Elcontrol VIP CLAMP MINI Series User Manual

Multimeter clamp

Advertisement

Quick Links

V
V
I
I
English
P
P
C
C
USER MANUAL
L
L
A
A
MINI” series multimeter clamp
M
M
read
respect
P
P
M
M
I
I
N
N
I
I
PRECAUTIONS FOR USE
Via Vizzano,44 - 40037 Pontecchio Marconi (Bologna) Italy
Tel.+39 0516782006 – Fax +39 051845544
......................................................................................
http://www.elcontrol-energy.net
e-mail (Comm.le Italia) vendite@elcontrol-energy.net
e-mail (Sales Dept.)
“VIP CLAMP
sales@elcontrol-energy.net

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIP CLAMP MINI Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Elcontrol VIP CLAMP MINI Series

  • Page 1 Via Vizzano,44 - 40037 Pontecchio Marconi (Bologna) Italy Tel.+39 0516782006 – Fax +39 051845544 ..................http://www.elcontrol-energy.net e-mail (Comm.le Italia) vendite@elcontrol-energy.net e-mail (Sales Dept.) sales@elcontrol-energy.net English USER MANUAL “VIP CLAMP MINI” series multimeter clamp read respect PRECAUTIONS FOR USE...
  • Page 2: Table Of Contents

    SOMMARIO 1.PRESENTATION... 2. DESCRIPTION 3. IMLEMENTATION-FUNCTIONAL CHARACTERISTICS.. 4. GENERAL SPECIFICATIONS 5. GUARANTEE MAINTENANCE 7. APPENDIX...
  • Page 3: I I

    1. PRESENTATION VIP CLAMP MINI 2. DESCRIPTION (vedi schema § 8 Allegato) Jaws 6-way rotary switch: var W~ Command keys Short pressure Long pressure Held pressure · HOLD · The yellow key has 6 different functions (see also description § 3.12): ·...
  • Page 4 Note: - Hz Short pressure: Held pressure: HOLD key/ switch combination Yellow key/ switch combination MIN/MAX key/ switch combination (see description § 3.12): -Date of last calibration performed on unit Liquid crystal display Digital display + OL - OL: Symbol display Flashing Steady Fixed:...
  • Page 5 The Buzzer - Short and medium sound: - Short and high-pitched sound: - Short and low sound: - 2 short and high-pitched beeps: - Short and medium sound every 400 ms: - 5 short and medium recurring beeps: - Short and medium sound: - Modulated medium continuous sound: 3.
  • Page 6 § Cable resistance compensation ( zero) Press and hold the HOLD key Note: If the value measured is higher than 2 W, this correction is stopped and the memorised correction value is reset to zero. Display range 400 W Measuring range Accuracy (1) Resolution Open circuit voltage...
  • Page 7: Description

    MIN/ MAX Mode: 3.6 Current measurements "A " Correction of the current measurement zero (DC zero) Note: Characteristics (1) In DC, the display indicates +OL above +400 A and -OL above -400 A (600 A in PEAK mode). In AC, the display indicates OL over 400 Arms (900 V in PEAK mode). (2) In AC, if the value of the current measured is <...
  • Page 8 Characteristics ³ 3.8 Power measurement (W var VA) SINGLE PHASE SYSTEM BALANCED 3 PHASES SYSTEM Nota : Specific reference conditions ³ ³ Active power measurement characteristics 4000W Display range 400 kW Measuring range(2) Accuracy (3) Resolution Reactive power measurement characteristics 4000W Display range 400 kW...
  • Page 9 MIN/ MAX Mode: 3.9 Power factor calculation (PF) Characteristics 1,00 Display range Measuring range(1) Accuracy Resolution - - - - MIN/ MAX Mode: 3.10 Frequency Measurement (Hz) Characteristics Display range 40 Hz 4000 Hz 400 Hz 40kHz Measuring range(1) Accuracy Resolution Triggering threshold (2) (2) Below the triggering threshold, the display shows an indeterminate value (- - - -...
  • Page 10 - Special reference condition Characteristics Running of phase rotation direction detection sequence Note 1: In the following table, display of the symbol refers systematically to the beginning of sequence Note 2: The sequence of the following table is described using: - L1 on terminal “COM”...
  • Page 11 3.12.3 Automatic compensation for cable resistance 3.12.4 Automatic compensation of current measurement zero 3.12.5 Manual selection of AC, DC or AC+DC mode 3.12.6 3.12.6 Selections possible in continuity function 3.12.7 Selection OF INRUSH function 3.12.8 Suppression of automatic stop 3.12.9 Activation of the V-Live function 3.12.10 Modification of audio indication threshold in continuity test 3.12.11 Default configuration of the unit 3.12.12 Date of last calibration carried out on unit...
  • Page 12: General Specifications

    3.12.13 Display of the internal software version HOLD 3.12.14 Showing of display segments 4. GENERAL SPECIFICATIONS 4.1 Dimensions and weight 4.2 Clamp Tightening Capacity < 4.3 Power Supply 4.4 Environmental parameters Temperature in °C Altitude < < Indoor use 4.5 Compliance with norms Electrical safety: secondo EN 61010-1, ed.
  • Page 13 4.6 Variations in operating range...
  • Page 14: Guarantee

    Tipica frequency responce curve 4.7 Marginal operating conditions 5. GUARANTEE 6. MAINTENANCE 6.1 Changing the battery 6.2 Storage 6.3 Cleaning Repair...
  • Page 15: Appendix

    APPENDIX APPENDIX...