Leakage control
Hide thumbs Also See for ABS CA 461:

Advertisement

Quick Links

Leakage Control Type ABS CA 461
L1
N
110-230VAC
CA 461
CA 461
3
4
5 6
3
4
5 6
Installation guide
en
www.sulzer.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the ABS CA 461 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sulzer ABS CA 461

  • Page 1 Leakage Control Type ABS CA 461 110-230VAC CA 461 CA 461 Installation guide www.sulzer.com...
  • Page 2 Leakage: Sensors must be in parallel. It is very important to have in mind that this practice avoids alarms having to be distinguished. Sulzer highly recommends to use one module per signal to allow not only distinguishing but also acting in a different way according to the alarm category/severity.
  • Page 3 TECHNICAL DATA Technical data CA 461 Leakage sensor voltage 12 VDC Max sensor current < 15 µA Leakage detection threshold < 100 kohm Alarm on delay ~10 seconds Ambient operating temperature –20 to +50 °C (–4 to +122 °F) Ambient storage temperature –30 to +80 °C (–22 to +176 °F) Degree of protection IP 20, NEMA: Type 1...
  • Page 4 Sulzer Pump Solutions (Kunshan) Co., Ltd, No.8 West Chenfeng Road, Kunshan, Jiangsu Province, 215300, China Tel. +86 512 36606388. www.sulzer.com Copyright © Sulzer Ltd 2020...