DIMMING CONNECTIONS
RUNNING PARALLEL WITH 0/1-10V POT DIMMER
Please note: Do not connect anything
other than a 0/1-10V dimmer or control
system or the warranty will be void.
1.
Open the back of the light fitting.
2.
Safely locate the purple (+) and grey
(-) dimming cables, remove their
existing closed end connectors and
connect your 0/1-10V pot dimmer
(refer to diagram on the left). Re-
connect all grey and purple wires by
using a new end connector.
3.
Ensure you use suitable sealant/
glands to keep the IP rating.
4.
Refit the driver box back onto the
fitting, ensuring all seals are secure.
Water penetration from a failure to
seal the fitting properly will not be
covered under warranty.
5.
Set your desired max power output
with the DIP switch (referring to the
switch diagram located on the top of
the fitting)
RUNNING WITHOUT DIP SWITCH WITH 0/1-10V POT DIMMER
Please note: Do not connect anything
other than a 0/1-10V dimmer or control
system or the warranty will be void.
1.
Open the back of the light fitting.
2.
Safely locate the purple (+) and grey
(-) dimming cables, remove their
existing closed end connectors and
disconnect the purple and grey wires
of the DIP switch and cap each wire
off with an end connector. Connect
your 0/1-10V pot dimmer (refer to
diagram on the left) and re-connect
all grey and purple wires (sans the DIP
switch) by using a new end connector.
3.
Ensure you use suitable sealant/
glands to keep the IP rating.
4.
Refit the back plate and ensure all
seals are secure. Water penetration
from a failure to seal the fitting
properly will not be covered under
warranty.
T. 1300 222 445 | www.melec.com.au