Universal UTC-3306 Installation Manual

Barrier operator

Advertisement

Quick Links

Barrier Operator UTC-3306
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UTC-3306 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Universal UTC-3306

  • Page 1 Barrier Operator UTC-3306 Installation Manual...
  • Page 2: Technical Specifications

    Never open the door or the cover of the cabinet when the machine is running.  Do not permit children to play on or around the gate. Technical Specifications DC Series - UTC-3306 Power Supply: 120V 60Hz Motor’s Power: 80W / 24V DC Motor’s Rotation: 1400r/min...
  • Page 3: Installation And Adjustments

    Installation and Adjustments 1) Installing the barrier on the ground: 2) Installing the boom (Fig. 2) 3) Adjust the limit position. The barrier is supplied with the magnet limit switch and the mechanical limit switch for optimum boom movement. Do not chance the limit position.
  • Page 4 Boom Length 1) Adjust the vertical and horizontal line of the boom. If the boom needs to be shorter. The boom may slope upwards after becoming shorter. The strength of the spring may have to be decreased, refer to appendix. Manually put up the boom perpendicularly.
  • Page 5 Boom Length (Continued) 2) If the boom needs to be longer. The boom may slope downward after becoming longer. The strength of the spring may have to be in- creased, refer to appendix. Manually put up the boom perpendicularly. 1) Loosen the adjusting nuts. 2) Adjust the tuning screw and check the boom.
  • Page 6: Electrical Safety Devices

    Spring Ratio Per Boom Length 3-4m 5x440mm 4.5m 6x440mm UTC-3306 5x440mm 5x440mm Electrical Safety Devices 1) The barrier’s limit switches, motor, and control unit are already connected. 2) One the photo cells, loop detector, and the supply voltage have not been connected.
  • Page 7 Control Box (DC Motor) Technical Data Power Supply AC 120V 60Hz Max. Consumption 120W Accessories Power Supply 24V DC 10W Max Environment Temperature -20C ~ +5-C Frequency of Remote Control 433.92 MHz Auto-close Delay Time 1 –120 seconds Wiring Diagram (DC Motor) F1: 8A Fuse VR1: Potentiometer of pause time...
  • Page 8: Dip Switch Setup

    Dip Switch Setup Dip1: ON: Enable auto close. The pausing time is adjustable when rotating the VR2 OFF: Disable auto-close Dip2: ON: The light flashes off when the boom stops. OFF: The light flashes on when the boom stops. LED Definitions Name Definitions Opening limit switch LED.
  • Page 9 Safety Device Wiring (Sold Separately) Photocell (N.C.) If the infrared ray is shut off when the gate is closing,  the gate opens instantly. If the infrared ray is shut off when the gate is open-  ing, the gate remains open. Loop Detector (N.C.) If a car is in range of loop while gate is closing, the ...
  • Page 10 Wiring (Continued) Dip1 should be Off Loop Detector (N.O.) If a car is in range of the sensor, the gate remains  open. When a car passes through the range of the sensor,  the gate closes. External Terminal When a IC card reader is used, it must be connected with OPN and GND ...