CARE AND MAINTENANCE
FILTER REPLACEMENT
WARNING:
To reduce the risk of injury from accidental
starting, unplug power cord before changing
or cleaning the lter. The lter should be
cleaned often to maintain peak vac performance.
WARNING:
Do not remove lter cage and oat. The
oat prevents water from entering the impeller
and damaging the motor. The cage prevents
ngers from touching the moving impeller.
IMPORTANT:
To avoid damage to the blower wheel and
motor, always reinstall the Clean Connect™
lter before using the vac for dry pickups
and wet pickups.
IMPORTANT:
After cleaning, check the lter for tears or
small holes. Do not use a lter with holes
or tears in it. Even a small hole can cause
a lot of dust to come out of the vac.
Replace it immediately.
NOTICE:
Before installing the lter on the vac, clean
the area of the lid so that the lter will seal
against the lid and stop small particles from
bypassing the lter bag. If the lter is clean
and not damaged, replace it on the lter
cage. If it cannot be reused, place a new
lter over the lter cage.
NOTICE:
Clean the lter in an open area. Cleaning
should be done outdoors and not in
living quarters.
CLEANING:
To keep the wet/ dry vac looking its best,
clean the outside with a cloth dampened
with warm water and mild soap.
To clean the tank:
1. Dump out debris.
2. Wash tank thoroughly with warm water
and mild soap.
3. Wipe out with dry cloth.
STORAGE:
Before storing the vac,the dust tank should
be emptied and cleaned. The cord should
be wrapped and hung on the unit and the
accessories should be kept in mesh bag
so they can be readily available. The vac
should be stored indoors.

TROUBLESHOOTING

Minor problems often can be xed without calling
customer service.
PROBLEM
Motor does not run
Suction capacity
decreases
Vacuum stops
running
Dust comes out
while vacuuming
7
SOLUTION
Check power cord, plugs and outlet.
Ensure the on/ off switch is in the
ON position ( I )
Remove blockages in the suction
nozzle, suction tube, suction hose
or lters.
Replace the paper or eece dust bag.
Check for proper installation of the
lters.
Clean or replace the lters.
Empty the dust tank, refer to
the tank
Operating
under
instructions.
Thermal overload has been tripped:
1. Turn the vacuum off and
disconnect vacuum cleaner from
power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug the power cord into an
appropriate outlet and turn on/off
switch to the ON position ( I ) to
test. If vacuum will not restart
call 1-888-899-0146
Check for proper installation of the
lters.
Ensure lters are not damaged;
replace if necessary.
Ensure lter seals are in place and
are secure.