MyTana ML2011 AccuCane User Manual

Advertisement

Using MyTana's ML2011 AccuCane Locator

Signal Strength Gauge

Sensitivity
Dial
Estimated
Depth
Readings
The color disks in the image below
represent the signal strength area
as indicated by your gauge.
The camera or sonde will be in the center
of the strong signal (darker red) area.
Be aware of Ghost areas (represented in
purple) that are a few feet in front and
back of the strongest signal. They will
cause the needle to spike, but not as
much as the true strong signal.
Weak
Ghost
081617
Test both the transmitter or sonde and locator before entering into the pipe.
1. Set the camera to transmit mode or activate sonde
2. Turn on the ML2011
3. Turn the Sensitivity Dial to a

4. Locating

Power On/Off
Toggle Button
As you watch the needle, slowly move around
your target area until the needle spikes. Stop.
Power
Light
Turn the Sensitivity Dial down
in the middle of the gauge.
Null Area
Needle
Strong
drops
www.MyTana.com
746 Selby Ave • St. Paul MN, 55104
fax: 651.222.1739
high depth reading
(clockwise)
(counter-clockwise)
Pinpoint the location
Change one variable (below) at a time until the
needle spikes, then adjust the Dial down again
Repeat until you are able to keep the needle in
the middle of the gauge at the lowest
possible sensitivity level. Stop.
u
Locatable
(see next page)
BUZZING If you feel a vibra-
tion or buzzing in the handle,
turn the sensitivity down.
Important: Always keep the
locator head flat and close to
the ground.
until the needle is
Move forward and back – adjust (watch
for spikes caused by ghost signals)
Move side to side – adjust
Rotate the head – adjust (see below)
The locator head MUST be parallel to the
camera head or sonde
(as shown below left)
If the orientation of the camera head is not
known, slowly rotate the locator head
until the signal becomes stronger.
Not Locatable
1.800.328.8170
Factory Direct Customer Service
M –F 7am – 5pm CST
Competent • Polite • Clear

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML2011 AccuCane and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MyTana ML2011 AccuCane

  • Page 1 Using MyTana’s ML2011 AccuCane Locator Signal Strength Gauge Test both the transmitter or sonde and locator before entering into the pipe. Sensitivity Dial 1. Set the camera to transmit mode or activate sonde 2. Turn on the ML2011 3. Turn the Sensitivity Dial to a...
  • Page 2 Read Depth Tips Keep the locator head flat against the ground in the exact • If the Power Light on the ML2011 is blinking, change the position when you locate the camera or sonde (step 4). batteries. The ML2011 uses 2 9V batteries. Battery compart- ment is located opposite the control panel.

Table of Contents