Acer Aspire 3630 Service Manual page 34

Hide thumbs Also See for Aspire 3630:
Table of Contents

Advertisement

LCD 15.0"
Item
Temperature Range( C)
Operating
Storage (shipping)
AC Adapter
Item
Vendor & model name
Input Requirements
Maximum input current (A,
@90Vac, full load)
Nominal frequency (Hz)
Frequency variation range (Hz)
Input voltage range (Vrms)
Inrush current
Efficiency
Output Ratings (CV mode)
DC output voltage
Noise + Ripple
Load
Output Ratings (CC mode)
DC output voltage
Constant current mode
Dynamic Output Characteristics
Turn-on delay time
Hold up time
Over Voltage Protection (OVP)
Short circuit protection
Electrostatic discharge (ESD)
Dielectric Withstand Voltage
Primary to secondary
Leakage current
Regulatory Requirements
Chapter 1
Specification
°
0 to 50
-20 to 60
LITE-ON - 65W, PA-1650-02 QY
1.5 A @ 110Vac
1.0 A @ 240Vac
50-60
47-63
90-265
Shall not be less than 220Amps (cold start) when AC input is 100V 60Hz and
DC output is +19V 3.42A
Shall not be less than 220Amps (cold start) when AC input is 240V 50Hz and
DC output is +19V 3.42A
It should provide an efficiency of 85% (typ. 88%) minimum, when measured at
maximum nominal voltage at 19.0V
19V
380mV
Voltage Nom. (V)
25.0
19V +/-0.95 for CV mode
3.6 +0.60A/-0.3A
5 sec (@ 115Vac)
5ms (@115Vac, Full load)
29V
5.0A max can be protected and output can be shorted without damage
+/-15KV (at air discharge)
+/-8KV (at contact discharge)
2150Vac
100uA
Safety Requirements:
1.The power supply must comply with the following national standards: UL,
CSA, CCC, BSM, PCBC< CE, FIMKO, DEMKO, NEMKO, SIMKO, TUV
2. Dielectric Strength-primary to secondary: 2150 VDC for 1sec.
3. Insulation Resistance- primary to secondary: 30 Meg. ohms Min., 500VDC
4. Ground Leakage Current- the power supply ground leakage current shall be
less than 100uA.
0 to 50
-20 to 60
Specification
Capacitance Nom.
Material Type
10/1.0
TAN/CERAMIC
0 to 50
-25 to 60
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents