SPI Lasers redPOWER QUBE Instructions For Use Manual

SPI Lasers redPOWER QUBE Instructions For Use Manual

3kw – 8kw fiber lasers
Hide thumbs Also See for redPOWER QUBE:
Table of Contents

Advertisement

Quick Links

redPOWER QUBE
3kW – 8kW
Fiber Lasers
Instructions for Use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the redPOWER QUBE and is the answer not in the manual?

Questions and answers

Summary of Contents for SPI Lasers redPOWER QUBE

  • Page 1 QUBE 3kW – 8kW Fiber Lasers Instructions for Use...
  • Page 2 Laser Integrators are not authorised to modify this QUBE Fiber Laser. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 3 Instructions for Use ensure that power to the QUBE Fiber Laser is disconnected. Failure to do so may lead to serious personal injury. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 4 IEC/EN 60825-1. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 5: Table Of Contents

    Alarms and Warnings Basic Control using Serial Communication Maintenance Periodic Inspection General Cleaning Maintenance of Optics © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 6 Figure 12 Interface Connectors ....................... 41 Figure 13 Routing of AC Power Cable ....................43 © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 7 Table 5 Interface Connectors ........................41 Table 6 Electrical Supply Cable Wire Sizes .................... 42 © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 8 Table 25 Mechanical Specifications – PIPA-Q Optical Connector ............83 Table 26 Contact Information ........................85 © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 9: Structure And Scope Of Instructions For Use

    1 Structure and Scope of Instructions for Use These Instructions for Use for SPI Lasers’ redPOWER ® QUBE 3kW to 8kW Fiber Lasers contain all the information that Users need to know for their safe and efficient use. This information is important. These Instructions for Use must be read before installing and using the Laser and made available for reference at the location where the Laser is being used.
  • Page 10: Definition Of Symbols And Terms

    Cautions must be observed to prevent personal injury and damage to or destruction of equipment or loss of operational effectiveness. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 11 Those who have attended official Training Courses and have been Personnel: certified as competent. SPI Lasers: SPI Lasers UK Ltd. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 12: Health And Safety

    • carry out necessary inspection and maintenance work This Laser is not intended: © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 13: Hazards

    • for use in an explosion prone environment SPI Lasers cannot be held liable for any damage resulting from such use. The risk lies entirely with the User. Hazards Laser Hazards 3.3.1...
  • Page 14: Compliance

    Within the EU, the Laser is CE marked and is supplied with a Declaration of Conformity. The standards which SPI Lasers declares that the Laser is in conformity with, and the directives which SPI Lasers declares that the Laser complies with the requirements of are listed in the Declaration of Conformity.
  • Page 15 This Laser falls within the scope of the Low Voltage Directive as the Directive applies to electrical equipment designed for use with a voltage rating of greater than 75V. SPI Lasers has therefore demonstrated compliance to parts of the standards given below which are harmonised to the Low Voltage Directive: •...
  • Page 16: Labelling

    This Laser falls outside the scope of 21 CFR part 1040 as 21 CFR part 1040 does not apply to laser products which are sold to a manufacturer for use as components. However, SPI Lasers recognises that Laser Integrators may require the integrated laser system to comply with the regulation.
  • Page 17 Table 1 Labels Laser, Address, WEEE, CE and Patent label (rear panel) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 18 Laser hazard (optical connector) QUBE Fiber Laser identification (rear panel) Water Flow and Return Labels (rear panel) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 19: Document References

    4 Document References Document number Description redPOWER QUBE Cabinet Fiber Lasers Installation Drawing FS-S00154 redPOWER Fiber Laser Serial Communications Protocol SM-S00499 SM-S00537 FiberView and Machine Control Interface Instructions for use These documents may be downloaded by going to 'Customer Login' at the top right of SPI Lasers’...
  • Page 20: Redpower Qube Tour

    5 redPOWER QUBE Tour The range of redPOWER QUBE Cabinet Fiber Lasers builds on many years of experience of SPI Lasers in designing, developing and supplying fiber lasers into a wide range of industrial laser processing applications. It gives laser integrators the capability to manufacture industrial laser machines with maximum output power levels from 3kW to 8kW.
  • Page 21: Figure 2 Qube Fiber Laser Key Parts (Front)

    Figure 2 QUBE Fiber Laser Key Parts (Front) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 22: Figure 3 Qube Fiber Laser Key Parts (Rear)

    Figure 3 QUBE Fiber Laser Key Parts (Rear) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 23: Figure 4 Qube Fiber Laser Key Parts (Pipa-Q)

    Figure 4 QUBE Fiber Laser Key Parts (PIPA-Q) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 24: Key Features

    Fiber Laser is represented by the red rectangle and the cooling water circuits are indicated schematically in blue. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 25: Figure 6 Redpower Prism Fl Module Key Features

    Module is represented by the red rectangle and the cooling water circuit is indicated schematically in blue. o Optical Engine The heart of the PRISM FL Module is the optical engine based on SPI Lasers’ ® proprietary GTWave active fiber technology. GTWave takes the optical power of the pump diodes to generate the high beam quality output of the Laser.
  • Page 26 The FVCU allows the Laser to be controlled either by using the Laser Integrator’s interface or by using SPI Lasers’ FiberView software. The FVCU also takes the inputs from the sensors in the PRISM FL Modules, the pump diode PSU and the safety circuit and generates alarm and warning signals.
  • Page 27: Figure 7 Pipa-Q Optical Connector With Protection Against Back-Reflection

    In extreme cases, the Laser shuts itself down before damage occurs. The optical connector incorporates the SPI Lasers patented technology, which channels back-reflected power away from the delivery fiber via a capillary tube into a water cooled beam dump, as shown in Figure 7, preventing damage to the delivery fiber or its mechanical fixings.
  • Page 28 Indicator is flashing if there is an Alarm condition. The Laser will be in the OFF state. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 29: Fiberview Graphical User Interface

    The Air Conditioning Unit is a factory fitted option. FiberView Graphical User Interface SPI Lasers’ Graphical User Interface, FiberView, allows Users to control this Laser over a serial interface. Operation of the Laser using FiberView is described in SM-S00537, FiberView and Machine control Interface Instructions for Use.
  • Page 30: Control System Safety Functions

    FiberView. The functions are as follows. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 31 PSU and requires two volt free contacts connected to PL81. See Section 7.5.6 for more details. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 32 Prevention of unauthorised use Prevention of unexpected start-up PLd Emergency stop Remote interlock E-shutter FCMS © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 33: Auxiliary Equipment

    Auxiliary Equipment Figure 9 QUBE Fiber Laser with Auxiliary Equipment © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 34: Explanation Of Order Codes

    SPI Lasers does not assume responsibility for specific integration decisions affecting the safety and compliance to international standards of the Laser Integrator’s final laser product or system. Explanation of Order Codes The redPOWER QUBE Fiber Laser variants covered by these Instructions for Use have order codes: SP - 3000...
  • Page 35 Not all combinations of options are available. Further information can be provided by request from SPI Lasers. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 36: Getting Started

    Retain all packaging materials until the Laser has been commissioned. If anything is missing or defective contact SPI Lasers. See Section 14 for contact details. Unpacking the Beam Delivery Optic Take care not to twist the conduit when uncoiling the BDO.
  • Page 37: Installation

    © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 38: Cooling Water Connections

    The inlet and outlet water connections are SMC MS-5HLH-6 type miniature elbows suitable for 6mm LLDPE or polyurethane tubing. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 39: Figure 10 Hose For Main Connection

    The hoses should be pushed fully on to the connectors and secured with hose clips as shown in Figure 11. Figure 11 Hoses Connected and Secured For connection to the optical connector SPI Lasers recommends LLDPE or polyurethane tubing. John Guest and SMC part numbers are given in Table 4. Table 4 Water Tubing...
  • Page 40: Air Conditioning Unit

    All User connections are located inside the right door of the Laser as shown in Figure 12. The connections are described in more detail in Table 5. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 41: Figure 12 Interface Connectors

    6 way 5.08mm pitch Phoenix Contact part PL91 7.5.7 and Remote Reset connector number 1778027. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 42 The supply rating is given in Section 12.3.1. The Laser must be grounded and must have a neutral connection. The cable shall have copper conductors: SPI Lasers does not recommend using aluminium conductors with the terminals provided in the Laser.
  • Page 43: Figure 13 Routing Of Ac Power Cable

    Check the continuity of the earth/ground connection before switching on the supply. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 44 PC to the Laser a crossover (NULL MODEM) cable must be used. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 45: Table 8 Serial Port Connections

    Laser STANDBY Laser ON / Process Cycle Start Process Cycle Step Unconfigured Alarm Reset Unconfigured © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 46 5 seconds. Each time it operates the energy in the capacitors must be dissipated © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 47 © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 48 Figure 16 shows connections to a control contact and indicator lamps using the laser 24V DC. Figure 17 shows connections to a PLC using an external 24V DC supply. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 49 Figure 16 Typical Connections to PL82 (Control Contact and Indicator Lamps) © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 50 Set Laser ON • Laser process takes place • Clear Laser ON • Clear PSU Enable © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 51 The alarm can be reset by opening and closing the other channel. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 52 5mA.The interlock is not a high integrity safety function and must not be used to protect Users from laser radiation. Figure 20 shows a typical connection. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 53 It flashes for an alarm and is on continuously for a warning. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 54 24AWG to 12AWG, the strip length is 7mm or 0.25" and the tightening torque is 0.5-0.6Nm. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 55: Routing The Beam Delivery Optic

    Avoid shocks and impacts on optical connectors. • Avoid pulling, twisting and over-bending of the conduit. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 56 The BDO motion should be checked to ensure that the routing still complies with the points of good practice above. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 57: Connecting And Disconnecting The Pipa-Q Optical Connector

    Position the process head so that the receiver for the optical connector is horizontal. Remove the sealing plug from the receiver. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 58 Section 9.3. Figure 24 Red Dots Aligned © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 59 Remove the PIPA-Q optical connector from the receiver using the 2-step process. Unlocking Step 1: Pull the locking sleeve out by 2mm. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 60 Immediately after the optical connector is removed the protective cap must be refitted. The process head receiver should also be plugged to prevent dust entry. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 61: Operating Instructions

    • The contents of these Instructions for Use, and therefore the safety provisions in it. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 62: Powering The Qube Fiber Laser On And Off

    8.3.1 When the system detects an alarm condition, the Laser goes to the OFF state. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 63: Basic Control Using Serial Communication

    Refer to SM-S00499, Fiber Laser Serial Communications Protocol, for the exact structure and implementation of the above serial protocol commands. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 64: Maintenance

    Occasionally, the outside of the Laser may require cleaning to assure full and clear visibility of the warning labels. Before cleaning disconnect the Laser from the power supplies. Clean only with a clean damp cloth and if any labels become displaced contact SPI Lasers immediately for replacements.
  • Page 65: Maintenance Of Optics

    If the window on the optical connector is damaged, or too dirty to clean, a replacement window kit and window is available to order from SPI Lasers. The kit contains a replacement window assembly and the tools necessary to change it. Note that the window assembly is a consumable item and is not covered by the laser warranty.
  • Page 66 If this is unsuccessful then the window will need to be replaced as described in Section 9.3.3. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 67 Drip a single drop of isopropyl alcohol on the lens paper above the window. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 68 Secure the PIPA-Q optical connector horizontally to reduce the risk of dust settling on the internal surfaces. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 69 5. Gently tighten the window assembly using the PIPA-Q Window Assembly Spanner. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 70: Transport

    (Figure 3). • Route the tubing to a suitable drain or container. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 71: Packing And Moving

    If it is to be moved further use a forklift or pallet truck. If it to be transported to another site or returned to SPI Lasers Pack the Laser in the original packaging and include all original accessories and documentation as detailed in the original inventory.
  • Page 72: Disposal

    WEEE Directive on waste electrical and electronic equipment (WEEE) for a product of its class. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 73: Specifications

    30°C and the relative humidity is 80% then the cooling water temperature should be above 26°C to prevent condensation. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 74: Non-Operating Conditions

    Humidity (Storage and Transport) % RH Below 2°C the cooling circuit must be drained to prevent freezing © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 75: Utility Requirements

    PIPA-Q optical connector are given in Table 17 and Table 19. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 76: Table 16 Cooling Water Requirements

    The flow rate must be increased to compensate. Refer to the manufacturers’ instructions and safety information for the use of additives. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 77: Table 17 Cooling Requirements (Cabinet)

    Figure 34. Figure 34 Minimum Flow Rate against Inlet Water Temperature © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 78: Optical Specifications

    Wavelength Alignment Laser Maximum Output Power For stable operation at percentage of rated output power © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 79: Table 21 Multimode Optical Specifications: 50Μm Fiber

    10%-90% rated power, 20kHz modulation frequency, 50% duty cycle 90%-10% rated power, 20kHz modulation frequency, 50% duty cycle © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 80: Mechanical Specifications

    Mechanical Specifications 12.5.1 Overall Dimensions and Masses For detailed dimensions refer to FS-S00154, redPOWER QUBE Fiber Laser Installation Drawing. Simplified drawings giving the overall dimensions for the medium and tall cabinets are shown in Figure 35 to Figure 37 and the overall dimensions are given in Table 24.
  • Page 81 Figure 35 Small Cabinet: Overall Dimensions Figure 36 Large Cabinet: Overall Dimensions © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 82 Figure 37 Tall Cabinet: Overall Dimensions 12.5.2 PIPA-Q Optical Connector Figure 38 PIPA-Q Optical Connector © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 83: Table 25 Mechanical Specifications - Pipa-Q Optical Connector

    The contacts must not be connected to ground. © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 84: General Information

    The SPI Lasers logo, SPI, GTWave, redPOWER and redENERGY are trademarks (registered or applied for) of SPI Lasers in at least one of the United States of America, the United Kingdom, the European Community and China, and in various other territories throughout the world.
  • Page 85: Contact Information

    Or contact your local distributor. Tel: +44 (0)1489 779696 - Option 2 Contact your local office number © 2018 SPI Lasers UK Ltd. SM-S00521 Revision C 20 September 2018 redPOWER QUBE 3kW – 8kW Fiber Lasers Commercial in Confidence Instructions for Use...
  • Page 86: Customer Service

    Laser from the integrated laser system and make it safe and, if the Laser is to be returned to SPI Lasers, to ensure that all relevant return documentation is in place before shipment. Details of documentation requirements and copies can be obtained where required from SPI Lasers.

Table of Contents