Download Print this page
Ranger RCI-2950DX Alignment Procedure

Ranger RCI-2950DX Alignment Procedure

Advertisement

Quick Links

Equipment required for Alignment procedure:
• DC Power Supply ( 13.8 Vdc, 20A )
• Oscilloscope (50 MHz), with X10 probe
• 50 Ω dummy load
• Frequency Counter - 100 MHz
• Digital voltmeter or Multimeter
• RF Signal Generator
To view Main PCB Adjustment for location of adjustment points, please see this
drawing After viewing, press "back" to return to this page.
The following steps are required to re-align the RCI-2950DX:
Caution: Alignment should only be attempted by personnel trained in RF
product testing and alignment.
PLL Synthesizer / Oscillator Frequency Alignment:
1. PLL2 - VCO Voltage:
A. Set radio to 24.890 MHz, AM RX mode, connect multimeter to TP10.
Adjust L14 for 1.0 Vdc ± 0.1.
B. Set frequency to 29.699 MHz, AM RX mode, connect multimeter to TP10.
Adjust L14 for 4.5 Vdc ± 0.1.
2. PLL1 - VCO Voltage:
A. Set radio to 24.890 MHz, AM RX mode, connect multimeter to TP10.
Adjust L13 for 1.0 Vdc ± 0.1.
B. Set frequency to 32.000 MHz, AM RX mode, connect multimeter to TP10.
Adjust L13 for 6.5 Vdc ± 0.1.
2. AM Frequency:
Set radio to AM RX mode, clarifier to 12 o'clock,. Connect frequency counter to
TP16.
Adjust VC2 to 10.1 MHz ± 10Hz.
3. VCO Output:
Set radio to 28.000 MHz, AM RX mode, connect oscilloscope to TP3.
Adjust L17 to 38.6950 MHz (maximum output).
4. AM OSC:
Set radio to AM TX mode, modulation off, connect frequency counter to TP5.
Adjust L18 to obtain 10.6950 MHz ± 10Hz.
5. USB OSC:
Set radio to USB TX mode, modulation off, short TP6 to ground, connect
frequency counter the TP5.
Adjust L20 to 10.6975 MHz ± 10Hz.
6. LSB OSC:
Set radio to LSB TX mode, modulation off, connect frequency counter to TP5.
Adjust L19 to 10.6925 MHz ± 10Hz.
This completes this stage of the alignment procedure.
• Audio Generator
• Automatic Distortion Meter
• SINAD Meter
• RF Wattmetter ( 25~60 MHz, 100W )
• Automatic Modulation Meter

Advertisement

loading

Summary of Contents for Ranger RCI-2950DX

  • Page 1 To view Main PCB Adjustment for location of adjustment points, please see this drawing After viewing, press "back" to return to this page. The following steps are required to re-align the RCI-2950DX: Caution: Alignment should only be attempted by personnel trained in RF product testing and alignment.
  • Page 2 Receiver Alignment: 1. Receiver Setup: Put the mode selector on AM, the RF gain fully clockwise (maximum gain), squelch to minimum (unsquelched), volume at 2 o'clock, set frequency to 28.295 MHz, and NB/ANL to OFF. Connect signal generator set at RF carrier frequency of 28.295 MHz, AM modulated with a 1 KHz audio tone at 30% modulation level.
  • Page 3 This completes the Receiver stage of the alignment procedure. Transmitter Alignment: 1. Driver BIAS: Remove the "Shorting PCB" from TP7, TP8, and TP9. Set radio to USB mode, connect current meter to TP9 (+) and TP8 (-). Adjust VR11 to obtain 50 mA. 2.