RF SG setting 24.890 MHz.
Set radio to 29.699 MHz, AM RX mode.
RF SG setting 29.699 MHz.
USB Sensitivity Set radio to USB RX mode.
VOL. Control Fully Clockwise.
RF SG setting 28.001 MHz, 0.5uV. Mod off.
LSB Sensitivity Set radio to LSB RX mode.
VOL Control Fully Clockwise.
RF SG setting 27.999 MHz, 0.5uV. Mod off.
FM Distortion
Set radio to 28.000 MHz, FM RX mode.
Set MODE switch to FM mode.
RF SG setting 28.000 MHz, 1mV. Mod 3KHz.
NB Adjust
Set radio to 28.000 MHz, AM RX mode.
RF SG setting 28.000 MHz, 100uV. Mod off.
Set NB/ANL/OFF switch to NB/ANL position.
Connect Voltmeter to TP1.
AM Squelch
Set radio to 28.000 MHz, AM RX mode.
Set SQ Control Fully Clockwise.
RF SG setting 28.000 MHz, 1mV. Mod 30%.
SSB Squelch
Set radio to USB RX mode.
Set SQ Control Fully Clockwise.
RF SG setting 28.001 MHz, 1mV. Mod off.
AM S/RF Meter
Set radio to 28.000 MHz, AM RX mode.
AM S-Meter
RF SG setting 28.000 MHz, 100uV. Mod 30%.
SSB S-Meter
Set radio to USB RX mode.
RF SG setting 28.001 MHz, 100uV. Mod off.
Figure 6-1 Transmitter test setup
- 22 -
24.890 and 29.699
MHz
L11, L12
Audio Output > 2V
S/N > 10 dB
L11, L12
Audio Output > 2V
S/N > 10 dB
L4
Audio Output > 3V
Distortion < 10%
L1
DC Voltage to max.
> 2V
VR4 Slowly
Adjust very slowly
until
squelch
open.
VR3 Slowly
Adjust very slowly
until
squelch
open.
VR1
"6 bar" on the Level
Meter Indicator and
Meter needle to S9 on
the S scale.
VR2
"6 bar" on the Level
Meter Indicator and
Meter needle to S9 on
the S scale.
just
just