Download Print this page

Advertisement

Quick Links

IRON RANGE FLOOR MODEL GAS FRYERS
GAS FRYER MANUAL
Owner's Manual – Installation Guide
Models covered in this manual are:
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance instructions thoroughly before installing or
For Warranty Service Call 866-359-7378
IRF-40NAT, IRF-40LPG
IRF-50NAT, IRF-50LPG
IRF-75NAT, IRF-75LPG
servicing this equipment.
OWNER'S/INSTALLER MANUAL
Revision IR20191009
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the IRF-40NAT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IRON IRF-40NAT

  • Page 1 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS GAS FRYER MANUAL Owner’s Manual – Installation Guide Models covered in this manual are: IRF-40NAT, IRF-40LPG IRF-50NAT, IRF-50LPG IRF-75NAT, IRF-75LPG Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
  • Page 2 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS To ensure proper warranty, record your information here: Date of Purchased: _________________________________ Dealer Purchase from: _________________________________ Name of Installer:________________________Phone Number:__________________________ Model Number: _________________________________ Serial Number: ______________________________________ For Warranty Service please call 866-359-7378 For Technical Support: 800-228-7253 or email: techsupport@ironrange.co...
  • Page 3 In the event a gas odor is detected, shut down equipment at the combination gas valve and contact local gas company or gas supplier. IRON RANGE Gas Floor Model Fryers are intended for commercial use only. Not for household or residential use.
  • Page 4: Table Of Contents

    Congratulations! You have purchased one of the finest pieces of commercial cooking equipment on the market. You will find that your new equipment, like all IRON RANGE equipment, has been designed and manufactured to meet the toughest standards in the industry. Each piece of IRON RANGE equipment is carefully engineered, and designs are verified through laboratory tests and field installations.
  • Page 5: Gas Supply And Burner Information

    OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS Supply pressure should be a minimum of 6” Water Column for Natural Gas and 12” Water Column for Propane. The fryer comes with ¾” NPT male connector on a ½” pipe, allowing you to connect with either a ¾”...
  • Page 6 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS Step #2: Install the Casters and Restraints A set of casters is packed with the fryer. Mounting fasteners are pre-mounted on the base plates. (Legs, not supplied, can be added as an optional accessory) 1.
  • Page 7 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS Step #3: Flue Installation 1. Unpack the flue box and flue wrap 2. Slide the flue box over the flue and secure it with the two self-tapping screws using a 5/16” socket 3.
  • Page 8 Six (6) Inches Rear: Six (6) Inches ALL IRON RANGE FRYERS SHALL BE INSTALLED WITH AT LEAST A 16 INCH SPACE BETWEEN THE FRYER AND SURFACE FLAMES FROM ADJACENT EQUIPMENT. A FLAME GUARD IS ACCEPTABLE IF ALLOWED UNDER LOCAL CODE.
  • Page 9 (natural gas or propane). The fryer should be connected ONLY to the type of gas for which it is equipped. A circuit diagram is located inside the front door of the fryer. All IRON RANGE equipment is adjusted at the factory; however, pilot height should be checked at installation and adjusted, if necessary.
  • Page 10 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS Step #5: Gas Connection (Continued) Connect the gas supply directly to the 3/4" male NPT connector located near the lower left rear corner of the fryer. When tightening the supply pipe, be sure to hold the mating connector extending from the unit securely with a wrench.
  • Page 11: Operation

    OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS PERATION NEVER ATTEMPT TO MELT A SOLID BLOCK OF SHORTENING ON TOP OF THE HEAT TUBES. NEVER START THE BURNERS WHEN THE FRYPOT IS EMPTY. THIS WILL CAUSE CRACKED SEAM WELDS AND YOUR FRYER WILL LEAK COOKING OIL, THIS IS AN UNSAFE CONDITION FILLING THE FRYPOT 1.
  • Page 12 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS IF YOU SMELL GAS DURING THE LIGHTING PROCEDURE, IMMEDIATELY SHUT OFF THE GAS SUPPLY UNTIL THE LEAK HAS BEEN CORRECTED! Lighting the Pilot Open the burner compartment door and do the following: 1.
  • Page 13: Cooking Hints

    HIGH LIMIT CONTROL IRON RANGE Fryers are equipped with a secondary heat control that prevents the oil temperature from rising above 450°F. (Because of the accuracy tolerance of the sensor, the oil temperature may reach as high as 475°F.)
  • Page 14: Cleaning

    IRON RANGE FLOOR MODEL GAS FRYERS LEANING IRON RANGE equipment is constructed with the best quality materials and is designed to provide durable service when properly maintained. To expect the best performance, your equipment must be maintained in good condition and cleaned daily. Naturally, the frequency and extent of cleaning depends on the amount and degree of usage.
  • Page 15 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS MONTHLY CLEANING 1. Perform the Weekly Cleaning procedure (see previous section). 2. Clean around burner and orifices if lint has accumulated. 3. Visually check that burner carry-over ports are unobstructed. CLEANING STAINLESS STEEL SURFACES To remove normal dirt, grease and product residue from stainless steel use ordinary soap and water (with or without detergent) applied with a sponge or cloth.
  • Page 16: Parts

    OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS ARTS Installation of other then genuine IRON RANGE parts will void the warranty on this equipment. The serial plate is located inside the front door on the left side. Replacement parts may be ordered through an IRON RANGE Authorized Parts Distributor. When ordering parts, please have the Model Number and Serial Number of your fryer, Part Number and Description.
  • Page 17 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS ARTS CONTINUED Part # Description Tube Tube Tube 400037 Basket Support 400056 Basket Support 400036 Drain Valve, (Ball Style) C200016 Fry Tank Only C200017 Fry Tank Only C200056 Fry Tank Only 400071...
  • Page 18 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS Part # Description Tube Tube Tube 100106 Door Assembly Complete 100137 Door Assembly Complete 300032 Door Magnet 6” Adjustable Leg 400147 266001-1 Caster Kit, (2 Front Swivel w/Brake, 2 Rear Fixed) Fry Basket (13.25” L x 6.5” W x 6” D) 400057 Fry Basket (17.5”...
  • Page 19 OWNER’S/INSTALLER MANUAL IRON RANGE FLOOR MODEL GAS FRYERS (THIS PAGE LEFT INTENTIONALLY BLANK) For Warranty Service Call 866-359-7378 Revision IR20191009 Page 19...
  • Page 20 We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact an IRON RANGE Authorized Service Provider, or your equipment dealer. To avoid confusion, always refer to the model number, serial number and the gas type of your unit.

This manual is also suitable for:

Irf-40lpgIrf-50natIrf-50lpgIrf-75natIrf-75lpg