PolyGard 2 / µGard 2 Sensors for Toxic Gases Sensor Cartridge for Toxic Gases (and Oxygen) Series: SC2 and MC2 Series User Manual August 2020 Up-to-date data sheets and user manuals can be found in the download area of www.msr-24.com. ...
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 3 Intended Use The PolyGard 2 sensors (SC2) are designed for the measurement of toxic gases and oxygen in a wide range of applications only in connection with a basic unit, e.g. SB2, MSC2, MSB2 and WSB2 of the PolyGard series.
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 4 2 Installation Electronics can be destroyed by electrostatic discharge (ESD). Therefore the installation work should be done only by persons connected to ground, e. g. by standing on a conductive floor or by taking appropriate grounding measures (acc.
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 5 3 Electrical Connection 3.1 Plug Connection (SC2) in SB2, MSB2, MSC2, WSB2 SC2 sensors are equipped with a reverse polarity protected connector (3-pin). It must not be plugged in the wrong position by force (already clamped at the factory).
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 6 5 Calibration The service tool STL06 or PCE06 Software are available for convenient on-site calibration. See description of Service Tool STL06 or PCE06 Software. There is also the possibility to exchange the SC against a calibrated SC on site. The used SC can then be calibrated directly in the office or at the MSR_E Calibration Service and then reused again.
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 7 Zero calibration • Apply synthetic air (flow rate according to the table "calibration", 1 bar ± 10%) to the Sensor Cartridge. • The current zero offset and the offset value of the first calibration is read by displaying. •...
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 8 Apply a defined gas concentration on the sensor element with the help of the gas generator and check the measurement signal at the analog output or at the relay outputs. With this test, the complete function chain “Sensor Element >...
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 9 7 Troubleshooting Indicators at the SC2 The SC2 has got no diagnostic indications; they are only available on the PCB of SB2, MSC2, MSB2 or WSB2. Indicators at the MC2 The 4–20 mA output of the MC2 can be used as diagnostic indicators.
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 10 8 Cross-sensitivity Data The cross sensitivity depends on the used transmitter type and can be read from the table Technical Data (see section 9.3). Other gases can have an influence on the sensitivity, too. The table does not claim to be complete.
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 11 Sensor Cartridge (SC2) ELECTRICAL Power supply 5 V DC from Sensor Board (e.g. SB2/MSB2), reverse polarity protected Power consumption: 10 mA, max. (0.05 VA) Serial interface local bus 1-wire / 19200 Baud SENSOR ELEMENT Gas type...
® ® User Manual - PolyGard 2 / µGard Sensors for Toxic Gases Page 15 11 Part Disposal Since August 2005 there are EC-wide directives defined in the EC Directive 2002/96/EC and in national codes concerning the waste electrical and electronic equipment and also regarding this device. For private households there are special collecting and recycling possibilities.