Download Print this page

PISCO VFL360-10-2-3 Quick Start Manual page 7

High flow vacuum filter

Advertisement

0.01
0.001
0.0001
How to remove the dust in bowl and replace a filter element
① Turn the bowl to the arrowed direction ( ① -2)
while pushing down the lock clip( ① -1).
Align the marking on lock clip to the one on body.
② Pull down the bowl to detach it from the body.
③ Turn the deflector to the arrowed direction to align its OPEN ▽ marking to △ marking on the bowl.
④ Detach the deflector from the bowl and take out the filter element from the bowl.
⑤ Take out the baffle from the filter element. (Only for replacement of filter element)
⑥ Remove dust from the bowl and replace the filter element.
⑦ Attach the baffle to the new filter element.
⑧ Place the filter element vertically in the bowl and confirm that the O-ring is on the right position. Attach the deflector to the
bowl with its OPEN ▽ marking aligned with △ marking on the bowl. Then turn the deflector to align its LOCK ▽ marking to △
marking on the bowl.
⑨ Insert the bowl to the body with the marking on the lock clip aligned with the marking on the body. Turn the bowl until the lock
clip goes up and lock with a click.
OPEN▽ marking
LOCK▽ marking
△ marking on bowl
VFL360-10-200M
VFL360-03-200M, VFL360-G3-200M, VFL360-12-200M
VFL360-04-200M, VFL360-G4-200M, VFL360-16-200M
VFL360-06-200M, VFL360-G6-200M
10
Marking on body
Deflector
Model code
VFLD360
Baffle
Model code
VFLS360
Element : 200µm
100
Flow rate ( ℓ/min [ ANR ] )
①-1
Bowl
Filter element
Model code
VFE360-1M
VFE360-5M
VFE360-10M
VFE360-200M
O-ring
Model code
60×2
http://www.pisco.com
1000
Bracket
Model code
VFLB360
* With 2pcs of fixing screw
Marking on lock clip
①-2
Lock clip
Filtration accuracy ( ㎛)
1
5
10
200
Proper position of O-ring