System Overview ......................9 3.1.2 Features ........................9 3.1.3 Optional Features ......................10 Front Panel Elements ......................11 3.2.1 CML00 3U / 8HP ......................11 3.2.2 Power entry module and fuse ..................11 3.2.3 Main Power switch....................... 11 3.2.4 Ethernet connector ...................... 12 3.2.5...
Page 4
List of Figures Figure 3-1: CML00 ..........................11 Figure 3-2: Ethernet Connector Pin Assignment ................... 12 Figure 3-3: USB Connector Pin Assignment ..................12 Figure 3-4: interface connector ......................13 Figure 3-5: Protective Earth and Grounding..................15 Figure 3-6: Window “Fans” in SYScontrol ..................... 16 Figure 3-7: Window “Temperature Sensors”...
System name Order number CML00 Controlboard with TCP/IP and USB 1H00004147 230VAC Power supply with power entry for CML00 D575.00373 CML00 Kit. 1H00004146 + D575.00373 with 3U/8HP front panel 1H00004170 1.1 Background Information • IEC 60297-3-101, -102, -103 • PICMG 2.0 R3.0 CPCI Core Specification •...
2 Safety 2.1 Intended Application CML00 are not end-products, so there is no valid approval for this unit. In Order to enable stand-alone functionality, additional elements are required. The completion and final testing of the units have been carried out, or at least supervised, by qualified technicians.
Do not operate a shelf in this condition, as this may cause damage to other equipment. 2.4.6 Electrical Hazards The caution label on the system's rear near the grounding studs shows that you have to create an earth connection because there may be a high leakage current which is considered hazardous. www.hartmann-electronic.com Rev 1.5...
Page 8
High leakage current can cause injuries. Ensure that the system is properly grounded at all times, the following conditions shall be met: • This equipment shall be connected directly to the AC supply system earthing Rev. 1.5 www.hartmann-electronic.com...
2mm high density connector. For standard backplanes (e.g. VME) specific adapters are available. The CML/adapter combination can be inserted into Hartmann electronic standard VME, VPX, cPCI systems, backplanes or power backplanes. An optional alphanumeric display module can be connected to the CML. With this display all measured values can be visualized.
Different Fan types supported (PWM-pulsed Fan or Fan with tachometer signal) • PWM-Signal for external use The system is based on a fast DSP-controller with flexible interface hardware. So it is possible to implement various custom-specific applications. Rev. 1.5 www.hartmann-electronic.com...
3.2 Front Panel Elements 3.2.1 CML00 3U / 8HP Figure 3-1: CML00 Front panel 3U/8HP USB connector VAC Power entry module Status LED Main power switch ON / OFF soft switch Ethernet connector Fuse I / O Connector 3.2.2 Power entry module and fuse The power entry module is provided with an IEC 320-C14 connector, contacted with fuse holder 1 pole.
System power is on, all measurement values are in limit • System switched off because of any failure 3.2.7 ON / OFF Soft Switch The soft switch is used to switch the system power supply (push the switch to the “ON” or position “OFF”). Rev. 1.5 www.hartmann-electronic.com...
There is a 6.3 x 0.8mm PE-flat plug at the auxiliary PSU. This flat plug is only for potential equalization. Grounding is achieved through the protective earth conductor of the power cable! Figure 3-5: Protective Earth and Grounding www.hartmann-electronic.com Rev 1.5...
CML to achieve the requested rotation speed. The nominal fan speed is changeable with the SNMP network commands (crate.fantray.fanNominalSpeed OID) or in SYScontrol window “Global” An automatic fan speed regulation depending on the temperature sensors is also possible. Rev. 1.5 www.hartmann-electronic.com...
If the “sensorFailureThreshold” of any connected sensor is reached, the main power supply of the system is switched off. The controlling result of fan speed is pictured in figure 3.8. www.hartmann-electronic.com Rev 1.5...
Overstepping the “sensorAlarmThreshold” they will switch to their maximum speed. After exceeding the “sensorFailureThrehold” of any connected sensor, the main power supply of the system is switched off. The controlling result of fan speed is pictured in figure 3.9. Rev. 1.5 www.hartmann-electronic.com...
If is it not necessary to cool down the device the fans stand still. After reaching of “sensorWarningThreshold” the behavior of fan control is equal to the linear control mode. The controlling result of fan speed is pictured in figure 3.10. www.hartmann-electronic.com Rev 1.5...
30°C “sensorAlarmThreshold” 45°C “sensorFailureThrehold” 55°C 3.5 Basic Control & Meassurement Signals 8 digital inputs and 8 digital outputs are on the HD-SUB-D26 connector on the front plate. Figure 3-11: High density SUB-D DIO connector 26 Pol SUB-D Rev. 1.5 www.hartmann-electronic.com...
SUB-D Are DIO bits numbered: bit 0 to 7 bit. The CML00 extension is most significant bits (MSB) To example: “hex” F0 to answer “binary” 11110000, “hex” AA to answer “binary” 10101010 3.5.1 Digital Inputs The digital inputs DI1 ... DI8 are standard TTL inputs The inputs can be read by SNMP network commands (crate.signal.digitalInput OID)
The installation software “MUSEcontrolInstall-x.x.x.x.exe” is part of delivery. Then accept the “automatic install the software” selection by clicking “continue” Now the USB driver software be installed. To access your CML00, execute the “MUSEcontrol” application via your start menu. 4.2 The Main Window MUSEcontrol After starting the application “MUSEcontrol”...
CML via the Simple Network Management Protocol. Please see http://net-snmp.sourceforge.net/ for more details. 2. The HEL-CRATE-MIB.txt (or old Version with WIENER-CRATE-MIB.txt) file must be stored somewhere on the PC doing the calls, by default that location should be /usr/share/snmp/mibs. 3. Install software “SYScontrolInstall-x.x.x.x.exe” www.hartmann-electronic.com Rev 1.5...
Figure 5-1: Window “Clobal” in SYScontrol “SYScontrol” visualizes all relevant values such as temperature, voltage, fan speed, network address and system status. You can change all the values needed, such as threshold of temperature, fan speed, or voltages. Rev. 1.5 www.hartmann-electronic.com...
Figure 5-2: Window “Outputs” in SYScontrol For Failure Action set “Ignore” then the errors are ignored, or set “All off” then the system turned off in case of error. Failure action “Channel of” and “Group off” is not valid for CML00. www.hartmann-electronic.com Rev 1.5...
Default network address is 192.168.1.9. For DHCP active, please type 0.0.0.0 5.2.3 Connect devises in your network For search devices connected to your network, please click to “Settings” and then to “Preferences” Figure 5-4: Window “Preferences” in SYScontrol Rev. 1.5 www.hartmann-electronic.com...
For connect to CML00 please write the true network address, or click of the “Search IP” – Button. Figure 5-5: Window “Search” in SYScontrol All CML00 located in the network are displayed. For connection, click on device and “OK” 6 CML setup via “snmp”...
8.1 Technical support and Return for Service Assistance Please return the complete subrack system. For all product returns and support issues, please contact your Hartmann Electronic sales distributor or www.hartmann-electronic.com Please use the original packing material. Shipping without the original packing material might void the warranty.
Page 29
MAILING ADDRESS TELEPHONE AND E-MAIL Hartmann Electronic GMBH +49(0)711139890 Motorstrasse 43 info@hartmann-electronic.com 70499 Stuttgart Germany For further Information about other Hartmann Electronic products, please visit our Internet web site: www.hartmann-electronic.com...