COD100B/SD102P
Carbon Monoxide and Smoke
Alarm Set
A home safety alarm set consisting of one SD102P photoelectric smoke detector with hush button and one
COD100B carbon monoxide detector. An essential kit for any home, these life saving devices alert the user
to the presence of deadly carbon monoxide gas or smoke from a potential fire.
COD100B Product Specifications:
Apparatus
Batteries
Alarm level
Sensor
Static working current
Operating temperature
Storage temperature
Humidity
Lifetime
Dimensions
Weight
Product layout:
Type B
3 x AA (supplied)
85dB @ 1m
Electromechanical
80uA
0°C to 45°C
-20ºC to 50ºC
0 to 90% RH
7 years from first use
120 x 87 x 40mm
220g (incl. batteries)
Item ref: 350.137UK
User Manual
1.
Power LED indicator
2.
Fault LED indicator
3.
Alarm LED indicator
4.
LCD display
5.
Alarm output
6.
Test/Menu button
7.
Back cover catch
8.
Battery compartment

Advertisement

loading
Need help?

Need help?

Do you have a question about the SD102P and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercury SD102P

  • Page 1 Carbon Monoxide and Smoke Alarm Set A home safety alarm set consisting of one SD102P photoelectric smoke detector with hush button and one COD100B carbon monoxide detector. An essential kit for any home, these life saving devices alert the user to the presence of deadly carbon monoxide gas or smoke from a potential fire.
  • Page 2: Installation

    Installation: Start up: Remove the alarm from the packaging and slide the back cover downwards to reveal the battery compartment. Insert 3 x AA batteries (supplied) to the correct polarity, the alarm will beep once and all 3 LEDs will flash to indicate power up. When the LCD display on the front starts to display information, the alarm is successfully powered and has start working.
  • Page 3: Operation

    Installation: After finding an appropriate location, the wall bracket can be screwed onto the wall using the supplied hardware. Alternatively it can be stuck on using a pad sticker or just rested on top of a unit. To mount the bracket using hardware, use the mounting plate as a guide to mark the two holes. Drill these holes 6mmØ, 30mm deep.
  • Page 4 The error can be caused by either loose connections on the circuitry, short circuit or sensor contaminated by other strong chemical fumes. Please leave the alarm in clean open air for 24hr and see if error disappears. If the error remains, please replace alarm immediately to remain protected from carbon monoxide.
  • Page 5: Maintenance

    again or wait and the average reading will show. The “PPM” will flash on the average reading display to differentiate it from the peak reading. The following menu option allows you to clear the record. When “clr” appears on the screen, simply press and hold the TEST button until “P--”...
  • Page 6 DO NOT re-enter the premises or move away from the door/window until the alarm has stopped. Call the UK Emergency Gas Services: 0800 111 999 Seek medical help immediately for those suffering with CO poisoning. DO NOT use appliances again until they have been checked by a qualified technician and the fault clearly identified and rectified.
  • Page 7 SD102P Specification: Battery 1 x 9V PP3 (supplied) Alarm output 85dB/3m Operation temperature -10°C ~+40°C Quiescent current ≤12µA Dimensions 34 x 101mmØ Weight 136g (with battery) Installation: Choose an appropriate position to install the alarm on a ceiling away from obstructions.
  • Page 8 Depress the test/hush button to check the alarm and warning LED are functioning correctly. The LED will also flash every 40 seconds to inform you the unit is working properly. Please note:  No user serviceable parts inside. The only replaceable part is the battery. ...