SILO DUST COLLECTOR / FILTER UNIT
HYVENT
INSTALLATION AND OPERATION MANUAL
Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire
B98 7DP, UK
Tel: +44 (0)1527 406800 fax. +44 (0)1527 406810
Email: sales@hycontrol.com Web: www.hycontrol.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYVENT and is the answer not in the manual?

Questions and answers

Summary of Contents for Hycontrol HYVENT

  • Page 1 Hyvent Manual v1.3 MS0820 SILO DUST COLLECTOR / FILTER UNIT HYVENT INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire B98 7DP, UK Tel: +44 (0)1527 406800 fax. +44 (0)1527 406810 Email: sales@hycontrol.com Web: www.hycontrol.com...
  • Page 2: Table Of Contents

    INDEX 1. INTRODUCTION..................1 Pressure system regulations...............2 Explosion prevention...................2 Usage......................2 Health & Safety ...................2 2. SUPPLY SERVICES REQUIRED...............2 Compressed air supply ................2 Electrical supply ..................3 3. INSTALLATION ..................3 Handling......................3 Installation and assembly................3 Supply connection..................4 Cartridge installation ...................4 Commissioning ...................5 4.
  • Page 3: Introduction

    1. INTRODUCTION The Hycontrol Hyvent dust collector and filter unit has been designed to form an integral part of Hycontrol's advanced SHIELD and SHIELD Lite silo protection system (SPS). Please refer to other manuals for further information on the other equipment supplied as part of the SPS. Please read this manual carefully before using the Hyvent unit.
  • Page 4: Pressure System Regulations

    Usage The Hyvent is specifically designed for the handling of dry dusts in air and must not be used for any other purpose. Users should always consult with Hycontrol concerning the application of the equipment and the product being handled.
  • Page 5: Electrical Supply

    Apply a suitable sealant for the application and working conditions (silicon is recommended) using two beads, either side of the bolt holes, ensuring this will form a continuous seal with no gaps. Secure the unit in place using suitable fixings (not supplied). www.hycontrol.com...
  • Page 6: Supply Connection

    - a metal core with top flange and a pleated media cone with end caps. Remove the metal core from the old media cone and fit to a new media cone. 4.0 m² cartridges are one piece items for complete replacement. www.hycontrol.com...
  • Page 7: Commissioning

    Note: Unless otherwise specified, the cleaning control and manifold have been tested and confirmed to be fully functional prior to despatch from Hycontrol. With the exception of power supply to the controller and fan (if fitted) along with a compressed air supply to the manifold no other connections are required.
  • Page 8: Start Up

    Ensure air and power supplies are connected as specified. Start the cleaning system prior to product transfer / airflow into the silo. Allow the cleaning system to continue running for several minutes after product transfer / airflow is complete (this will be operated automatically by the Hycontrol silo protection system).
  • Page 9: Maintenance And Service

    Measure and record static pressure (if possible) Record controller settings Hycontrol offers comprehensive Service and Maintenance Support contracts which cover the aforementioned requirements. Please contact Hycontrol for further information. Specific industries and applications may require more frequent inspection. More information regarding such applications can be obtained from the HSE or local authorities.
  • Page 10: Troubleshooting

    Note: the stated duties are normal conveying rates. Allowances have been made for the surge experienced at the end of a load when transfer is from a lorry tanker. For specific applications and recommendations please contact Hycontrol. No responsibility is accepted for any application unless specific recommendations have been made by Hycontrol in writing.
  • Page 11: Spare Parts

    6 (21.0) / 7 (24.5) ** Please note: this is the standard polyester media – other media’s are available for specific applications – if in doubt about media type please refer to Hycontrol quoting unit serial number. 10. CONTROLLER SET UP AND OPERATION Set parameters in set mode 1.
  • Page 12: Basic Sequence Controller Codes

    If contact C6 is open, the cleaning stops at the end of the whole cleaning cycle, the display shows ‘P’, which means stop for low dP. If contact C6 is closed, the cleaning cycle restarts from the beginning. NOTE C6: Use a jumper for C6 if it is not used with active inputs (see F01) www.hycontrol.com...
  • Page 13 JP3: Output voltage selection between AC and DC only with JP2 set to 24v. ATTENTION: set F08 to the same output voltage that has been selected by means of the jumpers to adjust the short-circuit trip threshold. Otherwise, this might cause a malfunction or damage to the sequencer. www.hycontrol.com...
  • Page 14: Technical Drawings

    12. TECHNICAL DRAWINGS www.hycontrol.com...