Systems equipped with standard digital control panels

Advertisement

Freeze Protection
If the high-limit sensor detects 40°F at the heater, then all equipment is automatically activated to provide freeze protection. This is a
normal spa function; no corrective action is necessary. The equipment stays on until the sensor detects 45°F at the heater. Freeze
protection is enabled regardless of the status of the spa. In colder climates, an optional additional freeze sensor may be added to
protect against freeze conditions. See your dealer for details.
Diagnostic Messages
No message on display
Power has been cut off to the spa. The control panel will be disabled until power returns. Spa settings will be preserved for
30 days with a battery backup.
Overheat Protection (Spa is deactivated)
DO NOT ENTER THE WATER. If the spa water has reached 112°F, remove the spa cover to cool the water. Overheating
may occur if the filter cycle is set too long. At 110°F, the spa should reset itself. If the high-limit sensor detects 118°F at the
heater, the spa will shut down. When the heater cools to 110°F, press any button to reset the spa. If the spa will not reset,
then shut off power to the spa and call your dealer or service organization.
Flow (Flashing)
Flow of water is inhibited. Call your dealer or service organization.
Flow (Not Flashing)
A pressure switch is not working. Call your dealer or service organization.
Sensor (Spa is deactivated)
The high-limit sensor is not working. Call your dealer or service organization.
Sensor (Spa is deactivated)
The water temperature sensor is not working. Call your dealer or service organization.
Ice
A potential freeze condition is detected. No action is required. The pump(s) will automatically activate regardless of spa
status.
Cool
Water temperature is 20°F or more below the temperature last set. No action is required. Spa is functioning properly.
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner's manual
power connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be
properly installed.
System Options - Activated by Dealer or Service Organization Only!
Temperature control (80°F - 104°F): J17 on 1 pin
Overrange control (80°F - 108°F): J17 on 2 pins
Circulating pump & 24 hour ozone: J6 "B" position
Preset filter; ozone during filter cycle; no circulating pump: J6 "A" position
12/120VAC Light: J12
P/N DCM3S2 12/15/99