1 inch pipe and is plumbed throughout with 1 inch “schedule 80” PVC. Be sure that there is at least 74" of room, floor to ceiling, in the location where your SpringHouse is to be installed. Otherwise you will not be able to install and/or remove the UV lamp and the quartz sleeve.
Back flow Preventer All filter canisters are FDA compliant. * Pressure Regulator Preset to 60 psi. Supplying pressures below 40 psi will result in a noticeable reduction in flow through the SpringHouse. ** See page 15 for more information on your Warranty.
Failure to change filter or to perform necessary maintenance in accordance with recommendations contained in this manual could result in diminished performance and reduced water treatment. Operating the SpringHouse without all filters installed as recommended could adversely affect the treatment performance of the unit. Call Tech Support (423.798.6700) prior to modifying filter configuration.
Failure to do so can result in damage not covered by your SpringHouse warranty. Installation by a licensed plumber is recommended. • SpringHouse can be installed outdoors but must be protected from freezing, excessive heat and direct sunlight. Failure to do so can...
Page 7
CAUTION: failure to properly ground the unit could lead to serious injury or death. 1. Locate the Grounding Lug on the plumbing side of SpringHouse to be used for grounding. 2. Insert provided grounding wire into Grounding Lug connection point and tighten clamp screw.
Page 8
ASSEMBLING YOUR SPRINGHOUSE FILTERS WASH HANDS THOROUGHLY AND FREQUENTLY WHILE HANDLING FILTER WORK WITH ONLY ONE FILTER CANISTER AT A TIME TO AVOID CARTRIDGES TO AVOID CONTAMINATING THE CARTRIDGES. MIXING UP THE FILTERS. DO NOT OVER TIGHTEN THE CANISTER. FILTER CANISTER INSTALLATION NOTE: FILTER PACKING MUST BE REMOVED BEFORE INSTALLATION.
Page 9
ULTRAVIOLET (UV) LAMP AND SLEEVE ASSEMBLY WARNING: THE SLEEVE IS FRAGILE. ROUGH HANDLING OR MISALIGNMENT WILL CAUSE IT TO BREAK. CAUTION - SHOCK HAZARD: BE SURE UNIT IS PROPERLY GROUNDED (SEE PAGE 7) AND AREA IS FREE OF STANDING WATER BEFORE PLUGGING UNIT INTO RECEPTACLE. figure 1 1.
CHARGE THE SYSTEM Turn on water: 1. Uncoil clear tubing attached to pressure relief valve on top of unit, and place end of tube into bucket or drain. Open pressure relief valve. 2. Gradually turn on water to unit being careful to secure the plastic hose into a bucket or drain. 3.
REPLACING FILTER CARTRIDGES CAUTION - SHOCK HAZARD: BE SURE UNIT IS UNPLUGGED BEFORE PROCEEDING WITH FILTER REPLACEMENT. Replacing filter cartridges (canisters #1,2,3,5, & 7), ultraviolet light 11. Insert a new cartridge into the canisters or refill (canister #4), or polyphosphate crystals (canister #6) polyphosphate crystals as required.
1. Water pressure to the house from the source has been reduced 2. Inlet or Outlet Valve on SpringHouse Partially Closed 2. One or more filter cartridges in the SpringHouse unit are clogging or otherwise reaching the end of their useful life 3.
(1) year from the date of original shipment. In the event that such defects become evident during the warranty period, EcoQuest will, at its option, replace or repair the item without charge.
Title: Director of Engineering Date: 8/8/05 ™ ™ ™ ™ EcoQuest , Healthy Living Technologies , SpringHouse , are Trademarked by EcoQuest International. 65-00008-005 EcoQuest International “Healthy Living Technologies” ® is Registered by EcoQuest ™ International. Rev. 0906...