Page 1
Operating Manual for 3-Person Hands-Free Floor Mount Stainless Steel Wash Station AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.5 Columbia does not recommend use with harsh chemicals. Product Compliance NSF/ANSI 2 Food Equipment, NSF/ANSI 372 Lead-Free Compliant, ASME A112.18.1 of Domestic and Foreign Parts...
COLUMBIA SPECIFICATIONS WA S H S TAT I O N W I T H E L E C T R O N I C S E N S O R A C O R B AT T E R Y P O W E R E D Leg Assembly 800.626.2117 columbiasinks.com info@columbiasinks.com...
COLUMBIA SPECIFICATIONS C A R E A N D M A I N T E N A N C E Care and Maintenance Regular cleaning will preserve the appearance and integrity of the surface. Stainless steel can easily be cleaned and kept stain-free using various methods. Recommendations: •...
COLUMBIA SPECIFICATIONS S E N S O R FA U C E T S SANI-LAV Sensor Faucets Wall Mounted AC and Battery Powered Meets ANSI/ASME A112.18.1 M-1989 ADA Compliant Operation 1. A continuous, invisible beam is emitted from the sensor. Model Sensor Type Flow-Rate...
6700C Series 6700C Series 6700C Series Sensor Operated Faucet DC Powered Sensor Operated Mixing Faucet DC Powered Sensor Operated Mixing Faucet Installation Instructions Installation Instructions Installation Instructions ISO 9001 Certified 1. Prior to installation, thoroughly flush all water lines and replace stop washers, if required.
6700C Series 6700C Series Sensor Operated Mixing Faucet Troubleshooting Guide Sensor Operated Mixing Faucet Troubleshooting Guide Normal Operation: When power is connected, the faucet will immediately perform diagnostic function. You will hear a clicking sound and see lights flash. When the user’s hands are placed under the spout, the light will flash once and water will start to flow.
6700C Series 6700C Series Sensor Operated Mixing Faucet Solenoid Valve Cleaning Sensor Operated Mixing Faucet Solenoid Valve Cleaning 1. Turn off water supply at stop valve. 8. Check and clean Filter Screen (#24) in Filter 2. Remove control box (if possible) to gain access Body (#22).
Page 10
6700C Series 6700C Series 6700C Series Sensor Operated Mixing Faucet Sensor Operated Mixing Faucet Sensor Operated Mixing Faucet Control Module Settings Control Module Settings Control Module Settings Settings Control Dipswitches Reset Button Sensor Length Adjuster Shut Off Time Delay (After hands are removed) Shut Off Time Delay (After hands are removed) Factory Preset Factory Preset...