubing. Connect one end to the check valve and the other end to the CR330. Secure both connections with 1/4" stainless steel screw-type hose clamps.
Page 6
1/2" MPT x 1/4" hose barb Hold-down strap for CR330 1/4" stainless steel screw-type hose clamp 1/2" MPT fitting x 1/2" hose barb NOTE: Total length from A/C unit to CR330 must not exceed 10 ft (3 m). L-3359 ENGLISH...
Spray off the wire mesh with water or using a wire brush, gently remover debris form the screen. Reassemble the components. To clean the CR330: Should the CR330 become clogged, it can be cleaned with pressurized water. Alternately, a small probe, e.g., a paper clip, can be used to remove obstructions from the orifice. REPLACEMENT PARTS LIST Refer to Figure 1, page 4.
Page 8
DOMETIC MARINE DIVISION 2000 N. Andrews Ave. Pompano Beach, FL 33069 USA +1 954-973-2477 +1 954-979-4414 Email MarineSales@dometic.com 24/7 TECH SUPPORT FOR UNITED STATES AND CANADA 8:00 AM to 5:00 PM Eastern Time: +1 800-542-2477 After hours and weekends: +1 888-440-4494...