Download Print this page

jablotron JA-111R Quick Start Manual page 2

Bus interface for ja-100 wireless devices

Advertisement

The JA-111R BUS interface for JA-100 wireless devices
5.
Shorten the BUS cable to a suitable length and remove the top
insulation (for a better positioning of the wires in the cover).
6.
Connect the BUS cable to the labelled terminal from the PLV-
JA111R mounting package.
When connecting the radio module
to the BUS, always switch the power off.
7.
Plug the connected terminal (11) to the counterpart of the terminal
on the radio module (orientation given by the locks of the terminal).
8.
Close the radio module cover. Wires of the BUS cable must be only
in the space separated by the cable separator (15).
14
15
16
Figure 4: 10 – antenna; 11 – plug and play BUS connector;
12 – BUS cable; 13 – rear part of the cover; 14 – segment for tamper
detection; 15 – cable separator; 16 – holes for BUS cable
Module enrollment into the system
1.
Proceed according to the control panel installation manual.
Basic procedure:
a.
When the system is switched on, the yellow LED on the radio
module starts flashing repeatedly to indicate that the module
has not yet been enrolled into the system.
b.
Go to the F-Link software, select the required position
in the Devices tab and launch the Enrollment mode
by clicking on the Enroll option.
c.
Click on Add new BUS devices, select the radio module and
by a double press confirm enrolling – the yellow LED goes off.
Notes:
The module can also be enrolled into the system by entering its
production code in the F-Link software. You can find the production
code on the sticker (7) placed on the module. All numbers under the
bar code must be entered (example: 1400-00-0000-0001).
If you want to remove the radio module from the system, erase
it from its position in the control panel.
More information about the installation of more radio modules to the
system and about the RF signal level check in the F-Link software
can be found in the control panel installation manual.
To set the radio module to comply with
the Grade 2 classification, use the System
profiles function in the Parameters tab
in the F-Link software (the Default profile does
not meet the Grade 2 classification); for more
information see the JA-10xK control panel
installation manual.
The JA-111R BUS interface for JA-100 wireless devices
Setting the radio module properties
The module properties can be set in the Devices tab in the F-Link
software. At the module position, click on the Internal settings option
to open a dialogue window where you can set the following parameters:
Activation indicated by LED: The default setting is that the radio
module indicates communication with wireless devices by a red LED.
This indication can be disabled.
RF jamming level: It is disabled as a default. However, it can be set
to two levels – low (interference lasts longer than 30 s per one minute)
and high (interference lasts longer than 10 s per 20 s). If the detection
is enabled, the system reports a fault or a tamper when the communica-
tion band interference / RF jamming occurs.
Enrollment signal: When this option is used, the module sends
an enrollment signal (intended only for wireless devices with a built-in
receiver, for example JA-150N).
Power
Current consumption in standby mode
Current consumption for cable selection (maximum)
Communication band
Maximum radio-frequency power (ERP)
RF range
Dimensions
Weight (PBC only)
Classification
10
Operational environment
Operational temperature range
11
Average operational humidity
Certification body
Complies with
12
EN 50131-5-3+A1, ETSI EN 300 220-1-2, EN 50130-4 ed. 2+A1,
Can be operated according to
JABLOTRON ALARMS a.s. hereby declares than the JA-111R
is in a compliance with the relevant European Union harmonisation
legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU,
2011/65/EU, when used as intended. The original of the conformity
assessment can be found at
Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return this product to the dealer
or directly to the producer after use.
2 / 2
Technical specifications
from control panel BUS 12 V DC (9 ... 15 V)
868.1 MHz, JABLOTRON protocol
Security grade 2 / Environmental class II / ACE type B
(According to EN 50131-1)
75 % RH, non-condensing
Trezor Test s.r.o. (no. 3025), Telefication B.V.
EN 50131-1 ed. 2+A1+A2, EN 50131-3,
EN 55032, EN 62368-1, EN 50581, T 031
www.jablotron.com
35 mA
80 mA
25 mW
300m
43 x 160 x 23 mm
70 g
Indoor general
-10 °C to +40 °C
ERC REC 70-30
– section
MLR53204

Advertisement

loading