Advertisement

Operating Manual Program Timers Variotime Single and Variotime Twin
Operating Manual
Program Timers
Variotime Single
Variotime Twin
Fig. 1: Variotime Single, first from left with optional accessories mounted
Variotime Twin, first from right
Please note:
This operating manual is designated for use by our OEM customers and as
supporting material for their own appliance manuals.
Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen
Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •
info@diehl-controls.com
• www.diehl.com/controls/appliance
Subject to change without notice – issued 04-2015 – page 1/20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Program Timers and is the answer not in the manual?

Questions and answers

Summary of Contents for Diehl Program Timers

  • Page 1 This operating manual is designated for use by our OEM customers and as supporting material for their own appliance manuals. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 2: Table Of Contents

    Setting the switching points ................15 Reset function ....................17 Skip function ....................17 Technical Data .................... 19 Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance...
  • Page 3: General

    Variotime Single Variotime Twin Diehl AKO Stiftung & Co. KG, Appliance Europe, Pfannerstraße 75-83, DE-88239 Wangen Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...
  • Page 4: Functions Of The Program Timer Variotime

    • Up to 112 switchings per week by forming program blocks • Reset function • Skip function Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...
  • Page 5: Description Of The Functional Elements

    Fig. 4: Connections of Variotime Single with panel-mount housing (shown as ON/OFF version: changeover contact no. 4 not placed) Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...
  • Page 6: Functional Elements

    The day button may alternatively be denominated DAY. The hour and minute buttons h and m may alternatively be denominated HR and MIN. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 7: Variotime Single With 24 Hour Program

    (printed as OVER RIDE in this version only) Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance...
  • Page 8: Variotime Twin

    Skip button to immediately reverse ⑭ the present operating mode Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance Subject to change without notice – issued 04-2015 – page 8/20...
  • Page 9: Display Symbols

    ③ and ⑤ placed, a changeover version has the contacts ③, ④ and ⑤ placed. Please observe the product label on your timer. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 10: Variotime With Panel-Mount Housing

    2.4.2 Variotime with panel-mount housing Two each fixing brackets Diehl Controls material no. 413271110 (see Fig. 1) serve to easily mount the timer at the back of a panel. The notched dovetail-guides engaging into the sides of the timer housing allow secure mounting notwithstanding the panel thickness.
  • Page 11: Operating Variotime

    Set the present time of day via the buttons h and m (24 hour version: buttons plus or minus). Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 12: Channel Indication

    Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 13: Setting The Operating Modes

    Set the left-hand slide switch to position I. Press the skip button to select the desired channel: Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...
  • Page 14: Deactivation Mode

    Both channels deactivated Proceed as follows: Set the left-hand slide switch to position 0. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance...
  • Page 15: Automatic Mode

    The 112 switchings per week result from the possibility to assign identical switching points to several days of the week. Diehl Controls advises to set up a time schedule first as a basis to input a complex block program for several days. For setting, use the day button with the following combinations: •...
  • Page 16 (Variotime Twin: P1 or P2). Select the individual switching points by pressing the button repeatedly. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance...
  • Page 17: Reset Function

    It serves to override individual switching points without having to change the automatic program. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 •...
  • Page 18 Variotime reverts to the current operation mode according to its programming. Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com • www.diehl.com/controls/appliance...
  • Page 19: Technical Data

    Variotime with build-in housing: 62 x 62 x 30.5 mm Variotime with panel-mount housing: 72 x 72 mm Details see relevant timer drawing Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...
  • Page 20 Tab terminals 6.3 x 0.8 mm in compliance with EN 61210 Approvals VDE – ENEC and UL/CSA (technical conditions apply) Diehl AKO Stiftung & Co.KG, Appliance Europe, Pfannerstraße 75-83, DE – 88239 Wangen Tel. +49 (7522) 73-0 • Fax +49 (7522) 73-250 • info@diehl-controls.com •...