Z9000 Series Manual
Copyright 2002 Varitronics Inc.

Advertisement

loading

Summary of Contents for Varitronics Z9000 Series

  • Page 1 620 Parkway Broomall, PA 19008 610-356-3995 www.varitronics.com Varitronics Inc. Z9000 Series Manual Copyright 2002 Varitronics Inc.
  • Page 2 Thank you for purchasing the Z9000 series Ophthalmic Control System. Please carefully read this manual to get the best performance, and place the manual in a convenient location for future reference. PRECAUTIONS Installation (1) Never position the components of the Z9000dt, Z9000-1P, or Z9000-2P Ophthalmic Control System where they will be exposed to moisture, direct sunlight, dust, salty air, chemical storage areas, excessive temperature or humidity.
  • Page 3 SAFETY CONCERNS The Z9000 series Ophthalmic Control Systems is one of the safest systems on the market today. It has been engineered with many safety features to prevent shock and fire hazard. In addition there are no electromagnetic interference concerns. Be sure to observe all precautions as stated in this manual.
  • Page 4 CONTENTS 1. NOMENCLATURE 2. PERFORMANCE AND SPECIFICATIONS 3. INSTALLATION 4. SYSTEM OPERATION 5. ADJUSTMENTS: Programming the Z9000 Ophthalmic Control System 6. MAINTENECE 7. TROUBLESHOOTING 8. TERMS OF TRANSPORTATION APPENDIX A: Z9000 PC Board/Schematic APPENDIX B: Z9000 Wiring Diagrams APPENDIX C: Z9000 Product Label APPENDIX D: Z9000 Physical Specification Sheets APPENDIX E: Z9000 Photos...
  • Page 5 1. NOMENCLATURE 1.1 Printed Circuit Board Overview: 1.1.1 The Z9000 PC Board provides discreet logic control over both room lighting and low voltage auxiliary devices. The board also recharges battery operated handheld ophthalmic devices (provided by others). 1.1.2 The board has three user changeable fuses and one internal fuse that is only to be accessed by a factory authorized technician.
  • Page 6 2.0 PERFORMANCE AND SPECIFICATIONS 2.1 Performance Description 2.1.1 The Varitronics’ Z9000 Ophthalmic Control System is a device used for coordinating the switching of incandescent and fluorescent room lighting (the fluorescent lighting is optional) with the instrumentation and test devices used in the ophthalmologic exam room.
  • Page 7 60” above floor, 36” from sidewall. It requires a single gang box and a 4 conductor low energy wire provided by Varitronics. This wire runs back to Box “B”. Follow the color code when installing the Hanger to the box. Voltage load: 6VAC, 1 amp maximum.
  • Page 8 Wires shall run to Power Box “A”, wire #7. Maximum load: 300 watts. 3.9 FINAL NOTES: 3.9.1 For final installation please refer to Varitronics wiring schematic. 3.9.2 The Z9000-1P must be installed in moveable cabinets only. 3.9.3 It is recommended that a 2.75” hole be drilled in the counter top. A grommet, which eases passage of the cables, is provided with each unit.
  • Page 9 4.3 Touch the DIM switch on the control panel; adjust the dimmer to the required dim point. Touch the DIM switch again; the lights should be fully on. Touch the OFF switch and the lights should go off. Touch the OFF switch again the lights should come on.
  • Page 10 5.1.1 Switch Bank 1- First Well Dipswitch Dipswitch Function Muscle light Fixation Room lights dim Room lights off 5.1.2 Switch Bank 1- Second Well Dipswitch Dipswitch Function Muscle light Fixation Room lights dim Room lights off 5.1.3 Switch Bank 1- Third Well Dipswitch Dipswitch Function Muscle light Fixation...
  • Page 11 CAUTION: Do not use a higher wattage bulb. Only use the supplied bulb extractor to remove and replace bulbs. Do not use forceps or any other metal tipped device to extract bulbs. Sever damage to the equipment can occur. 6.2.1 First turn the power supply off. 6.2.2 Remove the plastic lens cap form the switch or monitor light by grabbing it between you thumb and fore finger and firmly pull out.
  • Page 12 7. TROUBLESHOOTING 7.1 If the Z9000 does not function properly, check the following points before calling for factory assistance. 7.1.1 Problem: Room lights do not go on when using light switch at door. Solution: Check to see if Power LED is on, Indirect is on its hanger, slit lamp is turned off, and handheld instruments are in wells.
  • Page 13 APPENDIX A...
  • Page 14 0 Volts Well Common Recharge Voltage Recharge Voltage Recharge Voltage +5 Volts Switch Return Well Switch Return Well Switch Return Well Projector Projector Muscle Muscle Fixation Fixation Aux1 Aux1 Lamp Lamp Dimmer Dimmer Indirect Feed Child Pwr LED Com: Low Voltage Aux2 Child Aux2 DC...
  • Page 15 APPENDIX B...
  • Page 19 APPENDIX C...
  • Page 20 Disconnect all power before servicing with same type and rating of fuse only. by a qualified technician. No user serviceable parts inside. MODEL: Z9000 Varitronics Inc. Desktop 620 Parkway Broomall, PA 19008 Full Load: 700 Watts Tele: 610-356-3995 115 VAC 60 Hz Only Serial No.
  • Page 21 APPENDIX D...
  • Page 22 Specification Sheet: Z9000...
  • Page 23 Specification Sheet: Z9000-1P...
  • Page 24 Specification Sheet: Z9001-2P...
  • Page 25 Specification Sheet: FW9001-2P...
  • Page 26 Specification Sheet: Z9001-2P...
  • Page 27 Specification Sheet: Z9001-2P...
  • Page 28 APPENDIX E...
  • Page 29 PHOTOS OF Z9000 SERIES OPHTHALMIC CONTROL SYSTEMS...
  • Page 30 PHOTOS OF ACCESSORIES...
  • Page 31 PHOTOS OF ACCESSORIES...