Download Print this page

Sealey SM48.V3 Instructions page 2

Dust & chip extractor

Advertisement

2. APPLICATION & SPECIFICATION
the sM48.V3 is designed to extract dust, saw dust and other fine debris from wood machining. It should not be used to extract metallic
debris, glass or water.
Specification:
capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700cfm
Impeller diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228mm
Intake diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100mm
flexible hose diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100mm
flexible hose maximum length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5m
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V, 50Hz, 746W
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21kg
noise level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<87dBA
3. CONTENTS & ASSEMBLY
unpack the extractor components and check that all are present and undamaged. In case of shortage or damage please contact the supplier.
Description:
• Collector Body with Motor
• Base plate
• Castors x 4
• Inlet Hose (2.5m)
Note: Numbers in brackets are the item numbers on the parts diagram and in the parts list.
3.1.
Attach the four castors (1) to the underside of the base (4) using screws (2), washers (3) and nuts (2-1). support base (4) on
battens, or similar, raising castors clear of floor to give stability for the following assembly tasks.
note:
collector may be wall mounted using brackets (30) provided, which locate in holes (A) in base. If wall mounting do not fit castors.
3.2.
With screws (13) and washers (12) attach motor mount (20) to base plate (4).
3.3.
With screws (14), washers (12) and nuts (12-1) attach motor (18) to mount (20), so that collector body is positioned as shown in parts
diagram.
3.4.
Install outlet (23) to collector body (11) using packing (22), screws (15) and nuts (15-1).
3.5.
fit collector bag (24) over outlet (23) and secure with clamp (17).
3.6.
fit handle (25) to side of collector body (11) using screws (28).
4. OPERATING INSTRUCTIONS
 WARNING! before operating the extractor ensure that you read, understand and apply the safety instructions in Section 1.
Note: Numbers in brackets are the item numbers on the parts diagram and in the parts list.
4.1.
confirm that supply voltage matches the voltage shown on the motor data plate and that the motor switch (16) is 'off'.
4.2.
connect extractor hose (29) to the inlet (6) on the collector body (11) and attach other end to extractor point on equipment.
WARNING! DO NOT operate extractor without the hose attached.0
4.3.
Plug into mains supply and press motor switch 'on'.
4.4.
Ensure that the collector bag is emptied of dust and chips on a regular basis and is not allowed to become full.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
• Collector Bag
• Motor Mount
• Handle
• Wall Bracket x 2
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7Ar
Original Language Version
• Gasket
• Screws, nuts, washers (1 bag)
• Clamp
01284 757500
01284 703534
www.sealey.co.uk
Web
sales@sealey.co.uk
email
sM48.V3
Issue: 4 - 25/03/10

Advertisement