POST MOUNT
1
Install the posts.
2
Install the electrical conduit.
3
Remove the bolts (4) and the top plate from the mounting stand.
4
Position the top plate over the square posts. The top plate must be level.
5
Fasten the top plate to the posts by welding completely around the posts.
6
Fasten the operator to the top plate with appropriate hardware.
CONCRETE PAD MOUNT
1
Lay out the concrete pad.
2
Install the electrical conduit.
3
Pour a concrete pad (reinforced concrete is recommended). The concrete pad should
be 6 inches above the ground and deeper than the frost line.
4
Attach the mounting stand to the concrete pad with appropriate hardware.
5
Attach the operator to the mounting stand with appropriate hardware.
01-35732
3
5
©2009 The Chamberlain Group, Inc. - All Rights Reserved
4
1
2
5
3
2
6" Above Ground
Below the frost line.
Check all local codes.
1
24"
(61 cm)
6
4
4 Concrete Anchors
1/2" x 3 1/2"
24"
(61 cm)