Shipping Inspection; Codes & Regulations; Features; Installation Clearances - Maytag Amana VZC20 Installation & Service Reference

Heat pump unit
Hide thumbs Also See for Amana VZC20:
Table of Contents

Advertisement

T
P
HE UNIT HAS ITS OWN
UMP
MODE WHILE VACUUMING THE UNIT
CAUSE INTERNAL ELECTRICAL ARCING
.
FAILED COMPRESSOR

SHIPPING INSPECTION

Always keep the unit upright; laying the unit on its side
or top may cause equipment damage. Shipping damage,
and subsequent investigation is the responsibility of
the carrier. Verify the model number, specifications,
electrical characteristics, and accessories are correct
prior to installation. The distributor or manufacturer will not
accept claims from dealers for transportation damage or
installation of incorrectly shipped units.
CODES & REGULATIONS
This product is designed and manufactured to comply
with national codes. Installation in accordance with such
codes and/or prevailing local codes/regulations is the
responsibility of the installer. The manufacturer assumes
no responsibility for equipment installed in violation of any
codes or regulations. Rated performance is achieved after
20 hours of operation. Rated performance is delivered at
the specified airflow. See outdoor unit specification sheet
for split system models or product specification sheet for
packaged and light commercial models. Specification
sheets can be found at www.goodmanmfg.com for
Goodman
brand products or www.amana-hac.com for
®
Amana
brand products. Within the website, please select
®
the residential or commercial products menu and then
select the submenu for the type of product to be installed,
such as air conditioners or heat pumps, to access a list
of product pages that each contain links to that model's
specification sheet.
The United States Environmental Protection Agency (EPA)
has issued various regulations regarding the introduction
and disposal of refrigerants. Failure to follow these
regulations may harm the environment and can lead to
the imposition of substantial fines. Should you have any
questions please contact the local office of the EPA.
If replacing a condensing unit, heat pump or air handler,
the system must be manufacturer approved and Air
Conditioning, Heating and Refrigeration Institute (AHRI)
matched.
NOTE: The installation of an inverter heat pump
with unmatched system units will not allow for
proper operation.
CAUTION
-
. U
P
DOWN MODE
SE THE
UMP
. V
ACUUMING TOO LOW CAN
,
RESULTING IN A DAMAGED OR
-
DOWN
Inverter Heat Pump models can only be matched with an
AVPEC air handler or TXV-V** expansion valve kit. Damage
resulting from operation with any other combination is not
covered by our warranties.
NOTE: For AVZC200241AF / 0361AE / 0481AE /
0601AE or older, please refer to IOA-4013F. This
manual is for AVZC200241AG / 0361AF / 0481AF
/ 0601BA or later and GVZC200241AA / 0361AA /
0481AA / 0601AA or later.
Outdoor inverter units are approved for operation above
0°F in cooling mode and -20°F (RH10%) in heating mode
with no additional kit necessary.
Damage resulting from operation of the units in a structure
that is not complete (either as port of new construction or
renovation) is not covered by our warranties.
This heat pump is part of a ComfortBridge™ control system
that uses inverter technology to more efficiently control
heat gain/loss with better efficiency and achieve targeted
comfort conditions.
The system utilizes digital communication between the
indoor and outdoor equipment and can be controlled by
any single-stage thermostat.
The ComfortBridge control system reduces the number
of required thermostat wires, provides additional setup
features and enhanced diagnostics through Bluetooth
connectivity with the CoolCloud™ app.
Due to components using inverter technology, the heat
pump will not function properly if used with a non-approved
control system.
Approved systems are combination of comfortbridge
compatible indoor unit and single-stage thermostat (with
dehumidification function). If do not use comfortbridge
compatible indoor unit, use CTK04AE or newer thermostat.

INSTALLATION CLEARANCES

Special consideration must be given to location of the heat
pump unit(s) in regard to structures, obstructions, other
units, and any/all other factors that may interfere with air
circulation. Where possible, the top of the unit should be
completely unobstructed; however, if vertical conditions
3
NOTICE

FEATURES

NOTICE