Download Print this page

Gessi 57917 Manual

Bath mixing program

Advertisement

Quick Links

BATH MIXING PROGRAM
PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN
PROGRAMA MEZCLADORES BAÑO
Art. 57917
Gessi SpA - Parco Gessi
13037 Serravalle Sesia (Vercelli) - Italy
Phone +39 0163 454111 - Facsimile +39 0163 459273
www.gessi.com - gessi@gessi.it

Advertisement

loading
Need help?

Need help?

Do you have a question about the 57917 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gessi 57917

  • Page 1 BATH MIXING PROGRAM PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN PROGRAMA MEZCLADORES BAÑO Art. 57917 Gessi SpA - Parco Gessi 13037 Serravalle Sesia (Vercelli) - Italy Phone +39 0163 454111 - Facsimile +39 0163 459273 www.gessi.com - gessi@gessi.it...
  • Page 2: Caution - Warning

    MUST NEVER BE EXCEEDED, as it may damage and/or cause ruptures and/or leakages and/or even break the product, and present a potential hazard and danger to safety, health and/or property. Following are the technical data with respect to the installation of Gessi plumbing products. ► W orkingpressureshouldnotbelowerthan0,5bar(7,25psi)andnotbehigherthan5bar(72Psi).In case of higher working pressure use a pressure reducer valve.
  • Page 3 Ci-dessous nous indiquons les données techniques concernant l’installation des produits sanitaires Gessi. ► L apressiondeservicenedoitpasêtreinférieureà0,5bar(7,25psi)etsupérieureà5bar(72Psi).En cas de pressions de service plus hautes utiliser une soupape de réduction de la pression.
  • Page 4 1 - ¡CUIDADO!! LES ROGAMOS QUE TENGAN EN CUENTA QUE NUNCA la presión y/o la temperatura máximaaconsejadaNOTIENEQUESERSUPERADA,yaquepodríadañary/ocausarrupturasy/o pérdidasy/oaveríasdelproductoy,porlotanto,representarunriesgoyunpeligropotencialpara la seguridad, la saludad y/o la propiedad. A continuación Les proporcionamos los datos técnicos relativosalainstalacióndelosproductosdegriferíaGessi. ► L apresióndeejercicionotienequeserinferiora0,5bar(7,25psi)ysuperiora5bar(72Psi).Encaso depresionesdeejerciciomayores,utilicenunaválvuladereduccióndelapresión. ►Presiónmáximadeensayodurantelainstalación:8bar(116psi). ► E vitengrandesdiferenciasdepresiónentrelaalimentacióndelaguafríayaquelladelaguacaliente. Lasdiferenciasdepresión,elaguaconunalatocontenidomineralylassustanciasjabonosaspueden...
  • Page 5 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES...
  • Page 6 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Workersnecessaryfortheinstallation Ouvriers nécessaires pour l’installation Obreros necesarios para la instalación DURING ALL INSTALLATION STAGES WE RECOMMEND: - Using protection gloves to avoid leaving fingerprints on the STAINLESS steel surfaces. - NEVER put the shower head on the surface containing the supply nozzles. PENDANT TOUTES LES PHASES DE L’INSTALLATION ON RECOMMANDE: - D’utiliser des gants de protection pour éviter de laisser des empreintes sur les surfaces en acier INOX.
  • Page 7 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Before installation and setting to work Attention! The feeding pipes have to be rinsed thoroughly before the installation of the mixer, so that no shavings, welding or hemp residual or other dirt can be found in the pipes. Foreign bodies can enter the mixer through the rinsed pipes or the general water plant and could damage the washers/ring washers.
  • Page 8 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES General rules for the positioning: - if the doors of the booth open towards the interior, check the best position for installation. - In case of installation on light walls additional supports are needed to guarantee maximum stability. Normes générales pour le choix de la position: - en cas d’ouverture des portes de la cabine vers l’intérieur, vérifier la position meilleure pour l’installation.
  • Page 9 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES...
  • Page 10 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES...
  • Page 11 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Package content: A - Shower head B - Full wall connections C - Stirrups for wall mount D - Fastening set for stirrups E - Installation template F-Wallguard G - Top guard H - Bottom guard I - Carter fastening set L - Installation wrench M - Maintenance set...
  • Page 12 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES 15/16” [24 mm] 3/8” [10 mm] 1/8” [2,5 mm] 3/16” [5 mm] - Installation tools - Outils nécessaires pour l’installation - Herramienta necesaria para la instalación...
  • Page 13: Static Pressure

    Technical data for the plumbing system: -Minimumworkingpressure:29Psi[2bar] -Workingpressure:recommendedoperatingfield43.5÷58Psi[3÷4bar] -Maximumworkingpressure:72,5Psi[5bar](Installapressurereducerforhigherhydraulicpressures) -Maximumworkingtemperature:140°F[60°C] -Weightoftheemptyshowerheadaround33lbs[15Kg](withwateraround35lbs[16Kg]) ART. 57917 DATA FOR THE DIMENSIONING OF THE SYSTEM AND OF THE BOILER Supply pipes for the shower system: DN 1/2”[12mm] minimum Minimum supply required for good operation of shower system STATIC PRESSURE 2.3gpm[20l/min]...
  • Page 14 - P ression maximum d’exercice: 72,5 Psi [5 bar] (Pour les pressions hydrauliques supérieures nous recommandonsl’installationd’unréducteurdepression) -Températuremaximumd’exercice:140°F[60°C] -Poidsdelapommedouchevideenviron33lbs[15Kg](aveceauenviron35lbs[16Kg]) ART. 57917 DONNEES POUR LE DIMENSIONNEMENT DU SYSTEME ET DE LA CHAUDIERE Tuyaux d’alimentation pour le système douche : minimum DN 1/2”[12mm] Alimentation minimum requise pour un fonctionnement correct du système douche...
  • Page 15 - P resión máxima de ejercicio: 72,5 Psi [5 bar] (En caso de presiones hidráulicas superiores, Les recomendamoslainstalacióndeunreductordepresión) -Temperaturamáximadeejercicio:140°F[60°C] -Pesodelrociadorvacíoaprox.33lbs[15Kg](conaguaaprox.35lbs[16Kg]) ART. 57917 DATOS PARA EL DIMENSIONAMIENTO DE LA INSTALACIÓN Y DE LA CALDERA Tubo de alimentación para el sistema ducha: mínimo DN 1/2”[12mm] Alimentación mínima requerida para un correcto funcionamiento del sistema ducha PRESIÓN...
  • Page 16 PLUMBING SYSTEM - INSTALLATION HYDRAULIQUE - INSTALACIÓN HIDRÁULICA InordertocomplywithrequirementsASMEA112.18.1/CSAB125.1needsselectorART. 39601-63001upstreamofutilizationpointsandforeachofthemadditionalflowratereducer ART.R5404. Pour la conformité avec les prescriptions ASME A 112.18.1 / CSAB125.1 nécessite de sélecteurART.39601-63001enamontdespointsd’utilisationetpourchacundeceux-cide réducteurdedébitadditionnelART.R5404. Para cumplir con los requisitos ASME A 112.18.1 / CSAB125.1 necesita de selector ART. 39601-63001arribadelaslíneasdeusuarioy,paracadaunadeellas,deunreductorde caudaladicionalART.R5404.
  • Page 17 PLUMBING SYSTEM - INSTALLATION HYDRAULIQUE - INSTALACIÓN HIDRÁULICA 1/2”NPT - m DN 9/16” [15mm]...
  • Page 18 PLUMBING SYSTEM - INSTALLATION HYDRAULIQUE - INSTALACIÓN HIDRÁULICA Htot 82-11/16”÷86-5/8” 63”[1600mm] [2100÷2200mm] 82-11/16”÷90-9/16” 66-15/16”[1700mm] [2100÷2300mm] 1-15/16" 3-9/16" 9-13/16" 86-5/8”÷92-1/2” 70-7/8”[1800mm] [50mm] [90mm] [250mm] [2200÷2350mm] 86-5/8”÷94-1/2” 74-13/16”[1900mm] [2200÷2400mm] H = Customer height - Hauteur client - Altura cliente H1***= R ecommendedheight-Hauteurconseillée-Alturaaconsejada HC= W aterinletheight-Hauteurpriseeau-Alturatomadeagua HD = Template base height - Hauteur base gabarit - Altura base plantilla Htot = Total height needed for the installation - Hauteur totale nécessaire pour l’installation - Altura total...
  • Page 19: Installation - Installation - Instalación

    INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 1 Fig. 2 1/2”NPT - m DN 9/16” [15mm] Fig. 3 Fig. 4 Holes should be properly aligned. Les trous doivent être bien alignés. Los agujeros tienen que ser bien alineados.
  • Page 20 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 5 Fig. 6 15/16” [24 mm] use hemp or teflon employer chanvre ou teflon usarcáñamooteflon Fig. 7...
  • Page 21 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 8 Fig. 9 3/8” [10 mm] Fig. 10 Stirrups should be properly aligned. Les étriers doivent être bien alignés. Las bridas tienen que ser bien alineadas.
  • Page 22 INSTALLATION - INSTALLATION - INSTALACIÓN 3/8” Fig. 11 [10 mm] Fig. 12 1/8” [2,5 mm]...
  • Page 23 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 13 Fig. 14 Fig. 15 3/16” [5 mm] ~1-15/16” [50 mm] 3/16” [5 mm]...
  • Page 24 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 21 Fig. 22...
  • Page 25 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 22 Fig. 23 1/8” [2,5 mm]...
  • Page 26: Maintenance

    MAINTENANCE - ENTRETIEN - MANUTENCIÓN MAINTENANCE •   S houlditbenecessarytoreplaceoneormorecomponents,contactanauthorizedretailer orvisitWWW.GESSI.COM •Productmaintenanceshouldbemadeonlybyqualifiedstaff • F or periodical maintenance and cleaning of the shower head see the handbook in the maintenance set, included in the package ENTRETIEN • S ’ilestnécessairederemplacerunouplusieurscomposants,contacteruncentreautorisé ouvisiterlesiteWWW.GESSI.COM •L’entretienduproduitnedoitêtreeffectuéquepardupersonnelqualifié...
  • Page 28 GIS004410-R2...