Download Print this page

Kohler K-1112P-GLF Roughing-In Manual page 2

Bath with airjets canada

Advertisement

Available languages

Available languages

No change in measurements if connected
with drain illustrated. (K-11677 or K-11677M)
Recommended faucet area
1-1/4"
(3.2 cm)
Tile Flange
Detail
42" (106.7 cm)
1-1/2" OD
Product Information
Applicable product:
Drop-in, 3-side integral flange, left drain
Drop-in, 3-side integral flange, right drain
Fixture*:
Bathing well
Basin area
43" (109.2 cm) x 20-1/2" (52.1 cm)
bottom
Basin area top
53-1/2" (135.9 cm) x 32-1/8" (81.6 cm)
Weight
110 lbs (50 kg)
To overflow
Water depth
15" (38.1 cm)
Capacity
57 gal (215.9 L)
* Approximate measurements for comparison only.
Drop-in cutout dimensions:
58-1/2" (148.6 cm) x 40-1/2" (102.9 cm)
Blower motor:
Heater
300 W
Minimum access panel pump/control:
20" (50.8 cm) W x 15" (38.1 cm) H
1076050-1-C
1-1/2"
(3.8 cm)
Drop-In Rim
Detail
Blower/Control Access
20" (50.8 cm) W x
15" (38.1 cm) H Min
1-1/4" (3.2 cm)
19-1/2"
21"
(49.5 cm)
(53.3 cm)
K-1112P-GLF
K-1112P-GRF
V
Hz
120
60
required
60" (152.4 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Blower motor is supplied with a 24" (61 cm) grounding-type
plug-in cord.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
36 lbs/square foot (174 kg/square meter) loading.
If installing a rim-mount faucet, make sure there is no interference
with the drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
The hot water supply should be 70% of the capacity of the bath or
greater. Installations will vary.
This fixture conforms to CSA B45 and ANSI Standard Z124.1.2. All
dimensions are nominal.
A
5
2
21" (53.3 cm)
3-1/8" (7.9 cm)
10-13/16"
(27.5 cm)
1-1/4" (3.2 cm)
3-1/2" (8.9 cm)
1" (2.5 cm) from the
Floor to the Bottom
of the Drain
120 V, 5 A, 60 Hz
Kohler Co.