Certification Exhibit FCC ID: TMAELK-6051 IC: 4353A-6051 FCC Rule Part: 15.247 ISED Canada’s Radio Standards Specification: RSS-247 TÜV SÜD Project Number: 72126638 Manufacturer: ELK Products, Inc. Model: ELK-6051 Manual 2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235...
Page 2
Wireless Carbon Monoxide Alarm ELK-6051 ELK-6051 Wireless Carbon Monoxide Alarm Instruction Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Alarm. This booklet should be regarded as part of the product.
Table of Contents page Read This First ..............Carbon Monoxide – The Silent Killer ........Where to Place CO Alarms ..........Installation ................Testing / Monitoring & Maintenance ........What to do when the alarm sounds ........How to Protect your Family ..........Technical Specification ............
1. Read This First • Congratulations on becoming the owner of an Elk Carbon Monoxide Alarm. This product is designed to help protect you and your household from the dangerous effects of Carbon Monoxide- the silent killer. • The Carbon Monoxide Alarm (CO Alarm) is powered up by carefully rotating it onto the mounting plate which activates the on/off switch.
Page 5
2. Carbon Monoxide – The Silent Killer 2.1 What is Carbon Monoxide? Many people are killed each year, and many more suffer ill health from Carbon Monoxide (CO) poisoning. CO is an invisible, odorless, tasteless and extremely toxic gas. It is produced by appliances and vehicles burning fuels, such as coal, oil, natural/bottled gas, paraffin, wood, petrol, diesel, charcoal etc.
Page 6
2.3 Symptoms of Carbon Monoxide Poisoning Table A Concentration of CO in Air Inhalation Time (approx) and Symptoms Developed The maximum allowable concentration for continuous exposure in any 8 hour period according to OSHA *. Slight headache after 1.5 hours. Slight headache, fatigue, dizziness, nausea after 2-3 hours.
Page 7
Table B: CO Alarm Response Red Light Horn/Sounder CO Gas Level 0 ppm to < 50 ppm OFF * OFF* On within 60-240 >50 ppm 1 flash every 3 secs. minutes (typ 90 minutes) On within 10-50 minutes >110 ppm 2 flashes every 3 secs.
Page 8
Pre-Alarm (before horn sounds): When the Alarm detects over 50 ppm CO the red light flashes in accordance with Table B. This helps locate CO leaks as the unit gives an indication straight away. (Without this feature the CO level would need to be at 50 ppm CO for typically 72 minutes for an alarm sound to be given).
Table C: CO Alarm Memory Indicators Red Light Response CO Gas Level 24 Hours On Demand (Button Press) ppm > 50 ppm 1 flashes every 50 sec 1 flashes ppm > 1 10 ppm 2 flashes every 50 sec 2 flashes ppm >...
Page 10
IMPORTANT! Specific requirements for Carbon Monoxide Alarm installation vary from state to state and from region to region. Check with your local Fire Department for current requirements in your area. 3.1 Ideally a Carbon Monoxide Alarm should be installed in: - Every room containing a fuel burning appliance, and - Remote rooms where occupants spend a considerable amount of time - Every bedroom.
Page 11
300mm CO Alarm 150mm 1.5 to 3 m DEAD AIR DON'T LOCATE HERE 1.5 to 3 m Figure 1 Location in room with a fuel burning appliance...
Page 12
CO Alarm CO Alarm about 1 to 2m Figure 2 Figure 3 Location in rooms with sloped Location in bedrooms & other ceilings, the CO Alarm should be rooms remote from the appliance located at the high side of the room (i.e.
Page 13
3.2 Unsuitable Locations Do not place the CO Alarm in any of the following areas. (1) In the immediate vicinity of a cooking appliance (keep it at least 1 metre horizontally from it). (2) Outside the building. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area.
Page 14
3.31 If locating the CO Alarm in a room with a fuel burning appliance (see figure 1) • If it is mounted on a wall, it should be located at a height greater than the height of any door or window but still be at least 150mm from the ceiling. •...
4. Installation Warning: The Installations of this apparatus should not be used for a substitute for proper installation, use and maintenance of fuel burning appliances including appropriate ventilation and exhaust systems. 4.1 Installation Procedure 1. Select a location complying with the advice in Section 3.
Page 16
7. Carefully line up the Alarm on the base, gentle press home & twist on. (see figure 4) This Light connects the batteries and the red, amber & green Amber Light lights will immediately flash in sequence to show they are working. Green Light 8.
It is possible to further secure or tamperproof the Alarm by using a No.2 or No.4 (2 to 3mm diameter - not supplied) self-tapping screw 6 to 8mm long to firmly lock the Alarm and its mounting plate together (see figure 7). 5.
Page 18
Visual Status and Self-Test The CO alarm will self-check itself and give a status update every 50 seconds if there are any problems. The status of the Alarm can also be checked on demand by using the test button. The table below shows the visual status response to both the self-check and on demand testing.
Page 19
Use the narrow nozzle of a vacuum cleaner to remove fluff and other contamination from the cover slots and gas entry holes. Caution: Do not paint the CO Alarm. Remove the CO Alarm when decorating. Do not allow water or dust to contaminate the Alarm.
Page 20
AudioLINK AudioLINK feature allows an authorized person to download information from the Alarm through by way of a mobile App. For more information on using this feature, please refer to the relevant section on www.elkproducts.com. Warning! Constant exposures to high or low temperatures or high humidity may reduce battery life.
the power switch to the ON position (See fig 9). Fill Position a suitable size plastic bag with smoke from the joss stick or cigarette. Insert the Alarm into the smoke filled bag and seal it closed. Within seconds, the red light will begin to flash (as per Table B) to confirm that the Alarm has detected the CO gas in the bag.
4) After following steps 1-3, if your Alarm reactivates within a 24 hour period, repeat steps 1-3 and call a qualified appliance technician (Telephone Number) to investigate for sources of CO from fuel burning equipment and appliances, and inspect for proper operation of this equipment.
Page 23
- Family members (including pets) exhibiting the “flu-like” symptoms of CO poisoning described above. If any of these signs are present get the appliance checked out by an expert before further use. If family members are ill get medical help. (2) Choose all appliances and vehicles which burn fossil fuels such as coal, oil, natural/bottled gas, paraffin, wood, petrol, diesel, charcoal etc.
in modern houses reduces ventilation and can allow dangerous gases to build up. (10) Install CO Alarms in all the areas recommended in this booklet. (11) Recognize that CO poisoning may be the cause when family members suffer from “flu-like” symptoms when at home but feel better when they are away for extended periods.
Acts of God, such as fire, flood, hurricanes and tornadoes. If this Alarm should become defective within the guarantee period, it must be returned to Elk Products, with proof of purchase, carefully packaged, with the problem clearly stated. We shall at our discretion repair or replace the faulty unit.
Some states or jurisdictions do not allow the limitation or exclusion of incidental or consequential damages, or limitations on how long an implied warranty last so the above limitation may not apply to you. Do not interfere with the Alarm or attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user to shock or fire hazards.
Page 27
(4) CO Alarms don’t last indefinitely. CO Alarms are sophisticated electronic devices with many parts. Although the Alarm and its component parts have undergone stringent tests, and are designed to be very reliable, it is possible that parts can fail. Therefore, you should test your CO Alarm weekly.
WARNING: THIS CO ALARM IS DESIGNED TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT CONSULT A MEDICAL PRACTITIONER. 12. Troubleshooting ALARM DOES NOT WORK WITH THE TEST BUTTON: (1) Wait 15 seconds after connecting the power before button testing.
(7) Press the test/hush button to silence the alarm. If the unit continues to sound it is possibly defective and should be replaced (see section 9 “Getting the CO Alarm Serviced”). ELK-6051 Indicator Summary Normal Operation Red LED Amber LED...
Page 30
ELK-6051 Service Diagnostics Diagnostics Modes Action Red LED Yellow LED Sounder Action Fault Checks Replace Batteries Low battery Press & hold button 1 flash 1 beep with flash 2 flashes 2 beeps with flashes Replace Alarm Faulty Sensor Press & hold button End of Life (EOL) Press &...
(2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: ELK PRODUCTS IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATION NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
Page 32
: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ELK-6051 Wireless CO Detector FCC ID: TMAELK-6051 IC: 4353A-6051 This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment.