Installation Instructions; Operation Guidelines - Lamppa KUUMA 100 Owners & Installation Manual

Vapor-fire non-catalytic
Table of Contents

Advertisement

1. Read thoroughly all of the installation and op-
eration instructions before attempting instal-
lation.
2. If your stove doesn't have any bricks, install
the bricks as shown in figure 34 page 5 (also
see figure 19, page 12).
3. The unit must be set on a non-combustible
surface, such as brick, ceramic tile, stone, or
concrete and be at least 1 inch in thickness
and 18 inches larger than the dimensions of
the base as stated in the specifications, fig-
ure 1. The non-combustible floor protection
must extend at least 16 inches in front of
the unit.
4. Install the blower assembly to the back of the
unit as shown in figure 16. See figure 3 for
STARTING A FIRE IN A COLD FIRE CHAMBER WITHOUT ANY HOT COALS
1. Open fire door.
2. Scrape the ashes through the grate.
3. Place a moderate amount of paper and kin-
dling on the FRONT half of the fire chamber
floor.
4. Place your logs on top of the paper and kin-
dling, making sure that front face of the logs
are kept 1 inch away from the front inside
face of the fire chamber, also make sure that
the primary air openings as shown in figure
18 are kept open. (page 12)
5. Ignite the paper.**
BOX 422 • TOWER, MN 55790 • USA • Tel (218) 753-2330 • www.lamppakuuma.com

INSTALLATION INSTRUCTIONS

OPERATION GUIDELINES

typical hot air hookup.
5. Use 6 inch stove pipe to connect the smoke
outlet in the back of the stove to AN AP-
PROVED CLASS A CHIMNEY. Install only
ONE connection to one flue. Make sure you
use at least three metal screws at each joint
connection, refer to figure 9.
6. Install a barometric draft control (field con-
trol 6" RC/BT) as described and illustrated on
page 7 and 9, also see figures 9, 10 & 11.
7. WE SUGGEST THAT A LICENSED ELEC-
TRICIAN BE HIRED TO DO ALL YOUR
ELECTRICAL CONNECTIONS. See wiring
diagram, figure 23, page 14, also see figure
27 page 16.
6. Open ash pan door approximately 1/4" until
automatic draft damper opens.
7. Momentarily hold the fire door open, approx-
imately one-half inch, this will assist in ignit-
ing the kindling and helps to create the initial
draft.
8. Close the fire door and ash pan door tight –
the electronic control automatically monitors
the fire.
** Open ash pan door momentarily, when draft
control is activated – CLOSE ASH PAN
DOOR.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

68710