Page 2
Dear Customer, We wish to congratulate you for choosing INTERGLIDE AUTOCONTRLS system, leading supplier of various type automatic opening systems for Swing Gates, sliding Gates, Rolling Shutters, Garage shutters, Boom Barriers, Sliding Glass Doors etc, which are developed in India. Hence, we assure you trouble free operation and committed service at all time to come.
INSTRUCTIONS SITE INSPECTION Before begin to install the Automatic System, please check following. 1. Structure of the Gate Poll should be sufficiently strong to support the mechanism. The hinges must function efficiently and there must be no friction between moving parts and fixed parts, other than usual. 2.
Page 4
Arm Gate Motor: Motor with gear assembly to open / close the gate. Control Box- This consists of Microprocessor based control circuits to supply drive power to the motor. It also contains back up Battery and Radio Frequency Receiver. Remote Transmitter: This is hand held remote switch to signal open/close operation.
2. Lubricate the Gate Hinge and check the load on the gate leaf with a spring balance at a point 1 Mt from the hinge. If the load is more than 5 Kg (generally for Cast Iron Gates) it is ideal to use either SW 800, UG 800 or WMS 800. If less than 5 Kg SW 300, UG 300 or WMS 300 can be used.
Page 6
SWING GATE OPENER - SW 300 INSTALLATION- Auto Gate OPERATION SETTINGS- Auto Gate Connect both motors Ensure that the Pillar is strong electrically, to the enough to mount the Motor Bracket. control board. Mount Base Bracket with Anchor Keep the gate half Bolt &...
Page 7
Prepartion for Installation In order to have a smooth installation, please make sure that 1. The gate work manually, without any obstacle 2. Hinges are stabe and in good condition. Fix the rear support Clamp on the gate post. If necessary, please adjust the support length.
Page 8
If the size on the diagram A is changed, then the opening angle will be changed (90 – 110 degrees) Please change the size according to following rule. 1. 132<A<145,132<b<145 mm 2. If the opening angle is more than 90 degrees, then A+B<C 3.
MANUAL RELEASE If Power fails or on motor Stoppage, please open the waterproof cover on the Motor Arms and insert the release key and turn quarter turn clockwise. This operation releases the gear from the motor and the gate can be manually moved. Do this for the other gate also.
Page 10
Installation of EM Lock. EM Lock is generally fixed to the Gate Leaf, which needs to travel more than other. If same, it can be fixed to the gate near control box, so as to reduce wiring. Motor in the Gate Leaf with lock is termed as M1, and other M2. Close the gate properly and fix the LOCK BASE to the ground so that both leaves are blocked in the upper rubber part of the base.
Page 11
Open - commands only OPEN. Close - Commands only Close. In the Remote Transmitter, Switch A is meant for Dual gate operation and Switch B for Single CONTROL BOARD Settings The control Board is equipped with proper Battery charging circuit and Overload detection circuit.
OPEN Command allows only Open. CLOSE Command allows only Close. IR Photocell- Grounding IR, senses obstruction and a closing gate stop and reverses. 2S – Manual Switch for Dual gate operation. Grounding activates, alternatively open- close. Flash- Intermittent closed contacts of 24V. Lock –...
Page 13
Fix the Motor clamp as shown: If the Pillar is Iron, weld supporting clamps. If Concrete use Anchor Bolts. 1. Release the GEAR MOTOR ARM. OPEN both gates. 2. Extend the Lever Arm fully outwards, by rotating the Arm Extension. 3.
Page 14
Components: 1. PWM SOLAR CONTROLLER 24V/ 10Amp 2. 2 Nos of Solid Battery 12V /7AH, connected in Series. 3. 2Nos of 12V /10W Solar Panel connected in Series. Controller is set to factory default settings.
WARRANTY Scope & Limitts INTERGLIDE offers following warranty in respect of AUTOMATION SYSTEM supplied by us. Every possible care and precaution have been taken to ensure quality in respect of the material and workmanship of the system supplied by us. INTERGLIDE warrants the original purchaser of AUTO GATE SYSTEM for a period of Years from the date of purchase, the product shall be free of defects in material and workmanship under normal use.
Page 16
Frequently Asked Questions. Gate is not opening/ closing Grease the gate Hinges. full Check the stability of mounting Clamps Remote control not Check for light in the remote. If mild responding replace the battery on the Remote- 12v alkaline. The life of the battery is expected to be one year.
Page 17
Products from this group I N T E R INTERGLIDE AUTOCONTROLS 3 / 463A, KADAYIRUPPU P.O., KOLENCHERRY ERNAKULAM- 682311, KERALA E Mail – info@interglide.in Website: www.interglide.in WORKS: 94/201,3 Cross, Sivaji street T Nagar, Chennai- 600 00...