Please read this guide before installing, using the product, or performing any main- tenance operation. Failure to read, understand and follow herein instructions may result in personnal injury. In no event shall HIKOB be held liable for any damages arising out of or related to misunderstanding instructions detailed in this manual.
– IEC 60950-1:2005 + A1:2010 + A2:2013 – EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 The HIKOB AZURE LION is certified to follow the IEC 60 950-22 Am2 outdoor safety stan- dard. With exception for Finland, Norway and Sweden, countries where environment tem- perature can be far lower than the limit for operating and safety assurance temperatures the HIKOB AZURE LION.
HIKOB AZURE LION Version 2.0-2466 The HIKOB AZURE LION product is certified to be compliant with Japan Radio Law - Article 2 paragraph 1 Item 19. 1.3.3 USA Information to user This device complies with part 15 of the FCC Rules. Operation is sub-...
HIKOB AZURE LION Version 2.0-2466 RF Exposure This device complies with Industry Canada RF radiation exposure limits set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
2 General description of the HIKOB AZURE LION 2.1 HIKOB wireless sensor network acquisition system The HIKOB AZURE LION is one of the elements that constitutes the HIKOB wireless sensor radio network. This system is a set of wireless sensors doing multi-point distributed measures in various domains.These sensors radiotransmit their acquired data to the HIKOB GATEWAY,...
HIKOB AZURE LION Version 2.0-2466 rechargeable batteries. The HIKOB AZURE LION casing is water resistant with an IP67 pro- tection: it is suitable for outdoor installations. Should you decide to perform cleaning tasks on the HIKOB GATEWAY, don’t perform high pressure cleaning, prefer wiping with a dry cloth, or with a neutral agent.
100 and 300m to HIKOB GATEWAY or another router. 50m to sensor, 30m to a burried sensor Radio range given for a connection to a HIKOB WISE COW or HIKOB POLAR BEAR sensor, these sensor types are installed in road pavement, this alters radio transmission quality.
– The maximum distance between a HIKOB AZURE LION and a HIKOB GATEWAY, varies between 100 and 300m, depending on the terrain topology. – A HIKOB GATEWAY hosts 80 elements in all, and 30 as direct children in the multi hop radio network.
Page 11
/ gateway positions and orientations can be made empirically, by installing the system and running it for a trial fit. The HIKOB GATEWAY provides useful user information to appraise the radio signal quality between elements of the HIKOB network. Refer to section Radio quality link in the NET PULSE manual for that, reorient elements if needed, sometimes adding extra HIKOB AZURE LION enhances radio coverage.
For the best compromise, choose a good radio coverage rather than the best exposure for the solar pannel: the HIKOB AZURE LION is designed to run with 1 hour of sunshine a day, and is autonomous 2 mounths in total darkness.
So in that case, orient the antenna towards the ground, see figure. 4.2.2 Mounting procedure The HIKOB AZURE LION is delivered with all accessories needed for a good installation. This is a set of 3 elements: A clip coupled with a female thread screw. It hosts the mounting bracket of the HIKOB AZURE LION.
Page 14
HIKOB AZURE LION Version 2.0-2466 Figure 3: HIKOB AZURE LION installed on a pole. November 2015 Page 14/ 14...